Column type CapillaryCapillaryCapillaryPackedCapillary
Active phase BP-1DB-1BP-1SE-30SPB-1
Column length (m) 25.30.25.2.25.
Carrier gas N2N2N2N2He
Substrate    1% se-30 on Anachrom ABS(80-100mesh) 
Column diameter (mm) 0.220.530.53 0.20
Phase thickness (mum) 0.251.51.  
Temperature (C) 200.200.200.220.250.
I 2182.2194.2188.2201.2236.
ReferenceJapp, Gill, et al., 1987Japp, Gill, et al., 1987Japp, Gill, et al., 1987Musumarra, Scarlata, et al., 1987Lora-Tamayo, Rams, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Packed
Active phase OV-1
Column length (m)  
Carrier gas  
Substrate  
Column diameter (mm)  
Phase thickness (mum)  
Temperature (C) 200.
I 2185.
ReferenceBerninger and Möller, 1977
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Japp, Gill, et al., 1987
Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 1987, 32, 6, 1574-1586. [all data]

Musumarra, Scarlata, et al., 1987
Musumarra, G.; Scarlata, G.; Romano, G.; Cappello, G.; Clementi, S.; Giulietti, G., Qualitative organic analysis. Part 2. Identification of drugs by principal components analysis of standardized TLC data in four eluent systems and of retention indices on SE 30, J. Anal. Toxicol., 1987, 11, 4, 154-163, https://doi.org/10.1093/jat/11.4.154 . [all data]

Lora-Tamayo, Rams, et al., 1986
Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 1986, 374, 73-85, https://doi.org/10.1016/S0378-4347(00)83254-5 . [all data]

Berninger and Möller, 1977
Berninger, H.; Möller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 1977, 37, 4, 295-305, https://doi.org/10.1007/BF00330821 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References