Hexane, 3-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5Petrocol DHSPB-1SPB-1DB-5
Column length (m) 50.50.30.30.30.
Carrier gas HeHe  He
Substrate      
Column diameter (mm) 0.320.250.250.250.25
Phase thickness (μm) 1.050.50.250.251.
Tstart (C) 35.35.40.40.50.
Tend (C) 220.200.250.250.200.
Heat rate (K/min) 8.3.10.10.2.5
Initial hold (min) 15.10.2.2. 
Final hold (min) 5.10.2.2. 
I 671.673.9666.92667.66672.7
ReferenceInsausti, Goñi, et al., 2005Censullo, Jones, et al., 2003LECO Corporation, 2003LECO Corporation, 2003Xu, van Stee, et al., 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101Petrocol DHPetrocol DHUltra-1Petrocol DH
Column length (m) 80.100.100. 100.
Carrier gas N2HeHe He
Substrate      
Column diameter (mm) 0.220.250.25 0.25
Phase thickness (μm)  0.50.5 0.5
Tstart (C) 30.30.30.-40.30.
Tend (C) 130.220.220.230.220.
Heat rate (K/min) 1.1.1.4.1.
Initial hold (min)      
Final hold (min)      
I 672.2670.16670.26676.670.56
ReferenceYin, Liu, et al., 2001Subramaniam, Bochniak, et al., 1994Subramaniam, Bochniak, et al., 1994Olson, Sinkevitch, et al., 1992White, Douglas, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Petrocol DHPetrocol DHHP-1HP-1HP-1
Column length (m) 100.100.25.25.25.
Carrier gas HeHeN2N2N2
Substrate      
Column diameter (mm) 0.250.250.20.20.2
Phase thickness (μm) 0.50.5   
Tstart (C) 30.30.30.30.30.
Tend (C) 220.220.   
Heat rate (K/min) 1.1.10.2.5.
Initial hold (min)     5.
Final hold (min)      
I 670.6671.676.9676.5675.8
ReferenceWhite, Douglas, et al., 1992White, Hackett, et al., 1992Bangjie, Xijian, et al., 1987Bangjie, Xijian, et al., 1987Bangjie, Xijian, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-101
Column length (m) 108.
Carrier gas  
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm) 0.2
Tstart (C) 35.
Tend (C) 200.
Heat rate (K/min) 1.
Initial hold (min)  
Final hold (min)  
I 669.
ReferenceHayes and Pitzer, 1981
Comment MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Insausti, Goñi, et al., 2005
Insausti, K.; Goñi, V.; Petri, E.; Gorraiz, C.; Beriain, M.J., Effect of weight at slaughter on the volatile compounds of cooked beef from Spanish cattle breeds, Meat Sci., 2005, 70, 1, 83-90, https://doi.org/10.1016/j.meatsci.2004.12.003 . [all data]

Censullo, Jones, et al., 2003
Censullo, A.C.; Jones, D.R.; Wills, M.T., Speciation of the volatile organic compounds (VOCs) in solventborne aerosol coatings by solid phase microextraction-gas chromatography, J. Coat. Technol., 2003, 75, 936, 47-53, https://doi.org/10.1007/BF02697922 . [all data]

LECO Corporation, 2003
LECO Corporation, Determination of hydrocarbon components in petroleum naphthas, 2003, retrieved from http://www.leco.org/customersupport/apps/separationscience/-190.pdf. [all data]

Xu, van Stee, et al., 2003
Xu, X.; van Stee, L.L.P.; Williams, J.; Beens, J.; Adahchour, M.; Vreuls, R.J.J.; Brinkman, U.A.Th.; Lelieveld, J., Comprehensive two-dimensional gas chromatography (GC×GC) measurements of volatile organic compounds in the atmosphere, Atmos. Chem. Phys., 2003, 3, 3, 665-682, https://doi.org/10.5194/acp-3-665-2003 . [all data]

Yin, Liu, et al., 2001
Yin, C.; Liu, W.; Li, Z.; Pan, Z.; Lin, T.; Zhang, M., Chemometrics to chemical modeling: structural coding in hydrocarbons and retention indices of gas chromatography, J. Sep. Sci., 2001, 24, 3, 213-220, https://doi.org/10.1002/1615-9314(20010301)24:3<213::AID-JSSC213>3.0.CO;2-4 . [all data]

Subramaniam, Bochniak, et al., 1994
Subramaniam, B.; Bochniak, D.; Snavely, K., Fischer-Tropsch synthesis in supercritical reaction media, Lawrence Department of Chemical and Petroleum Engineering (DOE/PC/92532--T7), United States Department of Energy, Pittsburgh, PA, 1994, 8, retrieved from http://www.NTIS.gov. [all data]

Olson, Sinkevitch, et al., 1992
Olson, K.L.; Sinkevitch, R.M.; Sloane, T.M., Speciation and Quantitation of Hydrocarbons in Gasoline Engine Exhaust, J. Chromatogr. Sci., 1992, 30, 12, 500-508, https://doi.org/10.1093/chromsci/30.12.500 . [all data]

White, Douglas, et al., 1992
White, C.M.; Douglas, L.J.; Hackett, J.P.; Anderson, R.R., Characterization of synthetic gasoline from the chloromethane-zeolite reaction, Energy Fuels, 1992, 6, 1, 76-82, https://doi.org/10.1021/ef00031a012 . [all data]

White, Hackett, et al., 1992
White, C.M.; Hackett, J.; Anderson, R.R.; Kail, S.; Spock, P.S., Linear temperature programmed retention indices of gasoline range hydrocarbons and chlorinated hydrocarbons on cross-linked polydimethylsiloxane, J. Hi. Res. Chromatogr., 1992, 15, 2, 105-120, https://doi.org/10.1002/jhrc.1240150211 . [all data]

Bangjie, Xijian, et al., 1987
Bangjie, C.; Xijian, G.; Shaoyi, P., Calculation of retention indices in temperature-programmed gas chromatography, Chromatographia, 1987, 23, 12, 888-892, https://doi.org/10.1007/BF02261466 . [all data]

Hayes and Pitzer, 1981
Hayes, P.C., Jr.; Pitzer, E.W., Kovats indices as a tool in characterizing hydrocarbon fuels in temperature programmed glass capillary gas chromatography. Part 1. Qualitative identification, Inhouse rpt. for Air Force Wright Aeronautical Labs., Air Force Wright Aeronautical Labs., Wright-Patterson AFB, Ohio, 1981, 75. [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References