Cyclotetrasiloxane, octamethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, NIST Free Links, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
BS - Robert L. Brown and Stephen E. Stein
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos

Quantity Value Units Method Reference Comment
Tboil448. - 449.KN/APCR Inc., 1990BS
Tboil446.2KN/AMyers and Clever, 1969Uncertainty assigned by TRC = 0.6 K; TRC
Quantity Value Units Method Reference Comment
Tfus290.KN/AAlvik and Dale, 1971Uncertainty assigned by TRC = 0.1 K; TRC
Tfus290.65KN/AMarsh, 1968Uncertainty assigned by TRC = 0.2 K; TRC
Tfus287.4KN/AOsthoff, Grubb, et al., 1953Uncertainty assigned by TRC = 0.1 K; TRC
Quantity Value Units Method Reference Comment
Ttriple290.250KN/AMekhtiev and Karasharli, 1981Uncertainty assigned by TRC = 0.02 K; by adiabatic calorimeter; TRC
Ttriple23.760KN/AMekhtiev and Karasharli, 1981Uncertainty assigned by TRC = 0.04 K; by adiabatic calorimeter; TRC
Quantity Value Units Method Reference Comment
Tc585.7KN/AMcLure and Neville, 1982Uncertainty assigned by TRC = 0.3 K; Visual, TE, PG; TRC
Tc586.5KN/AYoung, 1972Uncertainty assigned by TRC = 0.2 K; Visual, TE calib. known Tc of alkanes, PP, sample prep and purification according to K.N.Marsh and R.P.Tomlins, 1970; TRC
Quantity Value Units Method Reference Comment
Pc13.03atmN/AMcLure and Neville, 1982Uncertainty assigned by TRC = 0.20 atm; Visual, TE, PG; TRC
Pc13.2207atmN/AYoung, 1972Uncertainty assigned by TRC = 0.0677 atm; TRC
Quantity Value Units Method Reference Comment
Vc1.005l/molN/AMcLure and Neville, 1982Uncertainty assigned by TRC = 0.001 l/mol; Visual, TE, PG; TRC
Vc0.984l/molN/AYoung, 1972Uncertainty assigned by TRC = 0.003 l/mol; by method of H.von Eck, Z.Phys. 1939,40,13,; TRC
Quantity Value Units Method Reference Comment
ρc0.995mol/lN/AMcLure and Neville, 1982Uncertainty assigned by TRC = 0.00991 mol/l; Visual, TE, PG; TRC
Quantity Value Units Method Reference Comment
Δvap13.6 ± 0.2kcal/molCVoronkov, Klyuchnikov, et al., 1991AC
Δvap13.4kcal/molIOsthoff and Grubb, 1954Based on data from 303. - 428. K.; AC

Enthalpy of vaporization

ΔvapH (kcal/mol) Temperature (K) Method Reference Comment
11.4376.EBFlaningam, 1986Based on data from 361. - 469. K.; AC
10.5378.N/ADitsent, Skorokhodov, et al., 1971Based on data from 334. - 423. K.; AC
11.6373.IOsthoff and Grubb, 1954Based on data from 303. - 428. K.; AC
10.9398.IOsthoff and Grubb, 1954Based on data from 303. - 428. K.; AC

Antoine Equation Parameters

log10(P) = A − (B / (T + C))
    P = vapor pressure (atm)
    T = temperature (K)

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) A B C Reference Comment
303.6 - 428.54.07731469.89-87.516Osthoff and Grubb, 1954Coefficents calculated by NIST from author's data.

Enthalpy of fusion

ΔfusH (kcal/mol) Temperature (K) Reference Comment
5.681290.5Domalski and Hearing, 1996See also Mekhtiev, Karasharli, et al., 1975 and Alvik, Dale, et al., 1971.; AC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


IR Spectrum

Go To: Top, Phase change data, Mass spectrum (electron ionization), Gas Chromatography, NIST Free Links, References, Notes

Data compiled by: Coblentz Society, Inc.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director


Mass spectrum (electron ionization)

Go To: Top, Phase change data, IR Spectrum, Gas Chromatography, NIST Free Links, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin R.W.CRAWFORD UNIV. OF CALIFORNIA, LIVERMORE, CALIFORNIA, USA
NIST MS number 23218

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Phase change data, IR Spectrum, Mass spectrum (electron ionization), NIST Free Links, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryUltra-11004.Richmond and Pombo-Villar, 199825. m/0.32 mm/0.52 μm, He, 15. K/min, 320. C @ 10. min; Tstart: 35. C

Normal alkane RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
CapillaryHP-5994.Jung, Wichmann, et al., 199925. m/0.20 mm/0.33 μm, 50. C @ 3. min, 5. K/min; Tend: 180. C
CapillaryMethyl Silicone1022.Fujimoto, Ohtani, et al., 199025. m/0.25 mm/0.1 μm, He, 5. K/min; Tstart: 40. C; Tend: 350. C

Normal alkane RI, non-polar column, custom temperature program

View large format table.

Column type Active phase I Reference Comment
CapillaryUltra-11010.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11010.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11011.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11013.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11017.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11017.Kazuyoshi, Seiichi, et al., 200030. m/0.25 mm/0.50 μm; Program: 40 0C (5 min) 10 0C/min -> 200 0C 20 0C/min -> 320 0C (13 min)
CapillaryUltra-11000.Richmond and Pombo-Villar, 199825. m/0.32 mm/0.52 μm, He; Program: not specified

References

Go To: Top, Phase change data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, NIST Free Links, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

PCR Inc., 1990
PCR Inc., Research Chemicals Catalog 1990-1991, PCR Inc., Gainesville, FL, 1990, 1. [all data]

Myers and Clever, 1969
Myers, R.S.; Clever, H.L., Surface Tension of Octamethylcyclotetrasiloxane and Hexamethyldisilazane and Their Solutions with Carbon Tetrachloride and n-Hexadecane, J. Chem. Eng. Data, 1969, 14, 161-164. [all data]

Alvik and Dale, 1971
Alvik, T.; Dale, J., On the Lack of Conformational Preferences for Cyclic Dimethylsiloxane Oligomers., Acta Chem. Scand., 1971, 25, 2131, https://doi.org/10.3891/acta.chem.scand.25-2131 . [all data]

Marsh, 1968
Marsh, K.N., Thermodynamics of Octamethylcyclotetrasiloxane mixtures, Trans. Faraday Soc., 1968, 64, 883. [all data]

Osthoff, Grubb, et al., 1953
Osthoff, R.C.; Grubb, W.T.; Burkhard, C.A., Physical Properties of organosilicon compounds. I. Hexamethylcyclotrisiloxane and Octamethylcyclotetrasiloxane, J. Am. Chem. Soc., 1953, 75, 2227-9. [all data]

Mekhtiev and Karasharli, 1981
Mekhtiev, S.A.; Karasharli, K.A., Analysis of the results of thermodynamic studies of a series of organosilicon compounds, Azerb. Khim. Zhur., 1981, (5), 85-88. [all data]

McLure and Neville, 1982
McLure, I.A.; Neville, J.F., The critical temperatures and pressures of hexamethyldisilmethylene, octamethylcyclotetrasiloxane, and decamethylcyclpentasiloxane, J. Chem. Thermodyn., 1982, 14, 385-8. [all data]

Young, 1972
Young, C.L., Equilibrium properties of octamethylcyclotetrasiloxane near its critical point and applicability of the principle of corresponding states, J. Chem. Thermodyn., 1972, 4, 65. [all data]

Voronkov, Klyuchnikov, et al., 1991
Voronkov, M.G.; Klyuchnikov, V.A.; Mironenko, E.V.; Shvets, G.N.; Danilova, T.F.; Khudobin, Yu.I., Thermochemistry of organosilicon compounds, Journal of Organometallic Chemistry, 1991, 406, 1-2, 91-97, https://doi.org/10.1016/0022-328X(91)83174-3 . [all data]

Osthoff and Grubb, 1954
Osthoff, Robert C.; Grubb, W.T., Physical Properties of Organosilicon Compounds. III. Thermodynamic Properties of Octamethylcyclotetrasiloxane, J. Am. Chem. Soc., 1954, 76, 2, 399-401, https://doi.org/10.1021/ja01631a025 . [all data]

Flaningam, 1986
Flaningam, Ora L., Vapor pressures of poly(dimethylsiloxane) oligomers, J. Chem. Eng. Data, 1986, 31, 3, 266-272, https://doi.org/10.1021/je00045a002 . [all data]

Ditsent, Skorokhodov, et al., 1971
Ditsent, V.E.; Skorokhodov, I.I.; Terent'eva, N.A.; Zolotareva, M.N., Russ. J. Phys. Chem., 1971, 45, 6, 901. [all data]

Domalski and Hearing, 1996
Domalski, Eugene S.; Hearing, Elizabeth D., Heat Capacities and Entropies of Organic Compounds in the Condensed Phase. Volume III, J. Phys. Chem. Ref. Data, 1996, 25, 1, 1, https://doi.org/10.1063/1.555985 . [all data]

Mekhtiev, Karasharli, et al., 1975
Mekhtiev, S.A.; Karasharli, K.A.; Dzhafarov, O.I., The true heat capacity of 1,1,3,3,5,5-hexamethyl-7,7-diphenylcyclotetrasiloxane in the temperature range 13 to 320 K, Zhur. Fiz. Khim., 1975, 49, 259. [all data]

Alvik, Dale, et al., 1971
Alvik, Thor; Dale, Johannes; Fernholt, L.; Hedberg, Kenneth; Schaumburg, Kjeld; Ehrenberg, L., On the Lack of Conformational Preferences for Cyclic Dimethylsiloxane Oligomers., Acta Chem. Scand., 1971, 25, 2131-2141, https://doi.org/10.3891/acta.chem.scand.25-2131 . [all data]

Richmond and Pombo-Villar, 1998
Richmond, R.; Pombo-Villar, E., Short communication. Use of persistent trace gas chromatography artifacts for the calculation of pseudo-Sadtler retention indices, J. Chromatogr. A, 1998, 811, 1-2, 241-245, https://doi.org/10.1016/S0021-9673(98)00285-4 . [all data]

Jung, Wichmann, et al., 1999
Jung, A.; Wichmann, K.-H.; Kolb, M., VOC emission of polymeric packaging materials, LaborPraxis, 1999, 23, 9, 20-22. [all data]

Fujimoto, Ohtani, et al., 1990
Fujimoto, S.; Ohtani, H.; Yamagiwa, K.; Tsuge, S., Study on retention behavior of cyclic siloxanes by high resolution pyrolysis-gas chromatography with a fused silica capillary column, J. Hi. Res. Chromatogr., 1990, 13, 6, 397-404, https://doi.org/10.1002/jhrc.1240130603 . [all data]

Kazuyoshi, Seiichi, et al., 2000
Kazuyoshi, N.; Seiichi, Y.; Kazuo, K.; Katsumi, I.; Okihiko, S., Polymer analysis by improved pyrolysis gas chromatography hyphenated with four specific detectors, J. Soc. Cosmet. Chem. Jpn., 2000, 34, 2, 142-151, https://doi.org/10.5107/sccj.34.142 . [all data]


Notes

Go To: Top, Phase change data, IR Spectrum, Mass spectrum (electron ionization), Gas Chromatography, NIST Free Links, References