Cyclohexane, octadecyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Phase change data

Go To: Top, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled as indicated in comments:
TRC - Thermodynamics Research Center, NIST Boulder Laboratories, Chris Muzny director
AC - William E. Acree, Jr., James S. Chickos

Quantity Value Units Method Reference Comment
Tfus314.8KN/ABoelhouwer, Nederbragt, et al., 1950Uncertainty assigned by TRC = 0.5 K; TRC
Tfus314.7KN/AMazee, 1948Uncertainty assigned by TRC = 0.1 K; TRC
Tfus314.15KN/AHetling and Shchekin, 1943Uncertainty assigned by TRC = 2. K; TRC
Tfus316.4KN/ALarsen, Thorpe, et al., 1942Uncertainty assigned by TRC = 2. K; TRC

Enthalpy of vaporization

ΔvapH (kJ/mol) Temperature (K) Reference Comment
100.3437.Dykyj, Svoboda, et al., 1999Based on data from 422. - 675. K.; AC

In addition to the Thermodynamics Research Center (TRC) data available from this site, much more physical and chemical property data is available from the following TRC products:


Mass spectrum (electron ionization)

Go To: Top, Phase change data, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

Due to licensing restrictions, this spectrum cannot be downloaded.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin Japan AIST/NIMC Database- Spectrum MS-NW-6125
NIST MS number 233255

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


References

Go To: Top, Phase change data, Mass spectrum (electron ionization), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Boelhouwer, Nederbragt, et al., 1950
Boelhouwer, J.W.M.; Nederbragt, G.W.; Verberg, G.W., Viscosity data of organic liquids, Appl. Sci. Res., Sect. A, 1950, 2, 249. [all data]

Mazee, 1948
Mazee, W.M., Some properties of hydrocarbons having more than twenty carbon atoms, Recl. Trav. Chim. Pays-Bas, 1948, 67, 197-213. [all data]

Hetling and Shchekin, 1943
Hetling, V.A.; Shchekin, V.V., Preparation of Certain High Molecular Hydrocarbons, Zh. Obshch. Khim., 1943, 13, 717. [all data]

Larsen, Thorpe, et al., 1942
Larsen, R.G.; Thorpe, R.E.; Armfield, F.A., Oxidation Characteristics of Pure Hydrocarbons, Ind. Eng. Chem., 1942, 34, 183. [all data]

Dykyj, Svoboda, et al., 1999
Dykyj, J.; Svoboda, J.; Wilhoit, R.C.; Frenkel, M.L.; Hall, K.R., Vapor Pressure of Chemicals: Part A. Vapor Pressure and Antoine Constants for Hydrocarbons and Sulfur, Selenium, Tellurium and Hydrogen Containing Organic Compounds, Springer, Berlin, 1999, 373. [all data]


Notes

Go To: Top, Phase change data, Mass spectrum (electron ionization), References