2-Pentanol, 2-methyl-
- Formula: C6H14O
- Molecular weight: 102.1748
- IUPAC Standard InChIKey: WFRBDWRZVBPBDO-UHFFFAOYSA-N
- CAS Registry Number: 590-36-3
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: 2-Hydroxy-2-methylpentane; 2-Methyl-2-pentanol; 2-Methylpentan-2-ol; UN 2560; 1,1-Dimethylbutanol; 2-Methyl-2-hydroxypentane; Methyl-2 pentanol-2
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal boiling point
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
Tboil (K) | Reference | Comment |
---|---|---|
394.2 | Weast and Grasselli, 1989 | BS |
394.2 | Majer and Svoboda, 1985 | |
393.65 | Walling and Padwa, 1963 | Uncertainty assigned by TRC = 2. K; ~; TRC |
395. | Saunders, 1956 | Uncertainty assigned by TRC = 2. K; TRC |
394.65 | Pansevich-Kolyada and Prilezhaev, 1951 | Uncertainty assigned by TRC = 2. K; TRC |
394.65 | Pichler, Ziesecke, et al., 1950 | Uncertainty assigned by TRC = 1. K; TRC |
395.15 | Addison, 1945 | Uncertainty assigned by TRC = 2. K; TRC |
395.95 | Wibaut, Hoog, et al., 1939 | Uncertainty assigned by TRC = 1. K; TRC |
395.65 | Ginnings and Webb, 1938 | Uncertainty assigned by TRC = 1. K; TRC |
393.15 | Sutter, 1938 | Uncertainty assigned by TRC = 2. K; TRC |
394.65 | Cottle and Powell, 1936 | Uncertainty assigned by TRC = 2. K; TRC |
394.24 | Hovorka, Lankelma, et al., 1933 | Uncertainty assigned by TRC = 0.2 K; TRC |
396.65 | Van Risseghem, 1933 | Uncertainty assigned by TRC = 4. K; TRC |
392.65 | Krollpfeiffer and Seebaum, 1928 | Uncertainty assigned by TRC = 4. K; TRC |
396.15 | Read and Fletcher, 1925 | Uncertainty assigned by TRC = 2. K; TRC |
395.5 | Willcox and Brunel, 1916 | Uncertainty assigned by TRC = 1. K; TRC |
395.45 | Henry, 1907 | Uncertainty assigned by TRC = 2. K; TRC |
395.15 | Henry, 1906 | Uncertainty assigned by TRC = 1. K; TRC |
397.15 | Masson, 1901 | Uncertainty assigned by TRC = 1. K; TRC |
References
Go To: Top, Normal boiling point, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Weast and Grasselli, 1989
CRC Handbook of Data on Organic Compounds, 2nd Editon, Weast,R.C and Grasselli, J.G., ed(s)., CRC Press, Inc., Boca Raton, FL, 1989, 1. [all data]
Majer and Svoboda, 1985
Majer, V.; Svoboda, V.,
Enthalpies of Vaporization of Organic Compounds: A Critical Review and Data Compilation, Blackwell Scientific Publications, Oxford, 1985, 300. [all data]
Walling and Padwa, 1963
Walling, C.; Padwa, A.,
Positive Halogen Compounds VII. Intramolecular Chlorinations with Long Chain Hypochlorites,
J. Am. Chem. Soc., 1963, 85, 1597. [all data]
Saunders, 1956
Saunders, W.H.,
J. Am. Chem. Soc., 1956, 78, 6127. [all data]
Pansevich-Kolyada and Prilezhaev, 1951
Pansevich-Kolyada, V.I.; Prilezhaev, N.A.,
Zh. Obshch. Khim., 1951, 21, 571. [all data]
Pichler, Ziesecke, et al., 1950
Pichler, H.; Ziesecke, K.H.; Traeger, B.,
The Oxygen-containing Compounds, Especially Alcohols, Formed in Isosynthesis,
Brennst.-Chem., 1950, 31, 361. [all data]
Addison, 1945
Addison, C.C.,
26. The Properties of Freshly Formed Surfaces. IV. The Influence of Chain Length and Structure on the Static and the Dynamic Surface Tensions of Aqueous Alcoholic Solutions,
J. Chem. Soc., 1945, 1945, 98-106. [all data]
Wibaut, Hoog, et al., 1939
Wibaut, J.P.; Hoog, H.; Langedijk, S.L.; Overhoff, J.; Smittenberg, J.; Benninga, N.; Bouman, G.P.; van Dijk, H.; Gaade, W.; Geldof, H.; Hackmann, J.Th.; Jonker, E.W.; Paap, T.; Zuiderweg, F.J.,
Study on the Preparation and the Physical Constants of A Number of Alkanes and Cycloalkanes,
Recl. Trav. Chim. Pays-Bas, 1939, 58, 329. [all data]
Ginnings and Webb, 1938
Ginnings, P.M.; Webb, R.,
Aquesous Solubilities of Some Isomeric Hexanols,
J. Am. Chem. Soc., 1938, 60, 1388-1389. [all data]
Sutter, 1938
Sutter, P.,
Helv. Chim. Acta, 1938, 21, 1266. [all data]
Cottle and Powell, 1936
Cottle, D.L.; Powell, L.S.,
The Reaction of 2,3-Epoxybutane with Grignard Reagent,
J. Am. Chem. Soc., 1936, 58, 2267. [all data]
Hovorka, Lankelma, et al., 1933
Hovorka, F.; Lankelma, H.P.; Naujoks, C.K.,
Thermodynamic Properties of 2-Methyl-2-pentanol,
J. Am. Chem. Soc., 1933, 55, 4820. [all data]
Van Risseghem, 1933
Van Risseghem, H.,
Bull. Soc. Chim. Belg., 1933, 42, 219. [all data]
Krollpfeiffer and Seebaum, 1928
Krollpfeiffer, F.; Seebaum, H.,
J. Prakt. Chem., 1928, 119, 131. [all data]
Read and Fletcher, 1925
Read; Fletcher,
Trans. Am. Electrochem. Soc., 1925, 47, 93. [all data]
Willcox and Brunel, 1916
Willcox, M.; Brunel, R.F.,
J. Am. Chem. Soc., 1916, 38, 1821. [all data]
Henry, 1907
Henry, L.,
Recl. Trav. Chim. Pays-Bas, 1907, 26, 84. [all data]
Henry, 1906
Henry, L.,
C. R. Hebd. Seances Acad. Sci., 1906, 143, 102. [all data]
Masson, 1901
Masson, H.,
Syntheses of tertiary alcohols of the fatty acids,
C. R. Hebd. Seances Acad. Sci., 1901, 132, 483-5. [all data]
Notes
Go To: Top, Normal boiling point, References
- Symbols used in this document:
Tboil Boiling point - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.