Resorcinol, 2TMS derivative


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase DB-5DB-5DB-5PE-5htPE-5ht
Column length (m) 30.30.30.30.30.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.250.10.1
Tstart (C) 50.50.50.50.50.
Tend (C) 320.320.320.320.320.
Heat rate (K/min) 3.3.3.3.3.
Initial hold (min)      
Final hold (min)      
I 1389.1389.1390.1386.1387.
ReferenceJaroszynska and Ligor, 2005Jaroszynska and Ligor, 2005Jaroszynska and Ligor, 2005Jaroszynska and Ligor, 2005Jaroszynska and Ligor, 2005
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PE-5htPE-5msDB-5DB-5DB-5
Column length (m) 30.30.30.30.30.
Carrier gas HeHeHeHeHe
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.10.250.250.250.25
Tstart (C) 50.50.50.50.50.
Tend (C) 320.320.240.240.240.
Heat rate (K/min) 3.3.3.3.7.
Initial hold (min)      
Final hold (min)      
I 1389.1378.1389.1390.1388.
ReferenceJaroszynska and Ligor, 2005Jaroszynska and Ligor, 2005Jaroszynska, 2003Jaroszynska, 2003Jaroszynska, 2003
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPacked
Active phase DB-5OV-1
Column length (m) 30.2.
Carrier gas HeN2
Substrate  Supelcoport
Column diameter (mm) 0.25 
Phase thickness (μm) 0.25 
Tstart (C) 50.80.
Tend (C) 240.240.
Heat rate (K/min) 7.4.
Initial hold (min)   
Final hold (min)   
I 1390.1378.
ReferenceJaroszynska, 2003Mattsson and Petersson, 1977
Comment MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Jaroszynska and Ligor, 2005
Jaroszynska, J.; Ligor, T., The identification of phenolic compounds by a gas chromatographic method on three capillary columns with the same non-polar stationary phase, Anal. Chim. Acta., 2005, 539, 1-2, 11-15, https://doi.org/10.1016/j.aca.2005.03.024 . [all data]

Jaroszynska, 2003
Jaroszynska, J., Isolation of free phenolic compounds from arboreal leaves by use of the Florisil/C18 system, Anal. Bioanal. Chem., 2003, 377, 4, 702-708, https://doi.org/10.1007/s00216-003-2155-z . [all data]

Mattsson and Petersson, 1977
Mattsson, M.; Petersson, G., Reference GLC Data for the Analysis of Phenolic Compounds as Trimethylsilyl Derivatives, J. Chromatogr. Sci., 1977, 15, 12, 546-554, https://doi.org/10.1093/chromsci/15.12.546 . [all data]