Naphthalene, 2,6-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Lee's RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5MS5 % Phenyl methyl siloxane5 % Phenyl methyl siloxaneDB-5MSPTE-5
Column length (m) 30.  30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.25  0.250.25
Phase thickness (μm) 0.25  0.50.25
Tstart (C) 50.50.80.40.60.
Tend (C) 300.250.300.310.300.
Heat rate (K/min) 6.2.8.10.8.
Initial hold (min) 2. 2.1.1.5
Final hold (min) 16. 10. 12.5
I 240.68237.58239.70240.42240.56
ReferenceSun, Zhou, et al., 2008Skrbic and Onjia, 2006Skrbic and Onjia, 2006Chen, Keeran, et al., 2002Wang, Jia, et al., 2000
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-52DB-5DB-5CP Sil 8 CBSE-54
Column length (m) 30.25.30.50.20.
Carrier gas  HeHeHeHe
Substrate      
Column diameter (mm) 0.300.30.320.250.22
Phase thickness (μm)   0.250.250.20
Tstart (C) 40.60.50.80.50.
Tend (C) 250.270.300.300.300.
Heat rate (K/min) 4.5.6.4.4.
Initial hold (min)  2.2.  
Final hold (min)      
I 239.97240.04241.00240.5237.23
ReferenceWang, Peng, et al., 1997Williams and Horne, 1995Wang, Fingas, et al., 1994Bundt, Herbel, et al., 1991Guillén, Blanco, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5SE-52SE-52
Column length (m) 30.30.20.12.
Carrier gas HeHeliumH2He
Substrate     
Column diameter (mm) 0.260.320.300.3
Phase thickness (μm) 0.25 0.250.34
Tstart (C) 50.90.40.50.
Tend (C) 300.250.265.250.
Heat rate (K/min) 6.4.4.2.
Initial hold (min) 4. 2. 
Final hold (min) 20.   
I 240.89233.9240.28237.58
ReferenceRostad and Pereira, 1986Viau, Studak, et al., 1984Vassilaros, Kong, et al., 1982Lee, Vassilaros, et al., 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Lee's RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Sun, Zhou, et al., 2008
Sun, P.; Zhou, Q.; Li, G.; Wang, X.; Zhao, Y.; Cao, L., fingerprint analysis of polycyclic aromatic hydrocarbons in crude oil by internal standard method, J. Instrumental Anal., 2008, 27, 4, 344-348. [all data]

Skrbic and Onjia, 2006
Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 2006, 1108, 2, 279-284, https://doi.org/10.1016/j.chroma.2006.01.080 . [all data]

Chen, Keeran, et al., 2002
Chen, P.H.; Keeran, W.S.; Van Ausdale, W.A.; Schindler, D.R.; Roberts, D.W., Application of Lee retention indices to the confirmation of tentatively identified compounds from GC/MS analysis of environmental samples, Technical paper, Analytical Services Division, Environmental ScienceEngineering, Inc, PO Box 1703, Gainesville, FL 32602, 2002, 11. [all data]

Wang, Jia, et al., 2000
Wang, J.; Jia, C.R.; Wong, C.K.; Wong, P.K., Characterization of polycyclic aromatic hydrocarbons created in lubricating oils, Water Air Soil Poll., 2000, 120, 3/4, 381-396, https://doi.org/10.1023/A:1005251618062 . [all data]

Wang, Peng, et al., 1997
Wang, Y.; Peng, P.; Cui, S.; Zhang, Y., Identification of PAH in the Suzhou River bed sediments by GC/MS and PAH retention index system, J. Nanjing Norm. Univ. (Nat. Sci.), 1997, 20, 2, 47-68. [all data]

Williams and Horne, 1995
Williams, P.T.; Horne, P.A., Analysis of aromatic hydrocarbons in pyrolytic oil derived from biomass, J. Anal. Appl. Pyrolysis, 1995, 31, 15-37, https://doi.org/10.1016/0165-2370(94)00814-H . [all data]

Wang, Fingas, et al., 1994
Wang, Z.; Fingas, M.; Li, K., Fractionation of a light crude oil and identification and quantitation of aliphatic, aromatic, and biomarker comopunds by GC-FID and GC-MS, Part II, J. Chromatogr. Sci., 1994, 32, 9, 367-382, https://doi.org/10.1093/chromsci/32.9.367 . [all data]

Bundt, Herbel, et al., 1991
Bundt, J.; Herbel, W.; Steinhart, H.; Franke, S.; Francke, W., Structure-type separation of diesel fuels by solid phase extraction and identification of the two- and three-ring aromatics by capillary GC-mass spectrometry, J. Hi. Res. Chromatogr., 1991, 14, 2, 91-98, https://doi.org/10.1002/jhrc.1240140205 . [all data]

Guillén, Blanco, et al., 1989
Guillén, M.D.; Blanco, J.; Bermejo, J.; Blanco, C.G., Temperature programmed retention indices of some PAHs on Capillary columns coated with OV-1701 and SE-54, J. Hi. Res. Chromatogr., 1989, 12, 8, 552-554, https://doi.org/10.1002/jhrc.1240120816 . [all data]

Rostad and Pereira, 1986
Rostad, C.E.; Pereira, W.E., Kovats and Lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 6, 328-334, https://doi.org/10.1002/jhrc.1240090603 . [all data]

Viau, Studak, et al., 1984
Viau, A.C.; Studak, S.M.; Karasek, F.W., Comparative analysis of hazardous compounds on flu-ash from municipal waste incineration by gas chromatography / mass spectrometry, Can. J. Chem., 1984, 62, 11, 2140-2145, https://doi.org/10.1139/v84-366 . [all data]

Vassilaros, Kong, et al., 1982
Vassilaros, D.L.; Kong, R.C.; Later, D.W.; Lee, M.L., Linear retention index system for polycyclic aromatic compounds. Critical evaluation and additional indices, J. Chromatogr., 1982, 252, 1-20, https://doi.org/10.1016/S0021-9673(01)88394-1 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]


Notes

Go To: Top, Lee's RI, non-polar column, temperature ramp, References