Benzene, 1,2,3,4-tetrachloro-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Condensed phase thermochemistry data

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Hussein Y. Afeefy, Joel F. Liebman, and Stephen E. Stein

Quantity Value Units Method Reference Comment
Δcsolid-2642.22 ± 0.74kJ/molCcrPlatonov and Simulin, 1985 

IR Spectrum

Go To: Top, Condensed phase thermochemistry data, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compiled by: Coblentz Society, Inc.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director


Mass spectrum (electron ionization)

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Chuck Anderson, Aldrich Chemical Co.
NIST MS number 107311

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillarySE-30160.1388.0Santiuste, Harangi, et al., 2003 
CapillaryHP-5120.1385.4Santiuste, Harangi, et al., 2003 
CapillaryHP-5120.1385.3Santiuste J.M. and Takacs J.M., 200360. m/0.25 mm/0.25 μm, N2
CapillaryHP-5140.1402.3Santiuste J.M. and Takacs J.M., 200360. m/0.25 mm/0.25 μm, N2
CapillarySPB-1140.1370.Vezzani, Bertocchi, et al., 199830. m/0.32 mm/0.25 μm
CapillaryDB-5110.1377.18Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillaryDB-570.1343.88Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillaryDB-590.1359.50Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2
CapillarySE-30160.1366.Evans and Haken, 1989Column length: 25. m; Column diameter: 0.32 mm
CapillarySE-30160.1388.Tarjan, Nyiredy, et al., 1989 
CapillarySE-30120.1366.Haken and Korhonene, 1983N2; Column length: 25. m; Column diameter: 0.22 mm
CapillarySE-30140.1371.Haken and Korhonene, 1983N2; Column length: 25. m; Column diameter: 0.22 mm
CapillarySE-30160.1388.Haken and Korhonene, 1983N2; Column length: 25. m; Column diameter: 0.22 mm

Kovats' RI, polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
CapillaryZB-Wax120.1914.1Pérez-Parajón, Santiuste, et al., 200460. m/0.25 mm/0.25 μm
CapillaryZB-Wax140.1938.0Pérez-Parajón, Santiuste, et al., 200460. m/0.25 mm/0.25 μm
CapillaryZB-Wax160.1968.2Pérez-Parajón, Santiuste, et al., 200460. m/0.25 mm/0.25 μm
CapillaryCarbowax 20M160.1908.Haken and Korhonene, 1983N2; Column length: 22. m; Column diameter: 0.3 mm
CapillaryCarbowax 20M180.1941.Haken and Korhonene, 1983N2; Column length: 22. m; Column diameter: 0.3 mm

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-51352.40Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-51362.21Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-51369.92Gerbino, Garbarino, et al., 199630. m/0.53 mm/1.5 μm, N2, 2. K/min; Tstart: 50. C
CapillaryDB-11362.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 100. C @ 0. min, 10. K/min
CapillaryDB-11352.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 100. C @ 0. min, 5. K/min
CapillaryDB-11353.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 50. C @ 0. min, 10. K/min
CapillaryDB-11342.Gerbino and Castello, 199530. m/0.235 mm/0.25 μm, N2, 50. C @ 0. min, 5. K/min

Van Den Dool and Kratz RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
PackedSE-301345.Peng, Ding, et al., 1988Supelcoport; Chromosorb; Column length: 3.05 m; Program: 40C(5min) => 10C/min => 200C or 250C (60min)

Van Den Dool and Kratz RI, polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryDB-Wax1951.96Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 10. K/min; Tstart: 100. C
CapillaryDB-Wax1931.77Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 5. K/min; Tstart: 100. C
CapillaryDB-Wax1944.44Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 10. K/min; Tstart: 50. C
CapillaryDB-Wax1920.95Gerbino and Castello, 199530. m/0.235 mm/0.5 μm, N2, 5. K/min; Tstart: 50. C

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-51383.Zenkevich, Moeder, et al., 200430. m/0.25 mm/0.25 μm, Helium, 50. C @ 3. min, 3. K/min, 280. C @ 20. min
CapillaryUltra-11336.Okumura, 199125. m/0.32 mm/0.25 μm, He, 3. K/min; Tstart: 80. C; Tend: 260. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryMethyl Silicone1366.Yu and Zazhi, 2005Program: not specified
CapillaryCP Sil 21375.Fuhrer, Deissler, et al., 199755. m/0.25 mm/0.25 μm, N2; Program: 40C(3min) => 20C/min => 80C => 2C/min => 240C(45min)
CapillaryPolydimethyl siloxanes1355.Zenkevich and Chupalov, 1996Program: not specified
CapillaryPTE-51411.Nakano, Fujimori, et al., 199225. m/0.20 mm/0.33 μm; Program: 50 0C (2 min) 30 0C/min -> 200 0C 8 0C/min -> 280 0C (10 min)

Lee's RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP5-MS237.Vrana, Paschke, et al., 200530. m/0.25 mm/0.25 μm, Helium, 50. C @ 5. min, 5. K/min, 280. C @ 10. min
CapillaryDB-5219.2Viau, Studak, et al., 1984Helium, 4. K/min; Column length: 30. m; Column diameter: 0.32 mm; Tstart: 90. C; Tend: 250. C

References

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Platonov and Simulin, 1985
Platonov, V.A.; Simulin, Yu.N., Determination of the standard enthalpies of formation of polychlorobenzenes. III. The standard enthalpies of formation of mono-1,2,4- and 1,3,5-tri-, and 1,2,3,4- and 1,2,3,5-tetrachlorobenzenes, Russ. J. Phys. Chem. (Engl. Transl.), 1985, 59, 179-181. [all data]

Santiuste, Harangi, et al., 2003
Santiuste, J.M.; Harangi, J.; Takács, J.M., Mosaic increments for predicting the gas chromatographic retention data of the chlorobenzenes, J. Chromatogr. A, 2003, 1002, 1-2, 155-168, https://doi.org/10.1016/S0021-9673(03)00736-2 . [all data]

Santiuste J.M. and Takacs J.M., 2003
Santiuste J.M.; Takacs J.M., Relationships between retention data of benzene and chlorobenzenes with their physico-chemical properties and topological indices, Chromatographia, 2003, 58, 87-96. [all data]

Vezzani, Bertocchi, et al., 1998
Vezzani, S.; Bertocchi, A.; Moretti, P.; Castello, G., Prediction of the gas chromatographic retention values of chlorobenzenes on different station phases by using structure-retention correlations, J. Chromatogr. A, 1998, 803, 1-2, 211-218, https://doi.org/10.1016/S0021-9673(97)01281-8 . [all data]

Gerbino, Garbarino, et al., 1996
Gerbino, T.C.; Garbarino, G.; Petit-Bon, P., Programmed temperature retention indices: calculation of linear programmed temperature retention indices of halogenated benzenes from isothermal data, Ann. Chim. (Rome), 1996, 86, 63-75. [all data]

Evans and Haken, 1989
Evans, M.B.; Haken, J.K., Dispersion and selectivity indices in gas chromatography. IV. Chlorinated aromatic compounds, J. Chromatogr., 1989, 468, 373-382, https://doi.org/10.1016/S0021-9673(00)96332-5 . [all data]

Tarjan, Nyiredy, et al., 1989
Tarjan, G.; Nyiredy, Sz.; Gyor, M.; Lombosi, E.R.; Lombosi, T.S.; Budahegyi, M.V.; Meszaros, S.Y.; Takacs, J.M., Review. Thirtieth Anniversary of the Retention Index According to Kovats in Gas-Liquid Chromatography, J. Chromatogr., 1989, 472, 1-92, https://doi.org/10.1016/S0021-9673(00)94099-8 . [all data]

Haken and Korhonene, 1983
Haken, J.K.; Korhonene, I.O.O., Retention increments of isomeric chlorobenzenes, J. Chromatogr., 1983, 265, 323-327, https://doi.org/10.1016/S0021-9673(01)96727-5 . [all data]

Pérez-Parajón, Santiuste, et al., 2004
Pérez-Parajón, J.M.; Santiuste, J.M.; Takács, J.M., Sensitivity of the methylbenzenes and chlorobenzenes retention index to column temperature, stationary phase polarity, and number and chemical nature of substituents, J. Chromatogr. A, 2004, 1048, 2, 223-232, https://doi.org/10.1016/j.chroma.2004.07.028 . [all data]

Gerbino and Castello, 1995
Gerbino, T.C.; Castello, G., Prediction of programmed temperature retention indices on capillary columns of different polarities, J. Chromatogr. A, 1995, 699, 1-2, 161-171, https://doi.org/10.1016/0021-9673(95)00024-H . [all data]

Peng, Ding, et al., 1988
Peng, C.T.; Ding, S.F.; Hua, R.L.; Yang, Z.C., Prediction of Retention Indexes I. Structure-Retention Index Relationship on Apolar Columns, J. Chromatogr., 1988, 436, 137-172, https://doi.org/10.1016/S0021-9673(00)94575-8 . [all data]

Zenkevich, Moeder, et al., 2004
Zenkevich, I.G.; Moeder, M.; Koeller, G.; Schrader, S., Using new structurally related additive schemes in the precalculation of gas chromatographic retention indices of polychlorinated hydroxybiphenyls on HP-5 stationary phase, J. Chromatogr. A, 2004, 1025, 2, 227-236, https://doi.org/10.1016/j.chroma.2003.10.106 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]

Yu and Zazhi, 2005
Yu, H.; Zazhi, J., Relationship between chromatogram retention index and toxicity of chlorinated phenols and chlorinated benzenes to Guppy, J. Enviropn. Health (Chinese), 2005, 22, 6, 441-444. [all data]

Fuhrer, Deissler, et al., 1997
Fuhrer, U.; Deissler, A.; Schreitmuller, J.; Ballschmiter, K., Analysis of Halogenated Methoxybenzenes and Hexachlorobenzene (HCB) in the Picogram m-3 Range in Marine Air, Chromatographia, 1997, 45, 1, 414-427, https://doi.org/10.1007/BF02505594 . [all data]

Zenkevich and Chupalov, 1996
Zenkevich, I.G.; Chupalov, A.A., New Possibilities of Chromato Mass Pectrometric Identification of Organic Compounds Using Increments of Gas Chromatographic Retention Indices of Molecular Structural Fragments, Zh. Org. Khim. (Rus.), 1996, 32, 5, 656-666. [all data]

Nakano, Fujimori, et al., 1992
Nakano, T.; Fujimori, K.; Takaishi, Y.; Okuno, T., GC/MS-SIM analysis of polychlorobenzenes, polychlorophenols and polychloronaphthalenes, Report of the Environmental Science Institute of Hyogo Prefecture, 1992, 24, 30-37. [all data]

Vrana, Paschke, et al., 2005
Vrana, B.; Paschke, H.; Paschke, A.; Popp, P.; Schuurmann, G., Performance of semipermeable membrane devices for sampling of organic contaminants in groun water, J. Envirom. Monit., 2005, 7, 5, 500-508, https://doi.org/10.1039/b411645c . [all data]

Viau, Studak, et al., 1984
Viau, A.C.; Studak, S.M.; Karasek, F.W., Comparative analysis of hazardous compounds on flu-ash from municipal waste incineration by gas chromatography / mass spectrometry, Can. J. Chem., 1984, 62, 11, 2140-2145, https://doi.org/10.1139/v84-366 . [all data]


Notes

Go To: Top, Condensed phase thermochemistry data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, References