Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedCapillaryCapillaryPacked
Active phase SE-30DB-5OV-1SE-30
Column length (m) 2.15. 2.
Carrier gas NitrogenHe  
Substrate Chromosorb G AW DMCS (80-100 mesh)  Gas Chrom P
Column diameter (mm)  0.25  
Phase thickness (μm)  0.2  
Tstart (C) 100.185.200.120.
Tend (C) 300.270.280.200.
Heat rate (K/min)  10.16.2.5
Initial hold (min)     
Final hold (min)     
I 1873.1844.1873.1865.
ReferenceMHA, 9999Phillips, Logan, et al., 1990Schutz and Wollrab A., 1988Marozzi, Gambaro, et al., 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

MHA, 9999
MHA, Directorate of ForensicScience., Forensic Toxicology, 9999. [all data]

Phillips, Logan, et al., 1990
Phillips, A.M.; Logan, B.K.; Stafford, D.T., Further applications for capillary gas chromatography in routine quantitative toxicological analyses, J. Hi. Res. Chromatogr., 1990, 13, 11, 754-758, https://doi.org/10.1002/jhrc.1240131106 . [all data]

Schutz and Wollrab A., 1988
Schutz, H.; Wollrab A., The significance of the retention index in toxicologic analysis II, Pharmazie in unzerer Zeit, 1988, 17, 4, 97-101. [all data]

Marozzi, Gambaro, et al., 1982
Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 1982, 6, 4, 185-192, https://doi.org/10.1093/jat/6.4.185 . [all data]