1,3-Cyclopentadiene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101SqualaneSqualaneSE-54
Column length (m) 25.25.45.45.25.
Carrier gas N2N2N2N2N2
Substrate      
Column diameter (mm) 0.230.230.50.50.22
Phase thickness (μm)      
Temperature (C) 100.80.100.80.100.
I 545.542.534.7510.5552.5
ReferenceDiez, Guillen, et al., 1990Diez, Guillen, et al., 1990Diez, Guillen, et al., 1990Diez, Guillen, et al., 1990Diez, Guillen, et al., 1990
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedCapillaryCapillaryCapillary
Active phase SE-54SqualaneSqualaneBP-1BP-1
Column length (m) 25.2.50.12.12.
Carrier gas N2He N2N2
Substrate  Risorb (0.2-0.3 mm)   
Column diameter (mm) 0.22 0.250.220.22
Phase thickness (μm)      
Temperature (C) 80.70.50.100.80.
I 549.5527.521.7543.541.
ReferenceDiez, Guillen, et al., 1990Safina, Poznyak, et al., 1989Papazova, Milina, et al., 1988Bermejo, Blanco, et al., 1987Bermejo, Blanco, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101SqualaneSE-30SE-30
Column length (m) 25.25.50.100.100.
Carrier gas N2N2H2  
Substrate      
Column diameter (mm) 0.230.230.250.50.5
Phase thickness (μm)   0.25  
Temperature (C) 100.80.64.130.80.
I 545.542.523.546.540.
ReferenceBermejo, Blanco, et al., 1987Bermejo, Blanco, et al., 1987Sojak, Ruman, et al., 1987Bredael, 1982Bredael, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPackedPackedPacked
Active phase SqualaneSqualaneSqualaneSqualaneSqualane
Column length (m) 100.100.   
Carrier gas      
Substrate      
Column diameter (mm) 0.250.25   
Phase thickness (μm)      
Temperature (C) 50.50.27.49.67.
I 521.8521.6518.521.527.
ReferenceBajus, Veselý, et al., 1979Bajus, Veselý, et al., 1979, 2Bogoslovsky, Anvaer, et al., 1978Bogoslovsky, Anvaer, et al., 1978Bogoslovsky, Anvaer, et al., 1978
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedCapillaryCapillaryPackedPacked
Active phase SqualaneSqualaneSqualaneSqualaneSqualane
Column length (m)  70.100.15.15.
Carrier gas    HeHe
Substrate    Chromosorb PChromosorb P
Column diameter (mm)  0.230.250.250.25
Phase thickness (μm)      
Temperature (C) 86.40.27.27.49.
I 530.520.6516.61519.522.
ReferenceBogoslovsky, Anvaer, et al., 1978Stopp, Engewald, et al., 1978Schomburg and Dielmann, 1973Hively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase SqualaneSqualane
Column length (m) 15.15.
Carrier gas HeHe
Substrate Chromosorb PChromosorb P
Column diameter (mm) 0.250.25
Phase thickness (μm)   
Temperature (C) 67.86.
I 528.530.
ReferenceHively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Diez, Guillen, et al., 1990
Diez, M.A.; Guillen, M.D.; Blanco, C.G.; Bermejo, J., Chromatographic study of methylcyclopentadiene dimers and iso-dimers and determination of their boiling points, J. Chromatogr., 1990, 508, 363-374, https://doi.org/10.1016/S0021-9673(00)91279-2 . [all data]

Safina, Poznyak, et al., 1989
Safina, L.R.; Poznyak, T.I.; Lisitsyn, D.M.; Kiseleva, E.V.; Kovalev, G.I., Selective gas-chromatographic determination of trace unsaturated and aromatic-hydrocarbons in complex-mixtures, J. Appl. Chem. USSR (Engl. Transl.), 1989, 44, 5, 749-754. [all data]

Papazova, Milina, et al., 1988
Papazova, D.; Milina, R.; Dimov, N., Comparative evaluation of retention of hydrocarbons present in the C5-petroleum fraction of methylsilicone and squalane phases, Chromatographia, 1988, 25, 3, 177-180, https://doi.org/10.1007/BF02316441 . [all data]

Bermejo, Blanco, et al., 1987
Bermejo, J.; Blanco, C.G.; Diez, M.A.; Guillén, M.D., Kováts retention indices of selected mono and polycyclic olefins, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1987, 10, 8, 461-463, https://doi.org/10.1002/jhrc.1240100809 . [all data]

Sojak, Ruman, et al., 1987
Sojak, L.; Ruman, J.; Janak, J., Characterization of Monoalkylcyclopentadiens by Retention-Structure Correlation in Capillary Gas Chromatography, J. Chromatogr., 1987, 391, 79-87, https://doi.org/10.1016/S0021-9673(01)94306-7 . [all data]

Bredael, 1982
Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1982, 5, 6, 325-328, https://doi.org/10.1002/jhrc.1240050610 . [all data]

Bajus, Veselý, et al., 1979
Bajus, M.; Veselý, V.; Leclercq, P.A.; Rijks, J.A., Steam cracking of hydrocarbons. 2. Pyrolysis of methylcyclohexane, Ind. Eng. Chem. Prod. Res. Dev., 1979, 18, 2, 135-142, https://doi.org/10.1021/i360070a012 . [all data]

Bajus, Veselý, et al., 1979, 2
Bajus, M.; Veselý, V.; Leclercq, P.A.; Rijks, J.A., Steam cracking of hydrocarbons. 1. Pyrolysis of heptane, Ind. Eng. Chem. Prod. Res. Dev., 1979, 18, 1, 30-37, https://doi.org/10.1021/i360069a007 . [all data]

Bogoslovsky, Anvaer, et al., 1978
Bogoslovsky, Yu.N.; Anvaer, B.I.; Vigdergauz, M.S., Chromatographic constants in gas chromatography (in Russian), Standards Publ. House, Moscow, 1978, 192. [all data]

Stopp, Engewald, et al., 1978
Stopp, I.; Engewald, W.; Kühn, H.; Welsch, Th., Molekülstruktur und retentionsverhalten. VIII. Zum gaschromatographischen retentionsverhalten von dicyclopentadienderivaten, J. Chromatogr., 1978, 147, 21-30, https://doi.org/10.1016/S0021-9673(00)85113-4 . [all data]

Schomburg and Dielmann, 1973
Schomburg, G.; Dielmann, G., Identification by means of retention parameters, J. Chromatogr. Sci., 1973, 11, 3, 151-159, https://doi.org/10.1093/chromsci/11.3.151 . [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References