Cyclohexane, 1,4-dimethyl-, cis-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHHP-5 MSSqualaneSqualaneSqualane
Column length (m) 100.30.100.100.100.
Carrier gas HeliumHelium   
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.500.25   
Tstart (C) 20.50.   
Tend (C) 220.280.   
Heat rate (K/min) 15.4.0.10.20.4
Initial hold (min) 15.    
Final hold (min) 30.    
I 795.804.805.2807.2810.1
ReferenceSupelco, 2012Zhao, Zeng, et al., 2009Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPacked
Active phase SqualaneSqualaneSqualaneApiezon L
Column length (m) 100.100.100.2.
Carrier gas     
Substrate    Chromosorb G-AW-DMCS
Column diameter (mm) 0.250.250.25 
Phase thickness (μm)     
Tstart (C)    25.
Tend (C)     
Heat rate (K/min) 0.60.81.10.
Initial hold (min)     
Final hold (min)     
I 812.4814.3816.0761.
ReferenceKrupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Dahlmann, Köser, et al., 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Supelco, 2012
Supelco, CatalogNo. 24160-U, Petrocol DH Columns. Catalog No. 24160-U, 2012, retrieved from http://www.sigmaaldrich.com/etc/medialib/docs/Supelco/Datasheet/1/w97949.Par.0001.File.tmp/w97949.pdf. [all data]

Zhao, Zeng, et al., 2009
Zhao, C.; Zeng, Y.; Wan, M.; Li, R.; Liang, Y.; Li, C.; Zeng, Z.; Chau, F.-T., Comparative analysis of essential oils from eight herbal medicines with pungent flavor and cool nature by GC-MS and chemometric resolution methods, J. Sep. Sci., 2009, 32, 4, 660-670, https://doi.org/10.1002/jssc.200800484 . [all data]

Krupcik, Cellar, et al., 1986
Krupcik, J.; Cellar, P.; Repka, D.; Garaj, J.; Guiochon, G., Use of Kováts retention indices for characterization of solutes in linear temperature-programmed capillary gas-liquid chromatography, J. Chromatogr., 1986, 351, 111-121, https://doi.org/10.1016/S0021-9673(01)83477-4 . [all data]

Dahlmann, Köser, et al., 1979
Dahlmann, G.; Köser, H.J.K.; Oelert, H.H., Multiple korrelation von retentionsindizes, Chromatographia, 1979, 12, 10, 665-671, https://doi.org/10.1007/BF02302943 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References