Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

1H-Indene, octahydro-, cis-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type PackedPackedPackedPackedPacked
Active phase C78, Branched paraffinSE-30C78, Branched paraffinOV-101OV-101
Column length (m) 3.30.253.32.2.
Carrier gas HeHe N2N2
Substrate  Gas Chrom Q (100-120 mesh)Chromosorb G HPChromosorb G HPChromosorb W AW DMCS (80-100 mesh)
Column diameter (mm)      
Phase thickness (mum)      
Temperature (C) 130.120.130.150.120.
I 1035.6998.1033.11012.71004.
ReferenceDallos, Sisak, et al., 2000Kowalski, 1992Reddy, Dutoit, et al., 1992Maeck, Touabet, et al., 1989Fernández-Sánchez, Fernández-Torres, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSE-30SE-30SE-30SE-30
Column length (m) 3.515.100.100.100.
Carrier gas N2N2   
Substrate      
Column diameter (mm)  0.250.50.50.5
Phase thickness (mum)      
Temperature (C) 80.70.130.150.80.
I 989.980.91012.1022.987.
ReferenceKersten and Poole, 1987Tóth, 1983Bredael, 1982Bredael, 1982Bredael, 1982
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase Squalane
Column length (m) 100.
Carrier gas N2
Substrate  
Column diameter (mm) 0.23
Phase thickness (mum)  
Temperature (C) 90.
I 991.
ReferenceEngewald, Epsch, et al., 1976
Comment MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Dallos, Sisak, et al., 2000
Dallos, A.; Sisak, A.; Kulcsár, Z.; Kováts, E., Pair-wise interactions by gas chromatography VII. Interaction free enthalpies of solutes with secondary alcohol groups, J. Chromatogr. A, 2000, 904, 2, 211-242, https://doi.org/10.1016/S0021-9673(00)00908-0 . [all data]

Kowalski, 1992
Kowalski, W.J., Free radical crosslinking of the gas chromatographic stationary phase containing europium chelates, Chromatographia, 1992, 34, 5-8, 266-268, https://doi.org/10.1007/BF02268356 . [all data]

Reddy, Dutoit, et al., 1992
Reddy, K.S.; Dutoit, J.-Cl.; Kovats, E. sz., Pair-wise interactions by gas chromatography. I. Interaction free enthalpies of solutes with non-associated primary alcohol groups, J. Chromatogr., 1992, 609, 1-2, 229-259, https://doi.org/10.1016/0021-9673(92)80167-S . [all data]

Maeck, Touabet, et al., 1989
Maeck, M.; Touabet, A.; Badjah Hadj Ahmed, A.Y.; Meklati, B.Y., A numerical interpolation of Kováts indices without dead time correction, Chromatographia, 1989, 27, 5/6, 205-208, https://doi.org/10.1007/BF02260447 . [all data]

Fernández-Sánchez, Fernández-Torres, et al., 1987
Fernández-Sánchez, E.; Fernández-Torres, A.; García-Domínguez, J.A.; García-Muñoz, J.; Menéndez, V.; Molera, M.J.; Santiuste, J.M.; Pertierra-Rimada, E., Mixed stationary phases in gas-liquid chromatography. Partition coefficients and retention indices in OV-101-OV-25, OV-101-Carbowax 20M and OV-225-SP-2340 mixtures, J. Chromatogr., 1987, 410, 13-29, https://doi.org/10.1016/S0021-9673(00)90031-1 . [all data]

Kersten and Poole, 1987
Kersten, B.R.; Poole, C.F., Influence of concurrent retention mechanisms on the determination of stationary phase selectivity in gas chromatography, J. Chromatogr., 1987, 399, 1-31, https://doi.org/10.1016/S0021-9673(00)96108-9 . [all data]

Tóth, 1983
Tóth, T., Use of capillary gas chromatography in collecting retention and chemical information for the analysis of complex petrochemical mixtures, J. Chromatogr., 1983, 279, 157-165, https://doi.org/10.1016/S0021-9673(01)93614-3 . [all data]

Bredael, 1982
Bredael, P., Retention indices of hydrocarbons on SE-30, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1982, 5, 6, 325-328, https://doi.org/10.1002/jhrc.1240050610 . [all data]

Engewald, Epsch, et al., 1976
Engewald, W.; Epsch, K.; Welsch, Th.; Graefe, J., Molekülstruktur und Retentionsverhalten. VI. Retentionsverhalten von bicycle[n.m.0]alkanen bei der gas-adsorptions- und gas-verteilungs-chromatographie, J. Chromatogr., 1976, 119, 119-128, https://doi.org/10.1016/S0021-9673(00)86776-X . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References