2-Pentene, 3-methyl-, (E)-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxaneMethyl SiliconeMethyl SiliconeOV-1OV-1
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Program not specifiednot specifiednot specifiednot specifiednot specified
I 613.618.618.620.620.
ReferenceJunkes, Castanho, et al., 2003Zenkevich and Marinichev, 2001Zenkevich, 2000Zhu and He, 1999Zhu and He, 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryPackedPacked
Active phase SE-54SE-54Methyl SiliconeSE-30Squalane
Column length (m)   115.6.13.0
Carrier gas    N2N2
Substrate    Chromosorb WEmbacel
Column diameter (mm)   0.20  
Phase thickness (μm)   0.30  
Program not specifiednot specifiednot specified50C910min) => 20C/min => 90(6min) => 10C/min => 150C(hold)25C(5min) => 2C/min => 35 => 4C/min => 95C(hold)
I 623.624.613.627.619.
ReferenceZhu and He, 1999Zhu and He, 1999Meng and Liu, 1991Robinson and Odell, 1971Robinson and Odell, 1971
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Junkes, Castanho, et al., 2003
Junkes, B.S.; Castanho, R.D.M.; Amboni, C.; Yunes, R.A.; Heinzen, V.E.F., Semiempirical Topological Index: A Novel Molecular Descriptor for Quantitative Structure-Retention Relationship Studies, Internet Electronic Journal of Molecular Design, 2003, 2, 1, 33-49. [all data]

Zenkevich and Marinichev, 2001
Zenkevich, I.G.; Marinichev, A.N., Comparison of Topological and Dynamics Molecular Characteristics for Precalculation of Chromatographic Retention Parameters of Organic Compounds (in Russian), Zh. Struct. Khim., 2001, 42, 5, 893-902. [all data]

Zenkevich, 2000
Zenkevich, I.G., Mutual Correlation between Gas Chromatographic Retention Indices of Unsaturated and Saturated Hydrocarbons found by Molecular Dynamics, Z. Anal. Chem., 2000, 55, 10, 1091-1097. [all data]

Zhu and He, 1999
Zhu, X.; He, L., Derivation of isothermal retention indices from a retention values under multiple-ramp temperature-programmed conditions, J. Instrum. Anal. (Chinese), 1999, 18, 6, 10-12. [all data]

Meng and Liu, 1991
Meng, W.; Liu, C., Gas chromatographic analysis of alkene imourities in solvent naphtha, China Synth. Rubber Ind., 1991, 14, 2, 109-111. [all data]

Robinson and Odell, 1971
Robinson, P.G.; Odell, A.L., A system of standard retention indices and its uses. The characterisation of stationary phases and the prediction of retention indices, J. Chromatogr., 1971, 57, 1-10, https://doi.org/10.1016/0021-9673(71)80001-8 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References