NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSE-30SE-30SE-30
Column length (m) 100.100.15.15.100.
Carrier gas HeHeN2N2 
Substrate      
Column diameter (mm)   0.250.250.5
Phase thickness (μm)      
Temperature (C) 106.96.70.70.130.
I 982.979.980.5965.91000.
ReferenceKugucheva and Mashinsky, 1983Kugucheva and Mashinsky, 1983Tóth, 1983Tóth, 1983Bredael, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SqualaneSqualaneSqualaneSqualane
Column length (m) 100.50.50.50.50.
Carrier gas  N2N2  
Substrate      
Column diameter (mm) 0.50.250.250.250.25
Phase thickness (μm)      
Temperature (C) 80.86.96.86.96.
I 985.978.6980.3978.6980.3
ReferenceBredael, 1982Macák, Nabivach, et al., 1982Macák, Nabivach, et al., 1982Nabivach, Bur'yan, et al., 1978Nabivach, Bur'yan, et al., 1978
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase SE-30SE-30SE-30
Column length (m) 25.525.525.5
Carrier gas HeHeHe
Substrate    
Column diameter (mm) 0.50.50.5
Phase thickness (μm)    
Temperature (C) 65.65.65.
I 977.5977.6977.9
ReferenceSvob, Deur-Siftar, et al., 1974Svob and Deur-Siftar, 1974Svob and Deur-Siftar, 1974
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Kugucheva and Mashinsky, 1983
Kugucheva, E.E.; Mashinsky, V.I., Retention Indices of Aromatic Hydrocarbons on Capillary Columns with Squalan and Polyphenyl Ether, Zh. Anal. Khim. (Rus), 1983, 38, 11, 2023-2026. [all data]

Tóth, 1983
Tóth, T., Use of capillary gas chromatography in collecting retention and chemical information for the analysis of complex petrochemical mixtures, J. Chromatogr., 1983, 279, 157-165, https://doi.org/10.1016/S0021-9673(01)93614-3 . [all data]

Bredael, 1982
Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1982, 5, 6, 325-328, https://doi.org/10.1002/jhrc.1240050610 . [all data]

Macák, Nabivach, et al., 1982
Macák, J.; Nabivach, V.; Buryan, P.; Sindler, S., Dependence of retention indices of alkylbenzenes on their molecular structure, J. Chromatogr., 1982, 234, 2, 285-302, https://doi.org/10.1016/S0021-9673(00)81867-1 . [all data]

Nabivach, Bur'yan, et al., 1978
Nabivach, V.M.; Bur'yan, P.; Matsak, I., Retention indices of aromatic hydrocarbons on a squalane capillary column, Zh. Anal. Khim., 1978, 33, 7, 1108-1113. [all data]

Svob, Deur-Siftar, et al., 1974
Svob, V.; Deur-Siftar, D.; Cramers, C.A., Mechanisms of the thermal degradation of alkylbenzenes, J. Chromatogr., 1974, 91, 659-675, https://doi.org/10.1016/S0021-9673(01)97946-4 . [all data]

Svob and Deur-Siftar, 1974
Svob, V.; Deur-Siftar, D., Kovats Retention Indices in the Identification of Alkylbenzene Degradation Products, J. Chromatogr., 1974, 91, 677-689, https://doi.org/10.1016/S0021-9673(01)97947-6 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References