2-Hexanol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30OV-101OV-101OV-101OV-101
Column length (m) 40.20.20.20.20.
Carrier gas      
Substrate      
Column diameter (mm) 0.350.50.50.50.5
Phase thickness (μm) 0.35    
Temperature (C) 100.150.180.150.180.
I 780.3777.7787.6775.9778.5
ReferenceTudor, 1997Cha and Lee, 1994Cha and Lee, 1994Cha and Lee, 1994Cha and Lee, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPackedPackedPacked
Active phase OV-101OV-101Apiezon LApiezon LSE-30
Column length (m) 100.100.  1.
Carrier gas N2N2  Ar
Substrate   Celite 545Celite 545Chromosorb W AW DMCS HP (80-100 mesh)
Column diameter (mm) 0.270.27   
Phase thickness (μm)      
Temperature (C) 80.90.120.160.100.
I 803.1804.4766.775.787.
ReferenceBoneva, 1987Boneva, 1987Bogoslovsky, Anvaer, et al., 1978Bogoslovsky, Anvaer, et al., 1978Pías and Gascó, 1975
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPacked
Active phase SE-30SE-30Squalane
Column length (m) 1.1. 
Carrier gas ArAr 
Substrate Chromosorb W AW DMCS HP (80-100 mesh)Chromosorb W AW DMCS HP (80-100 mesh)Chromosorb G
Column diameter (mm)    
Phase thickness (μm)    
Temperature (C) 120.140.50.
I 786.783.766.
ReferencePías and Gascó, 1975Pías and Gascó, 1975Mira and Sanchez, 1970
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Tudor, 1997
Tudor, E., Temperature dependence of the retention index for perfumery compounds on a SE-30 glass capillary column. I. Linear equations, J. Chromatogr. A, 1997, 779, 1-2, 287-297, https://doi.org/10.1016/S0021-9673(97)00453-6 . [all data]

Cha and Lee, 1994
Cha, K.-W.; Lee, D.-J., Prediction of retention indices of various compounds in gas-liquid chromatography, J. Korean Chem. Soc., 1994, 38, 2, 108-120, retrieved from http://journal.kcsnet.or.kr/publi/dh/dh94n2/108.pdf. [all data]

Boneva, 1987
Boneva, S., Gas Chromatographic Retention Indices for C6 Alkanols on OV-101 and Carbowax 20M Capillary Columns, Chromatographia, 1987, 23, 1, 50-52, https://doi.org/10.1007/BF02310419 . [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Pías and Gascó, 1975
Pías, J.B.; Gascó, L., GC Retention Data of Alcohols and Benzoyl Derivatives of Alcohols, J. Chromatogr. - Chrom. Data, 1975, d14-d16. [all data]

Mira and Sanchez, 1970
Mira, J.M.; Sanchez, L.G., Polarity of the Gas Chromatographic Stationary Phases and Retention Indices of Aliphatic Esters, Ketones and Alcohols, Anal. Chim. Acta., 1970, 50, 2, 315-321, https://doi.org/10.1016/0003-2670(70)80071-X . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References