Benzene, 1,2,3-trimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneOV-101OV-101OV-101
Column length (m)   50.50.50.
Carrier gas      
Substrate      
Column diameter (mm)   0.200.200.20
Phase thickness (μm)      
Temperature (C) 100.100.100.100.120.
I 1010.1011.1016.1016.1023.
ReferenceBerezkin, 1993Berezkin, 1993Tian, 1993Tian, 1993Tian, 1993
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101E-301SqualaneSqualane
Column length (m) 50. 50.50. 
Carrier gas   N2N2H2
Substrate      
Column diameter (mm) 0.20 0.250.25 
Phase thickness (μm)      
Temperature (C) 120.70.100.100.95.4
I 1023.1010.1020.1016.1007.
ReferenceTian, 1993Wu and Lu, 1984Bermejo, Moinelo, et al., 1980Bermejo, Moinelo, et al., 1980Sojak and Vigdergauz, 1978
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase Squalane
Column length (m) 100.
Carrier gas N2
Substrate  
Column diameter (mm) 0.25
Phase thickness (μm)  
Temperature (C) 110.
I 1016.
ReferencePapazova and Pankova, 1975
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Berezkin, 1993
Berezkin, V.G., Linear correlation between retention indexes obtained in different laboratories on open tubular capillary columns with the same liquid stationary phase, Chem. Anal. (Warsaw), 1993, 38, 5, 649-651. [all data]

Tian, 1993
Tian, S., Analysis of the tower bottom oil of dimethylbenzene rectifying tower and C9 aromatic hydrocarbon fraction by capillary gas chromatography, Chin. J. Chromatogr., 1993, 11, 4, 202-206. [all data]

Wu and Lu, 1984
Wu, J.; Lu, W., Kovats indices of C4-C10 hydrocarbons in apolar quartz capillary OV-101, Chin. J. Chromatogr., 1984, 1, 1, 11-17. [all data]

Bermejo, Moinelo, et al., 1980
Bermejo, J.; Moinelo, S.R.; Suarez Canga, C., Calculo de indices de retencion a patir de DI y de la polaridad de la fase, Calculo de indices de retencion a patir de DI y de la polaridad de la fase, Instituto Nacional del Carbon y sus Derivados Francisco Pintado Fe (INCAR), La Corredoria, Oviedo, Espana, 1980, 13. [all data]

Sojak and Vigdergauz, 1978
Sojak, L.; Vigdergauz, M.S., Comparison of interpolation methods for the interpretation of retention data in gas chromatography, J. Chromatogr., 1978, 148, 1, 159-167, https://doi.org/10.1016/S0021-9673(00)99332-4 . [all data]

Papazova and Pankova, 1975
Papazova, D.I.; Pankova, M.C., Identification of individual aromatic hydrocarbons in kerosene fraction (b.p. 150-250 °), J. Chromatogr., 1975, 105, 2, 411-414, https://doi.org/10.1016/S0021-9673(01)82276-7 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, isothermal, References