Benzene, 1,2,3-trimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase ZB-WaxZB-WaxCarbowax 20MPEG-20MCarbowax 20M
Column length (m) 60.60.15.30.100.
Carrier gas   HeN2N2
Substrate      
Column diameter (mm) 0.250.250.50.30.23
Phase thickness (μm) 0.250.25   
Temperature (C) 100.120.150.70.100.
I 1366.31382.91295.1325.41320.6
ReferencePérez-Parajón, Santiuste, et al., 2004Pérez-Parajón, Santiuste, et al., 2004Egazaryants and Maximov, 1998Tóth, 1983Engewald and Wennrich, 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase Carbowax 20M
Column length (m) 100.
Carrier gas  
Substrate  
Column diameter (mm) 0.2
Phase thickness (μm)  
Temperature (C) 90.
I 1301.8
ReferenceDöring, Estel, et al., 1974
Comment MSDC-RI

References

Go To: Top, Kovats' RI, polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Pérez-Parajón, Santiuste, et al., 2004
Pérez-Parajón, J.M.; Santiuste, J.M.; Takács, J.M., Sensitivity of the methylbenzenes and chlorobenzenes retention index to column temperature, stationary phase polarity, and number and chemical nature of substituents, J. Chromatogr. A, 2004, 1048, 2, 223-232, https://doi.org/10.1016/j.chroma.2004.07.028 . [all data]

Egazaryants and Maximov, 1998
Egazaryants, S.V.; Maximov, A.L., Analysis of Gasoline Fractions by Capillary GC in 20th International Symposium on Capillary Chromatography, 1998, 1-6. [all data]

Tóth, 1983
Tóth, T., Use of capillary gas chromatography in collecting retention and chemical information for the analysis of complex petrochemical mixtures, J. Chromatogr., 1983, 279, 157-165, https://doi.org/10.1016/S0021-9673(01)93614-3 . [all data]

Engewald and Wennrich, 1976
Engewald, W.; Wennrich, L., Molekülstruktur und Retentionsverhalten. VIII. Zum Retentionsverhalten höherer Alkylbenzole bei der Gas-Verteilungs-Chromatographie, Chromatographia, 1976, 9, 11, 540-547, https://doi.org/10.1007/BF02275960 . [all data]

Döring, Estel, et al., 1974
Döring, C.E.; Estel, D.; Fischer, R., Kapillar-gaschromatographische Charakterisierung von C10-bis C12-Aromaten, J. Prakt. Chem., 1974, 316, 1, 1-12, https://doi.org/10.1002/prac.19743160102 . [all data]


Notes

Go To: Top, Kovats' RI, polar column, isothermal, References