Thiophene, 2,3-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PONAPONACP-Sil 5CP-Sil 5CP Sil 5 CB
Column length (m) 50.50.25.25.25.
Carrier gas N2 HeliumHeliumHe
Substrate      
Column diameter (mm) 0.200.200.320.320.32
Phase thickness (μm) 0.500.500.450.450.45
Tstart (C) 35.30.0.0.50.
Tend (C) 170.150.300.300.300.
Heat rate (K/min) 2.2.3.3.3.
Initial hold (min)   5.5. 
Final hold (min)      
I 874.867.868.869.868.
ReferenceYang, Wang, et al., 2004Yang, Wang, et al., 2003Damste, van Dalen, et al., 1988Damste, van Dalen, et al., 1988Damste, Kock-van Dalen, et al., 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase CP Sil 5 CB
Column length (m) 25.
Carrier gas He
Substrate  
Column diameter (mm) 0.32
Phase thickness (μm) 0.45
Tstart (C) 50.
Tend (C) 300.
Heat rate (K/min) 3.
Initial hold (min)  
Final hold (min)  
I 869.
ReferenceDamste, Kock-van Dalen, et al., 1988
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Yang, Wang, et al., 2004
Yang, Y.; Wang, Z.; Zong, B.; Yang, H., Determination of sulfur compounds in fluid catalytic cracking gasoline by gas chromatography with a sulfur chemiluminiscence detector, Chin. J. Chromatogr., 2004, 22, 3, 216-219. [all data]

Yang, Wang, et al., 2003
Yang, Y.-T.; Wang, Z.; Han. J.-H.; Tian, H.-P.; Yang, H.-Y., Determination of sulfur compounds in gasoline fraction of microreactor products by gas chromatography - Atomic emission detector, Petrochemical Technology (Shiyou Huagong), 2003, 32, 11, 995-998. [all data]

Damste, van Dalen, et al., 1988
Damste, J.S.S.; van Dalen, A.C.K.; de Leeuw, J.W.; Schenck, P.A., Identification of homologous series of alkylated thiophenes, thiolanes, thianes and benzothiophenes present in pyrolisates of sulfur-rich kerogenes, J. Chromatogr., 1988, 435, 435-452, https://doi.org/10.1016/S0021-9673(01)82208-1 . [all data]

Damste, Kock-van Dalen, et al., 1988
Damste, J.S.S.; Kock-van Dalen, A.C.; de Leeuw, J.W.; Schenk, P.A., Identification of homologous series of alkylated thiophenes, thiolanes, thianes and benzothiophenes present in pyrolysates of sulphur-rich kerogens, J. Chromatogr., 1988, 435, 435-452, https://doi.org/10.1016/S0021-9673(01)82208-1 . [all data]