Cocaine


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedCapillaryCapillaryCapillary
Active phase Polydimethyl siloxaneSE-30Polymethylsiloxane, (PMS-20000)DB-5BP-1
Column length (m) 2.2.12.15.12.
Carrier gas NitrogenNitrogenHeHeHe
Substrate  Chromosorb G AW DMCS (80-100 mesh)   
Column diameter (mm)   0.200.250.22
Phase thickness (μm)   0.330.20.25
Tstart (C) 100.100.160.185.100.
Tend (C) 300.300.300.270.295.
Heat rate (K/min)   10.10.5.
Initial hold (min)      
Final hold (min)      
I 2187.2187.2187.2163.2161.
ReferenceMHA, 9999MHA, 9999Gambaro, Saligari, et al., 1997Phillips, Logan, et al., 1990Stowell and Wilson, 1985
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPackedPackedPacked
Active phase BP-1BP-1OV-1SE-30SE-30
Column length (m) 12.12.2.2.2.
Carrier gas HeHe NitrogenN2
Substrate   Gas Chrom PChromosorb W AW DMS (80-100 mesh)Chromosorb W AW DMS
Column diameter (mm) 0.220.22   
Phase thickness (μm) 0.250.25   
Tstart (C) 120.50.120.130.130.
Tend (C) 280.300.200.290.290.
Heat rate (K/min) 8.20.2.58.8.
Initial hold (min)    2.2.
Final hold (min)    8.8.
I 2175.2176.2190.2187.2187.
ReferenceStowell and Wilson, 1985Stowell and Wilson, 1985Marozzi, Gambaro, et al., 1982Peel and Perrigo, 1976Peel and Perrigo, 1975
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

MHA, 9999
MHA, Directorate of ForensicScience., Forensic Toxicology, 9999. [all data]

Gambaro, Saligari, et al., 1997
Gambaro, V.; Saligari, E.; Froldi, R.; Bianchi, L., Analysis of street drugs by means of HRGC, Bollettino Chimico Farmaceutica, 1997, 36, 4, 359-367. [all data]

Phillips, Logan, et al., 1990
Phillips, A.M.; Logan, B.K.; Stafford, D.T., Further applications for capillary gas chromatography in routine quantitative toxicological analyses, J. Hi. Res. Chromatogr., 1990, 13, 11, 754-758, https://doi.org/10.1002/jhrc.1240131106 . [all data]

Stowell and Wilson, 1985
Stowell, A.; Wilson, L., Use of retention indices in drug screening by capillary gas chromatography, Rep. # CD 2362, Department of Scientific and Industrial Reseach, Chemistry Division, Lower Hutt, NZ, 1985, 32. [all data]

Marozzi, Gambaro, et al., 1982
Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F., Use of the retention index in gas chromatographic studies of drugs, J. Anal. Toxicol., 1982, 6, 4, 185-192, https://doi.org/10.1093/jat/6.4.185 . [all data]

Peel and Perrigo, 1976
Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can. Soc. Forens. Sci. J., 1976, 9, 2, 69-74, https://doi.org/10.1080/00085030.1976.10757247 . [all data]

Peel and Perrigo, 1975
Peel, H.W.; Perrigo, B., A practical gas chromatographic screening procedure for toxicological analysis, Can.Soc.Forens.Sci.J., 1975, 9, 2, 69-74, https://doi.org/10.1080/00085030.1976.10757247 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References