Phenol, 2,3-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase TR-1DB-5DB-5 MSDB-1DB-1
Column length (m) 30.30.25.60.60.
Carrier gas HeliumHeliumHeliumHeHe
Substrate      
Column diameter (mm) 0.320.320.200.320.32
Phase thickness (μm) 0.250.250.330.250.25
Tstart (C) 50.40.40.35.35.
Tend (C) 300.250.250.230.230.
Heat rate (K/min) 5.8.10.2.2.
Initial hold (min)  2.1.4.4.
Final hold (min)  5. 25.25.
I 1153.1200.1132.1151.1166.
ReferenceGruzdev, Kuzivanov, et al., 2012Czerny, Brueckner, et al., 2011Majcher, Lawrowski, et al., 2010Lee, Lee, et al., 2005Lee, Lee, et al., 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillary
Active phase SPB-5BP-1Ultra-1
Column length (m) 60.50.25.
Carrier gas HeHeHe
Substrate    
Column diameter (mm) 0.320.220.32
Phase thickness (μm) 1.0.750.25
Tstart (C) 40.50.80.
Tend (C) 200.200.260.
Heat rate (K/min) 3.5.3.
Initial hold (min)    
Final hold (min)    
I 1167.1158.1147.
ReferencePoligné, Collignan, et al., 2001Health Safety Executive, 2000Okumura, 1991
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Gruzdev, Kuzivanov, et al., 2012
Gruzdev, I.V.; Kuzivanov, I.M.; Zenkevich, I.G.; Kondratenok, B.M., Gas-chromatographic identification of products formed in iodination of methyl phenols by retention indices, Rus. J. Appl. Chem., 2012, 85, 9, 1355-1365, https://doi.org/10.1134/S1070427212090108 . [all data]

Czerny, Brueckner, et al., 2011
Czerny, M.; Brueckner, R.; Kirchoff, E.; Schmitt, R.; Buettner, A., The influence of molecular structure on odor qualities and odor detection thresholds of volatile alkylated phenols, Chem. Senses, 2011, 1-15, retrieved from http://chemie.oxfordjournals.org. [all data]

Majcher, Lawrowski, et al., 2010
Majcher, M.; Lawrowski, P.; Jelen, H., Comparison of original and adulterated oscypek cheese based on volatile and sensory profiles, Acta Sci. Pol. Technol. Aliment., 2010, 9, 3, 265-275. [all data]

Lee, Lee, et al., 2005
Lee, K.-G.; Lee, S.-E.; Takeoka, G.R.; Kim, J.-H.; Park, B.-S., Antioxidant activity and characterization of volatile constituents of beechwood creosote, J. Sci. Food Agric., 2005, 85, 9, 1580-1586, https://doi.org/10.1002/jsfa.2156 . [all data]

Poligné, Collignan, et al., 2001
Poligné, I.; Collignan, A.; Trystram, G., Characterization of traditional processing of pork meat into boucané, Meat Sci., 2001, 59, 4, 377-389, https://doi.org/10.1016/S0309-1740(01)00090-0 . [all data]

Health Safety Executive, 2000
Health Safety Executive, MDHS 96 Volatile organic compounds in air - Laboratory method using pumed solid sorbent tubes, solvent desorption and gas chromatography in Methods for the Determination of Hazardous Substances (MDHS) guidance, Crown, Colegate, Norwich, 2000, 1-24, retrieved from http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs96.pdf. [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]