p,p'-DDT
- Formula: C14H9Cl5
- Molecular weight: 354.486
- IUPAC Standard InChIKey: YVGGHNCTFXOJCH-UHFFFAOYSA-N
- CAS Registry Number: 50-29-3
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: Benzene, 1,1'-(2,2,2-trichloroethylidene)bis[4-chloro-; Chlorophenothane; α,α-Bis(p-chlorophenyl)-β,β,β-trichlorethane; p,p'-Dichlorodiphenyltrichloroethane; Aavero-extra; Agritan; Arkotine; Azotox; Azotox M-33; Bosan supra; Bovidermol; Chlorphenothan; Chlorphenotoxum; Citox; Clofenotan; Clofenotane; Deoval; Detox; Detoxan; Dibovin; Dicophane; Dodat; Dykol; DDT; Estonate; Ethane, 1,1,1-Trichloro-2,2-bis(p-chlorophenyl)-; Ethane, 1,1,1-trichloro-2,2-bis(4-chlorophenyl)-; ENT-1506; Gesafid; Gesarol; Ivoran; Mutoxan; Neocid; Neocidol, Solid; Parachlorocidum; Pentachlorin; Penticidum; PEB1; Trichlorobis(4'-Chlorophenyl)ethane; Zerdane; 1,1,1-Trichloro-2,2-bis(p-chlorophenyl)ethane; 1,1,1-Trichloro-2,2-bis(4,4'-dichlorodiphenyl)ethane; 2,2-Bis(p-chlorophenyl)-1,1,1-trichloroethane; 4,4'-Dichlorodiphenyltrichloroethane; 4,4'-DDT; 1,1-Bis(4-chlorophenyl)-2,2,2-trichloroethane; 1,1,1-trichloro-2-2-bis(4-chlorophenyl)ethane; Anofex; Didigam; Didimac; Genitox; Guesarol; Gyron; Ixodex; Kopsol; Neocidol; NCI-C00464; Pentech; pPzeidan; Rukseam; Santobane; Tafidex; Trichlorobis(4-chlorophenyl)ethane; Zeidane; 1,1,1-Trichloor-2,2-bis(4-chloor fenyl)-ethaan; 1,1,1-Trichlor-2,2-bis(4-chlor-phenyl)-aethan; 1,1,1-Trichloro-2,2-di(4-chlorophenyl)ethane; 1,1,1-Tricloro-2,2-bis(4-cloro-fenil)-etano; Chlorophenothan; Chlorophenotoxum; Dedelo; Dibovan; ENT 1,506; Gesapon; Gesarex; Guesapon; Havero-extra; Hildit; Micro DDT 75; Mutoxin; OMS 16; R50; RCRA Waste number U061; Penticide; 2,2,2-Trichloro-1,1-bis(4-chlorophenyl)ethane; p,p'-Dichlorodiphenyltrichloromethylmethane; 1,1'-(2,2,2,-Trichloroethylidene)bis[4-chlorobenzene]; Geusapon; 1,1-bis(p-Chlorophenyl)-2,2,2-trichIoroethane; DDT(p,p'); Dicophaner; Benzochloryl; p,p-DDT; 1,1,1-Trichloro-2,2-bis(4-chlorophenyl)ethane (pp'DDT)
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Gas Chromatography
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Kovats' RI, non-polar column, isothermal
Column type | Active phase | Temperature (C) | I | Reference | Comment |
---|---|---|---|---|---|
Capillary | OV-1 | 190. | 2289. | Erdmann, Rochholz, et al., 1992 | |
Capillary | OV-1 | 220. | 2301. | Erdmann, Rochholz, et al., 1992 | |
Packed | Apiezon L | 215. | 2284. | Heinzen and Yunes, 1992 | Chromosorb W; Column length: 1.8 m |
Packed | OV-1 | 200. | 2284. | Dubsky, Hána, et al., 1979 | Column length: 2. m |
Kovats' RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Packed | SE-30 | 2330. | Osselton and Snelling, 1986 | N2, Chromosorb W HP; Column length: 2. m; Program: not specified |
Packed | SE-30 | 2290. | Ramsey, Lee, et al., 1980 | He, Chromosorb G HP (80-100 mesh); Column length: 1.5 m; Program: not specified |
Van Den Dool and Kratz RI, non-polar column, temperature ramp
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | OV-1 | 2325.2 | Gautzsch and Zinn, 1996 | 8. K/min; Tstart: 35. C; Tend: 300. C |
Capillary | OV-1 | 2263. | de Paoli, Taccheo-Barbina, et al., 1991 | 25. m/0.32 mm/0.10 μm, 160. C @ 1. min, 1. K/min; Tend: 240. C |
Capillary | OV-1 | 2270. | de Paoli, Taccheo-Barbina, et al., 1991 | 25. m/0.32 mm/0.10 μm, 160. C @ 1. min, 1. K/min; Tend: 240. C |
Capillary | OV-1 | 2277. | de Paoli, Taccheo-Barbina, et al., 1991 | 25. m/0.32 mm/0.10 μm, 160. C @ 1. min, 1.3 K/min; Tend: 240. C |
Capillary | OV-1 | 2264. | de Paoli, Taccheo-Barbina, et al., 1991 | 25. m/0.32 mm/0.10 μm, 160. C @ 1. min, 1.5 K/min; Tend: 240. C |
Capillary | OV-1 | 2270. | de Paoli, Taccheo-Barbina, et al., 1991 | 25. m/0.32 mm/0.10 μm, 160. C @ 1. min, 1.5 K/min; Tend: 240. C |
Capillary | OV-1 | 2277. | de Paoli, Taccheo-Barbina, et al., 1991 | 25. m/0.32 mm/0.10 μm, 160. C @ 1. min, 2. K/min; Tend: 240. C |
Capillary | CP Sil 5 CB | 2264. | Wells, Gillespie, et al., 1985 | 120. C @ 1. min, 3. K/min; Column length: 25. m; Column diameter: 0.22 mm; Tend: 250. C |
Packed | SE-30 | 2300. | Perrigo and Peel, 1981 | N2, Chromosorb W, 130. C @ 2. min, 8. K/min, 290. C @ 8. min; Column length: 1.8 m |
Normal alkane RI, non-polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Ultra-1 | 2270. | Tameo and Kiyos, 1991 | Program: not specified |
Capillary | OV-1 | 2300. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Capillary | OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc. | 2290. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Capillary | OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc. | 2300. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Other | Methyl Silicone | 2299. | Ardrey and Moffat, 1981 | Program: not specified |
Normal alkane RI, polar column, custom temperature program
Column type | Active phase | I | Reference | Comment |
---|---|---|---|---|
Capillary | Superox 0.6; Carbowax 20M | 3106. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Capillary | Carbowax 400, Carbowax 20M, Carbowax 1540, Carbowax 4000, Superox 06, PEG 20M, etc. | 3106. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Capillary | Superox 0.6; Carbowax 20M | 3103. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
Capillary | Carbowax 400, Carbowax 20M, Carbowax 1540, Carbowax 4000, Superox 06, PEG 20M, etc. | 3103. | Waggott and Davies, 1984 | Hydrogen; Column length: 50. m; Column diameter: 0.32 mm; Program: not specified |
References
Go To: Top, Gas Chromatography, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Erdmann, Rochholz, et al., 1992
Erdmann, F.; Rochholz, G.; Schütz, H.,
Retention-indices on OV-1 of approximately 170 commonly used pesticides,
Mikrochim. Acta, 1992, 106, 3-6, 219-226, https://doi.org/10.1007/BF01242093
. [all data]
Heinzen and Yunes, 1992
Heinzen, V.E.F.; Yunes, R.A.,
Relationship between gas chromatographic retention indices and molecular connectivity indices of chlorinated pesticides and structurally related compounds,
J. Chromatogr., 1992, 598, 2, 243-250, https://doi.org/10.1016/0021-9673(92)85054-W
. [all data]
Dubsky, Hána, et al., 1979
Dubsky, H.; Hána, K.; Komárková, M.; Rittich, B.,
Stanoveni residui chlórovanych pesticidu plynovou chromatografii,
Vet. Med. (Prague), 1979, 24, 3, 493-498. [all data]
Osselton and Snelling, 1986
Osselton, M.D.; Snelling, R.D.,
Chromatographic Identification of Pesticides,
J. Chromatogr., 1986, 368, 265-271, https://doi.org/10.1016/S0021-9673(00)91068-9
. [all data]
Ramsey, Lee, et al., 1980
Ramsey, J.D.; Lee, T.D.; Osselton, M.D.; Moffat, A.C.,
Gas-liquid chromatographic retention indices of 296 non-drug substances on SE-30 or OV-1 likely to be encountered in toxicological analyses,
J. Chromatogr., 1980, 184, 2, 185-206, https://doi.org/10.1016/S0021-9673(00)85641-1
. [all data]
Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P.,
Use of incremental models to estimate the retention indexes of aromatic compounds,
Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946
. [all data]
de Paoli, Taccheo-Barbina, et al., 1991
de Paoli, M.; Taccheo-Barbina, M.; Bontempelli, G.,
Gas chromatographic system for the identification of halogenated pesticides by retention indices using n-alkanes as standards,
J. Chromatogr., 1991, 547, 355-365, https://doi.org/10.1016/S0021-9673(01)88659-3
. [all data]
Wells, Gillespie, et al., 1985
Wells, D.E.; Gillespie, M.J.; Porter, A.E.A.,
Dichlorobenzyl alkyl ether homologs as retention index markers and internal standards for the analysis of environmental samples using capillary gas chromatography,
J. Hi. Res. Chromatogr. Chromatogr. Comm., 1985, 8, 8, 443-449, https://doi.org/10.1002/jhrc.1240080818
. [all data]
Perrigo and Peel, 1981
Perrigo, B.J.; Peel, H.W.,
The use of retention indices and temperature-programmed gas chromatography in analytical toxicology,
J. Chromatogr. Sci., 1981, 19, 5, 219-226, https://doi.org/10.1093/chromsci/19.5.219
. [all data]
Tameo and Kiyos, 1991
Tameo, O.; Kiyos, I.,
Simultaneous determination of pesticides by capillary gas chromatography,
Cannot be traslated (in Japan), 1991, 14, 2, 109-122. [all data]
Waggott and Davies, 1984
Waggott, A.; Davies, I.W.,
Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]
Ardrey and Moffat, 1981
Ardrey, R.E.; Moffat, A.C.,
Gas-liquid chromatographic retention indices of 1318 substances of toxicological interest on SE-30 or OV-1 stationary phase,
J. Chromatogr., 1981, 220, 3, 195-252, https://doi.org/10.1016/S0021-9673(00)81925-1
. [all data]
Notes
Go To: Top, Gas Chromatography, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.