Cocaine


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryPackedCapillaryPacked
Active phase BP-1BP-1SE-30SPB-1SE-30
Column length (m) 25.25.2.25.2.
Carrier gas N2N2N2He 
Substrate   1% se-30 on Anachrom ABS(80-100mesh) Anakrom ABS
Column diameter (mm) 0.220.53 0.20 
Phase thickness (μm) 0.251.   
Temperature (C) 200.200.220.250.220.
I 2177.2184.2185.2233.2200.
ReferenceJapp, Gill, et al., 1987Japp, Gill, et al., 1987Musumarra, Scarlata, et al., 1987Lora-Tamayo, Rams, et al., 1986Mari, Bertol, et al., 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPacked
Active phase SE-30OV-1
Column length (m) 2. 
Carrier gas   
Substrate Anakrom ABS 
Column diameter (mm)   
Phase thickness (μm)   
Temperature (C) 260.200.
I 2235.2180.
ReferenceMari, Bertol, et al., 1984Berninger and Möller, 1977
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Japp, Gill, et al., 1987
Japp, M.; Gill, R.; Osselton, M.D., Comparison of drug retention indices determined on packed, wide bore capillary and narrow bore capillary columns, J. Forensic Sci., 1987, 32, 6, 1574-1586. [all data]

Musumarra, Scarlata, et al., 1987
Musumarra, G.; Scarlata, G.; Romano, G.; Cappello, G.; Clementi, S.; Giulietti, G., Qualitative organic analysis. Part 2. Identification of drugs by principal components analysis of standardized TLC data in four eluent systems and of retention indices on SE 30, J. Anal. Toxicol., 1987, 11, 4, 154-163, https://doi.org/10.1093/jat/11.4.154 . [all data]

Lora-Tamayo, Rams, et al., 1986
Lora-Tamayo, C.; Rams, M.A.; Chacon, J.M.R., Gas Chromatographic Data for 187 Nitrogen- or Phosphorus-Containing Drugs and Metabolites of Toxicological Interest Analysed on Methyl Silicone Capillary Columns, J. Chromatogr., 1986, 374, 73-85, https://doi.org/10.1016/S0378-4347(00)83254-5 . [all data]

Mari, Bertol, et al., 1984
Mari, F.; Bertol, E.; Tosti, M., Benzoyltropeine, an unusual substance in street heroin samples, Bull. Narc., 1984, 1, 59-67. [all data]

Berninger and Möller, 1977
Berninger, H.; Möller, M.R., Retentionsindices zur gaschromatographischen Identifizierung von Arzneimitteln, Arch. Toxicol., 1977, 37, 4, 295-305, https://doi.org/10.1007/BF00330821 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References