Anthracene, 1-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Lee's RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-55 % Phenyl methyl siloxaneHP-5SE-54
Column length (m) 30.30. 30.25.
Carrier gas HeliumHe  He
Substrate      
Column diameter (mm) 0.300.3 0.25 
Phase thickness (μm) 0.250.25 0.25 
Tstart (C) 50.50.50.50.130.
Tend (C) 200.200.250.280.260.
Heat rate (K/min) 5.5.2.4.3.
Initial hold (min) 5.5. 2. 
Final hold (min) 15.15. 20.40.
I 315.9316.323.33323.38322.20
ReferenceWang, Hou, et al., 2007Shao, Wang, et al., 2006Skrbic and Onjia, 2006Piao, Chu, et al., 1999Ivanov and Golovko, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase DB-5DB-5SE-52
Column length (m) 30.30.12.
Carrier gas  HeliumHe
Substrate    
Column diameter (mm) 0.320.320.3
Phase thickness (μm)   0.34
Tstart (C) 80.90.50.
Tend (C) 300.250.250.
Heat rate (K/min) 3.54.2.
Initial hold (min) 1.  
Final hold (min) 10.  
I 323.3327.7323.33
ReferencePalmentier, Britten, et al., 1989Viau, Studak, et al., 1984Lee, Vassilaros, et al., 1979
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Lee's RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Wang, Hou, et al., 2007
Wang, G.; Hou, Z.; Sun, Y.; Liu, Y.; Xie, B.; Liu, S., Investigation of pyrolysis behavior of fenoxycarb using PY-GC-MS assisted with chemometric methods, Chem. Anal., 2007, 52, 141-156. [all data]

Shao, Wang, et al., 2006
Shao, X.; Wang, G.; Sun, Y.; Zhang, R.; Xie, K.; Liu, H., Determination and Characterization of the Pyrolysis Products of Isoprocarb by GC-MS, J. Chromatogr. Sci., 2006, 44, 3, 141-147, https://doi.org/10.1093/chromsci/44.3.141 . [all data]

Skrbic and Onjia, 2006
Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 2006, 1108, 2, 279-284, https://doi.org/10.1016/j.chroma.2006.01.080 . [all data]

Piao, Chu, et al., 1999
Piao, M.; Chu, S.; Zheng, M.; Xu, X., Characterization of the combustion products of polyethylene, Chemosphere, 1999, 39, 9, 1497-1512, https://doi.org/10.1016/S0045-6535(99)00054-5 . [all data]

Ivanov and Golovko, 1994
Ivanov, V.I.; Golovko, A.K., Investigation of the composition of petroleum anthracene hydrocarbons, Pet. Chem. USSR (Engl. Transl.), 1994, 34, 6, 504-512. [all data]

Palmentier, Britten, et al., 1989
Palmentier, J.-P.F.; Britten, A.J.; Charbonneau, G.M.; Karasek, F.W., Determination of polycyclic aromatic hydrocarbons in lubricating oil base stocks using high-performance liquid chromatography and gas chromatography-mass spectrometry, J. Chromatogr., 1989, 469, 241-251, https://doi.org/10.1016/S0021-9673(01)96459-3 . [all data]

Viau, Studak, et al., 1984
Viau, A.C.; Studak, S.M.; Karasek, F.W., Comparative analysis of hazardous compounds on flu-ash from municipal waste incineration by gas chromatography / mass spectrometry, Can. J. Chem., 1984, 62, 11, 2140-2145, https://doi.org/10.1139/v84-366 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]


Notes

Go To: Top, Lee's RI, non-polar column, temperature ramp, References