Benzene, 1-ethyl-4-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHDB-5DB-5DB-5DB-5
Column length (m) 50.30.30.30.30.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.50.250.250.251.
Tstart (C) 35.40.40.40.50.
Tend (C) 200.310.310.310.200.
Heat rate (K/min) 3.2.4.6.2.5
Initial hold (min) 10.    
Final hold (min) 10.    
I 954.2956.3960.0962.4969.7
ReferenceCensullo, Jones, et al., 2003Song, Lai, et al., 2003Song, Lai, et al., 2003Song, Lai, et al., 2003Xu, van Stee, et al., 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101PONAPONADB-5DB-5
Column length (m) 80.50.50.30.30.
Carrier gas N2  HeHe
Substrate      
Column diameter (mm) 0.220.20.20.250.25
Phase thickness (μm)  0.50.50.250.25
Tstart (C) 30.35.35.40.40.
Tend (C) 130.220.220.310.310.
Heat rate (K/min) 1.1.1.2.4.
Initial hold (min)  0.50.5  
Final hold (min)  8.8.  
I 948.9945.1952.2956.3960.
ReferenceYin, Liu, et al., 2001Martos, Saraullo, et al., 1997Martos, Saraullo, et al., 1997Lai and Song, 1995Lai and Song, 1995
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5Ultra-1Petrocol DHPetrocol DHPetrocol DH
Column length (m) 30. 100.100.100.
Carrier gas He HeHeHe
Substrate      
Column diameter (mm) 0.25 0.250.250.25
Phase thickness (μm) 0.25 0.50.50.5
Tstart (C) 40.-40.30.30.30.
Tend (C) 310.230.220.220.220.
Heat rate (K/min) 6.4.1.1.1.
Initial hold (min)      
Final hold (min)      
I 962.4946.948.48948.9949.
ReferenceLai and Song, 1995Olson, Sinkevitch, et al., 1992White, Douglas, et al., 1992White, Douglas, et al., 1992White, Hackett, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase DB-5HP-1HP-1HP-1
Column length (m) 15.25.25.25.
Carrier gas HeN2N2N2
Substrate     
Column diameter (mm) 0.530.20.20.2
Phase thickness (μm) 1.5   
Tstart (C) 40.30.30.30.
Tend (C) 90.   
Heat rate (K/min) 4.10.2.5.
Initial hold (min)    5.
Final hold (min)     
I 957.950.8946.3945.1
ReferenceMorinaga, Hara, et al., 1990Bangjie, Xijian, et al., 1987Bangjie, Xijian, et al., 1987Bangjie, Xijian, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Censullo, Jones, et al., 2003
Censullo, A.C.; Jones, D.R.; Wills, M.T., Speciation of the volatile organic compounds (VOCs) in solventborne aerosol coatings by solid phase microextraction-gas chromatography, J. Coat. Technol., 2003, 75, 936, 47-53, https://doi.org/10.1007/BF02697922 . [all data]

Song, Lai, et al., 2003
Song, C.; Lai, W.-C.; Madhusudan Reddy, K.; Wei, B., Chapter 7. Temperature-programmed retention indices for GC and GC-MS of hydrocarbon fuels and simulated distillation GC of heavy oils in Analytical advances for hydrocarbon research, Hsu,C.S., ed(s)., Kluwer Academic/Plenum Publishers, New York, 2003, 147-193. [all data]

Xu, van Stee, et al., 2003
Xu, X.; van Stee, L.L.P.; Williams, J.; Beens, J.; Adahchour, M.; Vreuls, R.J.J.; Brinkman, U.A.Th.; Lelieveld, J., Comprehensive two-dimensional gas chromatography (GC×GC) measurements of volatile organic compounds in the atmosphere, Atmos. Chem. Phys., 2003, 3, 3, 665-682, https://doi.org/10.5194/acp-3-665-2003 . [all data]

Yin, Liu, et al., 2001
Yin, C.; Liu, W.; Li, Z.; Pan, Z.; Lin, T.; Zhang, M., Chemometrics to chemical modeling: structural coding in hydrocarbons and retention indices of gas chromatography, J. Sep. Sci., 2001, 24, 3, 213-220, https://doi.org/10.1002/1615-9314(20010301)24:3<213::AID-JSSC213>3.0.CO;2-4 . [all data]

Martos, Saraullo, et al., 1997
Martos, P.A.; Saraullo, A.; Pawliszyn, J., Estimation of air/coating distribution coefficients for solid phase microextraction using retention indexes from linear temperature-programmed capillary gas chromatography. Application to the sampling and analysis of total petroleum hydrocarbons in air, Anal. Chem., 1997, 69, 3, 402-408, https://doi.org/10.1021/ac960633p . [all data]

Lai and Song, 1995
Lai, W.-C.; Song, C., Temperature-programmed retention indices for g.c. and g.c.-m.s. analysis of coal- and petroleum-derived liquid fuels, Fuel, 1995, 74, 10, 1436-1451, https://doi.org/10.1016/0016-2361(95)00108-H . [all data]

Olson, Sinkevitch, et al., 1992
Olson, K.L.; Sinkevitch, R.M.; Sloane, T.M., Speciation and Quantitation of Hydrocarbons in Gasoline Engine Exhaust, J. Chromatogr. Sci., 1992, 30, 12, 500-508, https://doi.org/10.1093/chromsci/30.12.500 . [all data]

White, Douglas, et al., 1992
White, C.M.; Douglas, L.J.; Hackett, J.P.; Anderson, R.R., Characterization of synthetic gasoline from the chloromethane-zeolite reaction, Energy Fuels, 1992, 6, 1, 76-82, https://doi.org/10.1021/ef00031a012 . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Morinaga, Hara, et al., 1990
Morinaga, M.; Hara, K.; Kageura, M.; Heida, Y.; Takamoto, M.; Kashimura, S., A simple, rapid and simultaneous analysis of complex volatile hydrocarbon mixtures in blood using gas chromatography/mass spectrometry with a wide-bore capillary column, Z. Rechtsmed., 1990, 103, 8, 567-572, https://doi.org/10.1007/BF01261420 . [all data]

Bangjie, Xijian, et al., 1987
Bangjie, C.; Xijian, G.; Shaoyi, P., Calculation of retention indices in temperature-programmed gas chromatography, Chromatographia, 1987, 23, 12, 888-892, https://doi.org/10.1007/BF02261466 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References