Caffeine

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryPackedPacked
Active phase DB-1SPB-1CBP-1Methyl SiliconeMethyl Silicone
Column length (m) 30.30.12.  
Carrier gas  HeN2  
Substrate      
Column diameter (mm) 0.20.750.53  
Phase thickness (μm) 0.251.0   
Tstart (C) 50.160.120.120.120.
Tend (C) 300.280.250.290.290.
Heat rate (K/min) 5.10.6.7.7.
Initial hold (min) 2.  4.4.
Final hold (min) 5.12. 10.10.
I 1760.1811.1769.1830.1835.
ReferenceJohnson, Urso, et al., 1997Christ, Noomano, et al., 1988Oyama, Sano, et al., 1987Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 120.120.120.120.120.
Tend (C) 290.290.290.290.290.
Heat rate (K/min) 7.7.7.7.7.
Initial hold (min) 4.4.4.4.4.
Final hold (min) 10.10.10.10.10.
I 1796.1800.1805.1810.1810.
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 120.120.120.120.120.
Tend (C) 290.290.290.290.290.
Heat rate (K/min) 7.7.7.7.7.
Initial hold (min) 4.4.4.4.4.
Final hold (min) 10.10.10.10.10.
I 1810.1810.1813.1813.1815.
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 120.120.120.120.120.
Tend (C) 290.290.290.290.290.
Heat rate (K/min) 7.7.7.7.7.
Initial hold (min) 4.4.4.4.4.
Final hold (min) 10.10.10.10.10.
I 1815.1807.1810.1810.1813.
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 120.120.120.120.120.
Tend (C) 290.290.290.290.290.
Heat rate (K/min) 7.7.7.7.7.
Initial hold (min) 4.4.4.4.4.
Final hold (min) 10.10.10.10.10.
I 1813.1815.1815.1818.1830.
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 120.120.120.120.120.
Tend (C) 290.290.290.290.290.
Heat rate (K/min) 7.7.7.7.7.
Initial hold (min) 4.4.4.4.4.
Final hold (min) 10.10.10.10.10.
I 1798.1800.1800.1800.1800.
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase Methyl SiliconeMethyl SiliconeMethyl SiliconeMethyl SiliconeMethyl Silicone
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Tstart (C) 120.120.120.120.120.
Tend (C) 290.290.290.290.290.
Heat rate (K/min) 7.7.7.7.7.
Initial hold (min) 4.4.4.4.4.
Final hold (min) 10.10.10.10.10.
I 1800.1802.1805.1805.1805.
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedCapillaryCapillaryCapillary
Active phase Methyl SiliconeMethyl SiliconeDB-1Methyl Silicone5 % Phenyl methyl siloxane
Column length (m)   15.12.12.
Carrier gas   HeHeHe
Substrate      
Column diameter (mm)   0.320.20.2
Phase thickness (μm)   0.250.330.33
Tstart (C) 120.120.120.50.50.
Tend (C) 290.290.280.300.300.
Heat rate (K/min) 7.7.8.20.20.
Initial hold (min) 4.4. 1.1.
Final hold (min) 10.10.5.3.3.
I 1810.1850.1768.1764.01848.0
ReferenceBogusz, Wijsbeek, et al., 1985Bogusz, Wijsbeek, et al., 1985Perrigo, Peel, et al., 1985Newton and Foery, 1984Newton and Foery, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase DB-1DB-1DB-1DB-1SE-30
Column length (m) 15.15.15.15.1.8
Carrier gas HeHeHeHeN2
Substrate     Chromosorb W
Column diameter (mm) 0.250.250.250.25 
Phase thickness (μm) 0.250.250.250.25 
Tstart (C) 120.120.120.120.130.
Tend (C) 280.280.280.280.290.
Heat rate (K/min) 8.12.15.5.8.
Initial hold (min)     2.
Final hold (min) 5.5.5.5.8.
I 1768.1775.1778.1761.1800.
ReferencePerrigo, Ballantyne, et al., 1984Perrigo, Ballantyne, et al., 1984Perrigo, Ballantyne, et al., 1984Perrigo, Ballantyne, et al., 1984Perrigo and Peel, 1981
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Johnson, Urso, et al., 1997
Johnson, C.I.; Urso, A.; Geleta, L., Broad spectrum analysis of municipal and industrial effluents discharged into the Peace, Athabasca and Slave river basins: characterization of effluent samples, 1994 - Volume 1 of 2, Northern River Basins Study Project Report No. 121, Norther River Basins Study, Edmonton, Alberta, 1997, 27. [all data]

Christ, Noomano, et al., 1988
Christ, D.W.; Noomano, P.; Rosas, M.; Rhone, D., Retention indices by wide-bore capillary gas chromatography with nitrogen-phosphorus detection, J. Anal. Toxicol., 1988, 12, 2, 84-88, https://doi.org/10.1093/jat/12.2.84 . [all data]

Oyama, Sano, et al., 1987
Oyama, N.; Sano, T.; Syoyama, M.; Maeda, K., Studies on systematic analysis of poisonous compounds in forensic chemistry. II. Application of capillary column gas chromatography to substance identification by means of retention indices, Eisei Kagaku, 1987, 33, 5, 342-348, https://doi.org/10.1248/jhs1956.33.342 . [all data]

Bogusz, Wijsbeek, et al., 1985
Bogusz, M.; Wijsbeek, J.; Franke, J.P.; de Zeeuw, R.A.; Gierz, J., Impact of biological matrix, drug concentration, and method of isolation on detectability and variability of retention index values in gas chromatography, J. Anal. Toxicol., 1985, 9, 2, 49-54, https://doi.org/10.1093/jat/9.2.49 . [all data]

Perrigo, Peel, et al., 1985
Perrigo, B.J.; Peel, H.W.; Ballantyne, D.J., Use of Dual-Column Fused-Silica Capillary Gas Chromatography in Combination with Detector Response Factors for Analytical Toxicology., J. Chromatogr., 1985, 341, 81-88, https://doi.org/10.1016/S0378-4347(00)84011-6 . [all data]

Newton and Foery, 1984
Newton, B.; Foery, R.F., Retention indices and dual capillary gas chromatography for rapid identification of sedative hypnotic drugs in emergency toxicology, J. Anal. Toxicol., 1984, 8, 3, 129-134, https://doi.org/10.1093/jat/8.3.129 . [all data]

Perrigo, Ballantyne, et al., 1984
Perrigo, B.J.; Ballantyne, D.J.; Peel, H.W., Condierations in developing a data base for drugs on a DBI capillary column, J. Can. Soc. Forensic Sci., 1984, 17, 2, 41-49, https://doi.org/10.1080/00085030.1984.10757360 . [all data]

Perrigo and Peel, 1981
Perrigo, B.J.; Peel, H.W., The use of retention indices and temperature-programmed gas chromatography in analytical toxicology, J. Chromatogr. Sci., 1981, 19, 5, 219-226, https://doi.org/10.1093/chromsci/19.5.219 . [all data]


Notes