Diallyl sulfide

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SPB-1HP-5 MSSE-30HP-5MSHP-5
Column length (m) 30.30. 30.30.
Carrier gas Helium  HeHe
Substrate      
Column diameter (mm) 0.320.25 0.250.25
Phase thickness (μm) 0.250.25 0.250.25
Program not specified40 0C (3 min) 2 0C/min -> 150 0C 20 0C/min -> 220 0C (5 min)not specified40C (10min) => 3C/min => 120C => 10C/min => 250C (5min)40C (10min) => 3C/min => 120C => 10C/min => 250C (5min)
I 854.831.854.848.848.
ReferenceRao, Nagender, et al., 2007Pyun and Shin, 2006Vinogradov, 2004Ansorena, Gimeno, et al., 2001Ansorena, Astiasarán, et al., 2000
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase CP Sil 5 CBDB-5DB-5DB-5
Column length (m) 50.50.50.50.
Carrier gas HeHeHeHe
Substrate     
Column diameter (mm) 0.320.320.320.32
Phase thickness (μm) 1.20.250.250.25
Program 33C (16.5min) => 2C/min => 160C => 20C/min => 200C (9min)40C (10min) => 3C/min => 95C => 10C/min => 270C (10min)40C (10min) => 3C/min => 95C => 10C/min => 270C (10min)40C (10min) => 3C/min => 95C => 10C/min => 270C (10min)
I 848.867.865.863.
ReferenceGijs, Piraprez, et al., 2000Mateo and Zumalacárregui, 1996Mateo and Zumalacárregui, 1996Mateo and Zumalacárregui, 1996
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Rao, Nagender, et al., 2007
Rao, P.P.; Nagender, A.; Rao, L.J.; Rao, D.G., Studies on the effects of microwave drying and cabinet tray drying on the chemical composition of volatile oils of garlic powders, Eur. Food Res. Technol., 2007, 224, 6, 791-795, https://doi.org/10.1007/s00217-006-0364-3 . [all data]

Pyun and Shin, 2006
Pyun, M.-S.; Shin, S., Antifungal effects of the volatile oils from Allium plants against Trichophyton species and synergism of the oils with ketoconazole, Phytomedicine, 2006, 13, 6, 394-400, https://doi.org/10.1016/j.phymed.2005.03.011 . [all data]

Vinogradov, 2004
Vinogradov, B.A., Production, composition, properties and application of essential oils, 2004, retrieved from http://viness.narod.ru. [all data]

Ansorena, Gimeno, et al., 2001
Ansorena, D.; Gimeno, O.; Astiasarán, I.; Bello, J., Analysis of volatile compounds by GC-MS of a dry fermented sausage: chorizo de Pamplona, Food Res. Int., 2001, 34, 1, 67-75, https://doi.org/10.1016/S0963-9969(00)00133-2 . [all data]

Ansorena, Astiasarán, et al., 2000
Ansorena, D.; Astiasarán, I.; Bello, J., Influence of the simultaneous addition of the protease flavourzyme and the lipase novozyme 677BG on dry fermented sausage compounds extracted by SDE and analyzed by GC-MS, J. Agric. Food Chem., 2000, 48, 6, 2395-2400, https://doi.org/10.1021/jf990931y . [all data]

Gijs, Piraprez, et al., 2000
Gijs, L.; Piraprez, G.; Perpète, P.; Spinnler, E.; Collin, S., Retention of sulfur flavours by food matrix and determination of sensorial data independent of the medium composition, Food Chem., 2000, 69, 3, 319-330, https://doi.org/10.1016/S0956-7135(99)00111-5 . [all data]

Mateo and Zumalacárregui, 1996
Mateo, J.; Zumalacárregui, J.M., Volatile compounds in chorizo and their changes during ripening, Meat Sci., 1996, 44, 4, 255-273, https://doi.org/10.1016/S0309-1740(96)00028-9 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References