Cyclobarbital


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryOther
Active phase HP-1CP Sil 5 CBCP Sil 5 CBOV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.Methyl Silicone
Column length (m)  10.10.50. 
Carrier gas Helium  Hydrogen 
Substrate      
Column diameter (mm)  0.530.530.32 
Phase thickness (μm)  5.25.2  
Program not specified100 0C (2 min) 20 0C/min -> 180 0C 7.5 0C/min -> 280 0C (6 min)not specifiednot specifiednot specified
I 1970.1970.1960.1973.1963.
ReferenceGrigor'ev, Bozhko, et al., 2009Bogusz, Bialka, et al., 1986Bogusz, Bialka, et al., 1986Waggott and Davies, 1984Ardrey and Moffat, 1981
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase OV-101OV-101
Column length (m) 2.2.
Carrier gas NitrogenNitrogen
Substrate Chromosorb G (100-120 mesh)Chromosorb G (100-120 mesh)
Column diameter (mm)   
Phase thickness (μm)   
Program not specifiednot specified
I 1959.1950.
ReferenceDubsky, Hána, et al., 1978Dubsky, Hána, et al., 1978
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Grigor'ev, Bozhko, et al., 2009
Grigor'ev, A.M.; Bozhko, E.S.; Rudakova, L.V., Use of correlation between retention indices on low-polarity phases for screening comp-lex mixtures by gas chromatography-mass spectrometry, Rus. J. Anal. Chem., 2009, 64, 2, 140-143, https://doi.org/10.1134/S1061934809020087 . [all data]

Bogusz, Bialka, et al., 1986
Bogusz, M.; Bialka, J.; Gierz, J.; Klys, M., Use of short, wide-bore capillary columns in GC toxicological screening, J. Anal. Toxicol., 1986, 10, 4, 135-138, https://doi.org/10.1093/jat/10.4.135 . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]

Ardrey and Moffat, 1981
Ardrey, R.E.; Moffat, A.C., Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase, J. Chromatogr., 1981, 220, 3, 195-252, https://doi.org/10.1016/S0021-9673(00)81925-1 . [all data]

Dubsky, Hána, et al., 1978
Dubsky, H.; Hána, K.; Komárková, M.; Rittich, B., Pouzití kovatsovych indexu pri toxikologickych analysách, Chem. Listy, 1978, 72, 980-984. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References