Dialuminum


Gas Phase Heat Capacity (Shomate Equation)

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cp° = A + B*t + C*t2 + D*t3 + E/t2
H° − H°298.15= A*t + B*t2/2 + C*t3/3 + D*t4/4 − E/t + F − H
S° = A*ln(t) + B*t + C*t2/2 + D*t3/3 − E/(2*t2) + G
    Cp = heat capacity (J/mol*K)
    H° = standard enthalpy (kJ/mol)
    S° = standard entropy (J/mol*K)
    t = temperature (K) / 1000.

View table.

Temperature (K) 298. - 1400.1400. - 6000.
A 44.5085636.79740
B 7.1323390.736635
C -15.698580.293771
D 6.284242-0.023379
E -0.6213414.461483
F 471.4573483.5867
G 282.3715285.3103
H 487.0176487.0176
ReferenceChase, 1998Chase, 1998
Comment Data last reviewed in June, 1979 Data last reviewed in June, 1979

Notice: A plot could not be displayed here becuse plotting data currently requires a JavaScript and HTML 5 canvas enabled browser.


References

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chase, 1998
Chase, M.W., Jr., NIST-JANAF Themochemical Tables, Fourth Edition, J. Phys. Chem. Ref. Data, Monograph 9, 1998, 1-1951. [all data]


Notes

Go To: Top, Gas Phase Heat Capacity (Shomate Equation), References