Lithium hydroxide


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View plot Requires a JavaScript / HTML 5 canvas capable browser.

Temperature (K) 298. to 1200.1200. to 6000.
A 42.14041112.9437
B 145.843410.11829
C -110.7379-1.899646
D 32.621060.124442
E -0.484947-13.05575
F -731.0410-774.6090
G 279.2050365.1519
H -711.2800-711.2800
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in June, 1971 Data last reviewed in June, 1971
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
298.71.17269.7269.8-0.01
300.71.42270.2269.80.13
400.81.82292.3272.77.82
500.89.52311.4278.616.41
600.95.48328.3285.525.67
700.100.2343.4292.735.46
800.103.9357.0299.945.67
900.106.9369.4306.956.21
1000.109.4380.8313.867.03
1100.111.6391.3320.378.08
1200.113.7401.1326.789.34
Temperature
(K)
Cp
(J/mol*K)

(J/mol*K)
-(G° - H°298.15)/T
(J/mol*K)
H° - H°298.15
(kJ/mol)
1200.113.5401.1326.789.34
1300.115.4410.3332.8100.8
1400.117.1418.9338.6112.4
1500.118.5427.0344.2124.2
1600.119.7434.7349.6136.1
1700.120.7442.0354.9148.1
1800.121.7448.9359.9160.2
1900.122.5455.5364.8172.5
2000.123.3461.8369.5184.8
2100.124.0467.9374.0197.1
2200.124.6473.7378.4209.6
2300.125.2479.2382.7222.0
2400.125.7484.6386.8234.6
2500.126.2489.7390.8247.2
2600.126.7494.7394.7259.8
2700.127.1499.4398.5272.5
2800.127.4504.1402.2285.3
2900.127.8508.5405.8298.0
3000.128.1512.9409.3310.8
3100.128.4517.1412.7323.6
3200.128.7521.2416.0336.5
3300.128.9525.1419.3349.4
3400.129.1529.0422.4362.3
3500.129.4532.7425.5375.2
3600.129.5536.4428.6388.1
3700.129.7539.9431.5401.1
3800.129.9543.4434.4414.1
3900.130.0546.8437.3427.1
4000.130.2550.1440.0440.1
4100.130.3553.3442.8453.1
4200.130.4556.4445.4466.2
4300.130.5559.5448.0479.2
4400.130.6562.5450.6492.3
4500.130.7565.4453.1505.3
4600.130.8568.3455.6518.4
4700.130.9571.1458.0531.5
4800.130.9573.9460.4544.6
4900.131.0576.6462.8557.7
5000.131.1579.2465.1570.8
5100.131.1581.8467.3583.9
5200.131.2584.4469.6597.0
5300.131.3586.9471.7610.1
5400.131.3589.3473.9623.3
5500.131.4591.7476.0636.4
5600.131.5594.1478.1649.5
5700.131.5596.4480.2662.7
5800.131.6598.7482.2675.8
5900.131.7601.0484.2689.0
6000.131.8603.2486.1702.2

References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References