Diethyl sulfide

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30CP Sil 5 CBPolydimethyl siloxanesSE-52OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.
Column length (m)  50. 100.50.
Carrier gas  He  Hydrogen
Substrate      
Column diameter (mm)  0.32 0.500.32
Phase thickness (μm)  1.2   
Program not specified33C (16.5min) => 2C/min => 160C => 20C/min => 200C (9min)not specifiednot specifiednot specified
I 690.698.693.704.683.
ReferenceVinogradov, 2004Gijs, Piraprez, et al., 2000Zenkevich, 1998van Langenhove and Schamp, 1986Waggott and Davies, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type Capillary
Active phase OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.
Column length (m) 50.
Carrier gas Hydrogen
Substrate  
Column diameter (mm) 0.32
Phase thickness (μm)  
Program not specified
I 685.
ReferenceWaggott and Davies, 1984
Comment MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Vinogradov, 2004
Vinogradov, B.A., Production, composition, properties and application of essential oils, 2004, retrieved from http://viness.narod.ru. [all data]

Gijs, Piraprez, et al., 2000
Gijs, L.; Piraprez, G.; Perpète, P.; Spinnler, E.; Collin, S., Retention of sulfur flavours by food matrix and determination of sensorial data independent of the medium composition, Food Chem., 2000, 69, 3, 319-330, https://doi.org/10.1016/S0956-7135(99)00111-5 . [all data]

Zenkevich, 1998
Zenkevich, I.G., The Principle of Structural Analogy in the Calculation of Gas Chromatographic Retention Indices using Physico-Chemical Constants of Organic Compounds, Zh. Anal. Khim. (Rus.), 1998, 53, 1, 43-49. [all data]

van Langenhove and Schamp, 1986
van Langenhove, H.; Schamp, N., Identification of Volatiles in the Head Space of Acid-Treated Phosphate Rock by Gas Chromatography-Mass Spectromety, J. Chromatogr., 1986, 351, 65-75, https://doi.org/10.1016/S0021-9673(01)83473-7 . [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References