Cholesterol

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedPackedPacked
Active phase SE-30SE-30SE-30E-301E-301
Column length (m) 1.21.21.21.21.2
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 230.240.250.220.230.
I 3020.3034.3051.3043.3023.
ReferenceKeiser, Retunskii, et al., 1990Keiser, Retunskii, et al., 1990Keiser, Retunskii, et al., 1990Keiser, Retunskii, et al., 1990Keiser, Retunskii, et al., 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedCapillaryCapillaryPacked
Active phase E-301E-301CP Sil 5 CBBP-1SE-30
Column length (m) 1.21.250.25.1.2
Carrier gas N2N2H2N2N2
Substrate      
Column diameter (mm)   0.220.22 
Phase thickness (μm)   0.120.25 
Temperature (C) 230.240.270.275.230.
I 3053.3044.3068.3093.3020.
ReferenceKeiser, Retunskii, et al., 1990Keiser, Retunskii, et al., 1990van Gelder, Jonker, et al., 1988Japp, Gill, et al., 1987Keiser, Yazlovetsky, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPacked
Active phase SE-30SE-30OV-1SE-30
Column length (m) 1.21.21.1.
Carrier gas N2N2  
Substrate   Gas Chrom QGas Chrom P AW DMCS
Column diameter (mm)     
Phase thickness (μm)     
Temperature (C) 240.250.260.225.
I 3034.3051.3071.3005.
ReferenceKeiser, Yazlovetsky, et al., 1986Keiser, Yazlovetsky, et al., 1986Quilliam and Westmore, 1978Knights, 1966
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Keiser, Retunskii, et al., 1990
Keiser, L.S.; Retunskii, V.N.; Yazlovetskii, I.G., Gas chromatographic identification of sterols in insects. Estimation of retention data reproducibility, Zh. Anal. Khim., 1990, 45, 1767-1773. [all data]

van Gelder, Jonker, et al., 1988
van Gelder, W.M.J.; Jonker, H.H.; Huizing, H.J.; Scheffer, J.J.C., Capillary gas chromatography of steroidal alkaloids from Solanaceae. Retention indices and simultaneous flame ionization/nitrogen-specific detection, J. Chromatogr., 1988, 442, 133-145, https://doi.org/10.1016/S0021-9673(00)94463-7 . [all data]

Japp, Gill, et al., 1987
Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 1987, 32, 6, 1574-1586. [all data]

Keiser, Yazlovetsky, et al., 1986
Keiser, L.S.; Yazlovetsky, I.G.; Retunsky, V.N., Gas-chromatographic indentification of sterols in insects with the use of two-dimentional three-phase diagrams plotted on the basis of logarithmic retention indices, J. Anal. Chem. USSR (Engl. Transl.), 1986, 41, 9, 1166-1172. [all data]

Quilliam and Westmore, 1978
Quilliam, M.A.; Westmore, J.B., Sterically crowded trialkylsilyl derivatives for chromatography and mass spectrometry of biologically-important compounds, Anal. Chem., 1978, 50, 1, 59-68, https://doi.org/10.1021/ac50023a020 . [all data]

Knights, 1966
Knights, B.A., Application of retention indices to steroid gas chromatography, J. Gas Chromatogr., 1966, 4, 9, 329-331, https://doi.org/10.1093/chromsci/4.9.329 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References