Barbital

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryPackedPackedPacked
Active phase BP-1BP-1SE-30OV-1OV-101
Column length (m) 25.25.  2.
Carrier gas N2N2  N2
Substrate     Chromosorb G AW DMCS (80-100 mesh)
Column diameter (mm) 0.220.53   
Phase thickness (μm) 0.251.   
Temperature (C) 130.130.200.200.200.
I 1461.1478.1482.1480.1480.
ReferenceJapp, Gill, et al., 1987Japp, Gill, et al., 1987Stead, Gill, et al., 1982Berninger and Möller, 1977Möller, 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedPackedPackedPacked
Active phase OV-101OV-101OV-101OV-101OV-101
Column length (m) 2.2.2.2.2.
Carrier gas N2N2N2N2N2
Substrate Chromosorb G AW DMCS (80-100 mesh)Chromosorb G AW DMCS (80-100 mesh)Chromosorb G AW DMCS (80-100 mesh)Chromosorb WChromosorb W
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 200.200.200.150.190.
I 1480.1500.1500.1481.1496.
ReferenceMöller, 1976Möller, 1976Möller, 1976Möller, 1976Möller, 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase OV-101
Column length (m) 2.
Carrier gas N2
Substrate Chromosorb W
Column diameter (mm)  
Phase thickness (μm)  
Temperature (C) 230.
I 1519.
ReferenceMöller, 1976
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Japp, Gill, et al., 1987
Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 1987, 32, 6, 1574-1586. [all data]

Stead, Gill, et al., 1982
Stead, A.H.; Gill, R.; Evans, A.T.; Moffat, A.C., Predictions of gas chromatographic retention characteristics of barbiturates from molecular structure, J. Chromatogr., 1982, 234, 2, 277-283, https://doi.org/10.1016/S0021-9673(00)81866-X . [all data]

Berninger and Möller, 1977
Berninger, H.; Möller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 1977, 37, 4, 295-305, https://doi.org/10.1007/BF00330821 . [all data]

Möller, 1976
Möller, M.R., Comparability of retention indices of polar substances at elevated temperatures, Chromatographia, 1976, 9, 7, 311-314, https://doi.org/10.1007/BF02268832 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References