Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

Stannane, cyclohexyltrimethyl-


Gas phase ion energetics data

Go To: Top, Mass spectrum (electron ionization), Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: Sharon G. Lias, Rhoda D. Levin, and Sherif A. Kafafi

Ionization energy determinations

IE (eV) Method Reference Comment
8.57PEHosomi and Traylor, 1975Vertical value

Mass spectrum (electron ionization)

Go To: Top, Gas phase ion energetics data, Gas Chromatography, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Spectrum

Notice: This spectrum may be better viewed with a Javascript and HTML 5 enabled browser.

Mass spectrum
For Zoom
1.) Enter the desired X axis range (e.g., 100, 200)
2.) Check here for automatic Y scaling
3.) Press here to zoom

Additional Data

View image of digitized spectrum (can be printed in landscape orientation).

View spectrum image in SVG format.

Download spectrum in JCAMP-DX format.

Owner NIST Mass Spectrometry Data Center
Collection (C) 2014 copyright by the U.S. Secretary of Commerce
on behalf of the United States of America. All rights reserved.
Origin M.GEILEN UNIVERSITE LIBRE DE BRUXELLES, BELGIUM
NIST MS number 12075

All mass spectra in this site (plus many more) are available from the NIST/EPA/NIH Mass Spectral Library. Please see the following for information about the library and its accompanying search program.


Gas Chromatography

Go To: Top, Gas phase ion energetics data, Mass spectrum (electron ionization), References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Kovats' RI, non-polar column, isothermal

View large format table.

Column type Active phase Temperature (C) I Reference Comment
PackedApiezon L190.1208.Putnam and Pu, 1965Celite; Column length: 1. m

Van Den Dool and Kratz RI, non-polar column, temperature ramp

View large format table.

Column type Active phase I Reference Comment
PackedApiezon L1160.Putnam and Pu, 1965, 2Celite, 10. K/min; Column length: 3. m; Tstart: 60. C
PackedApiezon L1168.Putnam and Pu, 1965, 2Celite, 15. K/min; Column length: 3. m; Tstart: 60. C
PackedApiezon L1157.Putnam and Pu, 1965, 2Celite, 6. K/min; Column length: 3. m; Tstart: 60. C

References

Go To: Top, Gas phase ion energetics data, Mass spectrum (electron ionization), Gas Chromatography, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Hosomi and Traylor, 1975
Hosomi, A.; Traylor, T.G., Studies of interactions of adjacent carbon-metal «sigma» bonds by photoelectron spectroscopy, J. Am. Chem. Soc., 1975, 97, 3682. [all data]

Putnam and Pu, 1965
Putnam, R.C.; Pu, H., Retention indices of organotins, J. Gas Chromatogr., 1965, 3, 5, 160-164, https://doi.org/10.1093/chromsci/3.5.160 . [all data]

Putnam and Pu, 1965, 2
Putnam, R.C.; Pu, H., Retention indices of organotins (II), J. Gas Chromatogr., 1965, 3, 9, 289-293, https://doi.org/10.1093/chromsci/3.9.289 . [all data]


Notes

Go To: Top, Gas phase ion energetics data, Mass spectrum (electron ionization), Gas Chromatography, References