Carbon Tetrachloride

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedCapillaryCapillaryCapillaryCapillary
Active phase SE-30HP-5BP-1SE-54DB-1
Column length (m) 2.30.50.36.60.
Carrier gas Nitrogen He He
Substrate Chromosorb G AW DMCS (80-100 mesh)    
Column diameter (mm)  0.250.220.250.32
Phase thickness (μm)   0.750.251.2
Tstart (C) 100.50.50.35.30.
Tend (C) 300.200.200.240.240.
Heat rate (K/min)  3.5.5.3.
Initial hold (min)     10.
Final hold (min)      
I 659.656.663.661.654.
ReferenceMHA, 9999Isidorov and Jdanova, 2002Health Safety Executive, 2000Huang, Liang, et al., 1996Ciccioli, Cecinato, et al., 1992
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase OV-101DB-1
Column length (m) 50.50.
Carrier gas He 
Substrate   
Column diameter (mm) 0.320.32
Phase thickness (μm) 0.5 
Tstart (C) 50.0.
Tend (C) 250.250.
Heat rate (K/min) 4.3.
Initial hold (min)   
Final hold (min)   
I 645.645.
ReferenceMisharina, Golovnya, et al., 1991Habu, Flath, et al., 1985
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

MHA, 9999
MHA, Directorate of ForensicScience., Forensic Toxicology, 9999. [all data]

Isidorov and Jdanova, 2002
Isidorov, V.; Jdanova, M., Volatile organic compounds from leaves litter, Chemosphere, 2002, 48, 9, 975-979, https://doi.org/10.1016/S0045-6535(02)00074-7 . [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Huang, Liang, et al., 1996
Huang, C.; Liang, H.; Han, S., The analysis of organic compounds in waste water by gas extraction/thermal desorption/gas chromatography-mass spectrometry, Chin. J. Chromatogr., 1996, 14, 6, 421-424. [all data]

Ciccioli, Cecinato, et al., 1992
Ciccioli, P.; Cecinato, A.; Brancaleoni, E.; Frattoni, M.; Liberti, A., Use of carbon adsorption traps combined with high resolution gas chromatography - mass spectrometry for the analysis of polar and non-polar C4-C14 hydrocarbons involved in photochemical smog formation, J. Hi. Res. Chromatogr., 1992, 15, 2, 75-84, https://doi.org/10.1002/jhrc.1240150205 . [all data]

Misharina, Golovnya, et al., 1991
Misharina, T.A.; Golovnya, R.V.; Charnomskii, V.V., Volatile components of boiled shrimp funchalia woodwardi and crab geryon maritae, Zh. Anal. Khim., 1991, 46, 1421-1429. [all data]

Habu, Flath, et al., 1985
Habu, T.; Flath, R.A.; Mon, T.R.; Morton, J.F., Volatile components of Rooibos tea (Aspalathus linearis), J. Agric. Food Chem., 1985, 33, 2, 249-254, https://doi.org/10.1021/jf00062a024 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References