Hexanedioic acid, dimethyl ester
- Formula: C8H14O4
- Molecular weight: 174.1944
- IUPAC Standard InChIKey: UDSFAEKRVUSQDD-UHFFFAOYSA-N
- CAS Registry Number: 627-93-0
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Adipic acid, dimethyl ester; Dimethyl adipate; Dimethyl hexanedioate; Methyl adipate; 1,6-Dimethylhexanedioate; Dimethyl ester of hexanedioic acid; Hexanedioic acid, methyl ester
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Kovats' RI, non-polar column, isothermal
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | SE-54 | SE-54 | SE-54 | Ultra-1 | Ultra-1 |
Column length (m) | 15. | 15. | 15. | 25. | 25. |
Carrier gas | Ar | Ar | Ar | N2 | N2 |
Substrate | |||||
Column diameter (mm) | 0.28 | 0.28 | 0.28 | 0.20 | 0.20 |
Phase thickness (μm) | 2.4 | 2.4 | 2.4 | 0.32 | 0.32 |
Temperature (C) | 140. | 160. | 180. | 100. | 125. |
I | 1243. | 1242. | 1241. | 1207. | 1205. |
Reference | Grigor'eva, Vasil'ev, et al., 1993 | Grigor'eva, Vasil'ev, et al., 1993 | Grigor'eva, Vasil'ev, et al., 1993 | Herrmann, Dufka, et al., 1986 | Herrmann, Dufka, et al., 1986 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Packed |
---|---|---|---|
Active phase | Ultra-1 | Ultra-1 | SE-30 |
Column length (m) | 25. | 25. | 2. |
Carrier gas | N2 | N2 | |
Substrate | |||
Column diameter (mm) | 0.20 | 0.20 | |
Phase thickness (μm) | 0.32 | 0.32 | |
Temperature (C) | 150. | 175. | 220. |
I | 1204. | 1202. | 1234. |
Reference | Herrmann, Dufka, et al., 1986 | Herrmann, Dufka, et al., 1986 | Zulaïca and Guiochon, 1963 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Kovats' RI, non-polar column, isothermal, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Grigor'eva, Vasil'ev, et al., 1993
Grigor'eva, D.N.; Vasil'ev, A.V.; Golovnya, R.V.,
Effect of the temperature on the retention indices in homologous series of bifunctional compounds under capillary gas chromatography conditions,
J. Anal. Chem. USSR (Engl. Transl.), 1993, 48, 7, 817-822. [all data]
Herrmann, Dufka, et al., 1986
Herrmann, F.; Dufka, O.; Churacek, J.,
Fused-Silica Capillary Gas Chromatography-Mass Spectrometry of Some Dicarboxylic Acids Present in Condensation-Type Polymers I. Dimethyl Esters,
J. Chromatogr., 1986, 360, 79-88, https://doi.org/10.1016/S0021-9673(00)91653-4
. [all data]
Zulaïca and Guiochon, 1963
Zulaïca, J.; Guiochon, G.,
Séparation et identification de di-esters aliphatiques et aromatiques et de trimesters phosphoriques par chromatographie en phase gazeuse,
Bull. Soc. Chim. Fr., 1963, 6, 1242-1252. [all data]
Notes
Go To: Top, Kovats' RI, non-polar column, isothermal, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.