Naphthalene, decahydro-, cis-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryPackedPackedCapillary
Active phase HP-1HP-1OV-101SE-30OV-101
Column length (m) 25.25.2.43.85.
Carrier gas N2N2HeArN2
Substrate   Chromaton W AWGas Chrom Q (80-100 mesh) 
Column diameter (mm) 0.200.20  0.28
Phase thickness (μm)      
Temperature (C) 100.100.120.150.100.
I 1096.1096.1109.1130.1097.
ReferenceZhang, Li, et al., 1992Zhang, Li, et al., 1992Litvinenko, Isakova, et al., 1988Tiess, 1984Boneva, Papazova, et al., 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101SE-30SE-30
Column length (m) 85.85.85.15.100.
Carrier gas N2N2N2N2 
Substrate      
Column diameter (mm) 0.280.280.280.250.5
Phase thickness (μm)      
Temperature (C) 100.110.90.70.130.
I 1097.1102.1090.1081.51120.
ReferenceBoneva, Papazova, et al., 1983Boneva, Papazova, et al., 1983Boneva, Papazova, et al., 1983Tóth, 1983Bredael, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SE-30SqualaneSqualaneOV-101
Column length (m) 100.100.50.50.50.
Carrier gas   N2N2N2
Substrate      
Column diameter (mm) 0.50.50.250.250.3
Phase thickness (μm)      
Temperature (C) 150.80.86.96.140.
I 1132.1087.1101.41106.21124.8
ReferenceBredael, 1982Bredael, 1982Macák, Nabivach, et al., 1982Macák, Nabivach, et al., 1982Gerasimenko, Kirilenko, et al., 1981
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101SqualaneSqualaneSqualaneSqualane
Column length (m) 50.50.50.100.50.
Carrier gas N2  N2H2
Substrate      
Column diameter (mm) 0.30.250.250.230.2
Phase thickness (μm)      
Temperature (C) 160.86.96.90.100.
I 1137.71101.41106.21100.1114.
ReferenceGerasimenko, Kirilenko, et al., 1981Nabivach, Bur'yan, et al., 1978Nabivach, Bur'yan, et al., 1978Engewald, Epsch, et al., 1976Mitra, Mohan, et al., 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPacked
Active phase SqualaneMethyl Silicone
Column length (m)   
Carrier gas   
Substrate   
Column diameter (mm)   
Phase thickness (μm)   
Temperature (C) 120.130.
I 1119.1106.
ReferenceSchomburg, 1966Antheaume and Guiochon, 1965
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Zhang, Li, et al., 1992
Zhang, M.J.; Li, S.D.; Chen, B.J., Compositional studies of high-temperature coal tar by GC/FTIR analysis of light oil fractions, Chromatographia, 1992, 33, 3/4, 138-146, https://doi.org/10.1007/BF02275894 . [all data]

Litvinenko, Isakova, et al., 1988
Litvinenko, G.S.; Isakova, L.A.; Rubanyk, N.N., Quantitative correlation between structure of stereoisomeric saturated cyclic compounds and gas-chromatographic retention indices. I. Methysubstituted, Izv. AN Kaz. SSR, Ser. Khim., 1988, 5, 54-66. [all data]

Tiess, 1984
Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]

Boneva, Papazova, et al., 1983
Boneva, St.; Papazova, D.; Dimov, N., Retention Indices of aromatic hydrocarbons on glass and metal capillary columns with stationary phase OV-101, Jahrb. Chem. Tech. Hochschule Burgas, 1983, 18, 143-148. [all data]

Tóth, 1983
Tóth, T., Use of capillary gas chromatography in collecting retention and chemical information for the analysis of complex petrochemical mixtures, J. Chromatogr., 1983, 279, 157-165, https://doi.org/10.1016/S0021-9673(01)93614-3 . [all data]

Bredael, 1982
Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1982, 5, 6, 325-328, https://doi.org/10.1002/jhrc.1240050610 . [all data]

Macák, Nabivach, et al., 1982
Macák, J.; Nabivach, V.; Buryan, P.; Sindler, S., Dependence of retention indices of alkylbenzenes on their molecular structure, J. Chromatogr., 1982, 234, 2, 285-302, https://doi.org/10.1016/S0021-9673(00)81867-1 . [all data]

Gerasimenko, Kirilenko, et al., 1981
Gerasimenko, V.A.; Kirilenko, A.V.; Nabivach, V.M., Capillary gas chromatography of aromatic compounds found in coal tar fractions, J. Chromatogr., 1981, 208, 1, 9-16, https://doi.org/10.1016/S0021-9673(00)87953-4 . [all data]

Nabivach, Bur'yan, et al., 1978
Nabivach, V.M.; Bur'yan, P.; Matsak, I., Retention indices of aromatic hydrocarbons on a squalane capillary column, Zh. Anal. Khim., 1978, 33, 7, 1108-1113. [all data]

Engewald, Epsch, et al., 1976
Engewald, W.; Epsch, K.; Welsch, Th.; Graefe, J., Molekülstruktur und Retentionsverhalten. VI. Retentionsverhalten von bicycle[n.m.0]alkanen bei der gas-adsorptions- und gas-verteilungs-chromatographie, J. Chromatogr., 1976, 119, 119-128, https://doi.org/10.1016/S0021-9673(00)86776-X . [all data]

Mitra, Mohan, et al., 1974
Mitra, G.D.; Mohan, G.; Sinha, A., Gas chromatographic analysis of complex hydrocarbon mixtures, J. Chromatogr. A, 1974, 91, 633-648, https://doi.org/10.1016/S0021-9673(01)97944-0 . [all data]

Schomburg, 1966
Schomburg, G., Gaschromatographische Retentionsdaten und struktur chemischer verbindungen. III. Alkylverzweigte und ungesättigte cyclische Kohlenwasserstoffe, J. Chromatogr., 1966, 23, 18-41, https://doi.org/10.1016/S0021-9673(01)98653-4 . [all data]

Antheaume and Guiochon, 1965
Antheaume, J.; Guiochon, G., Application de la chromatographie en phase gazeuse à l'étude de la composition des fractions moyennes d'un brut pétrolier, Bull. Soc. Chim. Fr., 1965, 2, 298-307. [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References