Benzo(b)fluorene


Lee's RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase 5 % Phenyl methyl siloxane5 % Phenyl methyl siloxaneHP-5DB-5MSDB-5MS
Column length (m)   30.30.30.
Carrier gas   Helium  
Substrate      
Column diameter (mm)   0.250.250.25
Phase thickness (μm)   0.250.50.5
Tstart (C) 50.80.50.40.40.
Tend (C) 250.300.310.310.310.
Heat rate (K/min) 2.8.6.10.4.
Initial hold (min)  2.1.51.1.
Final hold (min)  10.10.  
I 369.39368.90369.16368.66368.93
ReferenceSkrbic and Onjia, 2006Skrbic and Onjia, 2006Pedersen, Durant, et al., 2005Chen, Keeran, et al., 2002Chen, Keeran, et al., 2002
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PTE-5HP-5HP-5SE-52SPB-5
Column length (m) 30.30.30.30.30.
Carrier gas      
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm) 0.250.250.25  
Tstart (C) 60.50.50.40.40.
Tend (C) 300.280.280.300.300.
Heat rate (K/min) 8.4.4.4.4.
Initial hold (min) 1.52.2.2.2.
Final hold (min) 12.520.20.20. 
I 369.08368.98369.28368.40369.0
ReferenceWang, Jia, et al., 2000Piao, Chu, et al., 1999Piao, Chu, et al., 1999Shaogang and Xiaobai, 1994Knobloch and Engewald, 1993
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase SE-54SE-52DB-5DB-5Methyl Silicone
Column length (m) 20.25.30.30. 
Carrier gas He  He 
Substrate      
Column diameter (mm) 0.220.250.250.25 
Phase thickness (μm) 0.20 0.25  
Tstart (C) 50.130.40.90.100.
Tend (C) 300.260.280.325.275.
Heat rate (K/min) 4.3.4.4.2.
Initial hold (min)   2.  
Final hold (min)   5.  
I 368.74368.97369.05369.70365.78
ReferenceGuillén, Blanco, et al., 1989Hasegawa, Muragishi, et al., 1988Wise, Benner, et al., 1988Tong, Centen, et al., 1985Shlyakhov, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase SE-52SE-52
Column length (m) 20.12.
Carrier gas H2He
Substrate   
Column diameter (mm) 0.300.3
Phase thickness (μm) 0.250.34
Tstart (C) 40.50.
Tend (C) 265.250.
Heat rate (K/min) 4.2.
Initial hold (min) 2. 
Final hold (min)   
I 369.40369.39
ReferenceVassilaros, Kong, et al., 1982Lee, Vassilaros, et al., 1979
Comment MSDC-RI MSDC-RI

References

Go To: Top, Lee's RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Skrbic and Onjia, 2006
Skrbic, B.; Onjia, A., Prediction of Lee Retention Indices of Polycyclic Aromatic Hydrocarbons by Artificial Neural Networks, J. Chromatorg. A, 2006, 1108, 2, 279-284, https://doi.org/10.1016/j.chroma.2006.01.080 . [all data]

Pedersen, Durant, et al., 2005
Pedersen, D.U.; Durant, J.L.; Taghizadeh, K.; Hemond, H.F.; Lafleur, A.L.; Cass, G.R., Human cell mutagenes in respirable airborne particles from the Northeastern United States. 2. Quantification of mutagenes and other organic compounds., Environ. Sci. Technol., 2005, 39, 24, 9547-9560, https://doi.org/10.1021/es050886c . [all data]

Chen, Keeran, et al., 2002
Chen, P.H.; Keeran, W.S.; Van Ausdale, W.A.; Schindler, D.R.; Roberts, D.W., Application of Lee retention indices to the confirmation of tentatively identified compounds from GC/MS analysis of environmental samples, Technical paper, Analytical Services Division, Environmental ScienceEngineering, Inc, PO Box 1703, Gainesville, FL 32602, 2002, 11. [all data]

Wang, Jia, et al., 2000
Wang, J.; Jia, C.R.; Wong, C.K.; Wong, P.K., Characterization of polycyclic aromatic hydrocarbons created in lubricating oils, Water Air Soil Poll., 2000, 120, 3/4, 381-396, https://doi.org/10.1023/A:1005251618062 . [all data]

Piao, Chu, et al., 1999
Piao, M.; Chu, S.; Zheng, M.; Xu, X., Characterization of the combustion products of polyethylene, Chemosphere, 1999, 39, 9, 1497-1512, https://doi.org/10.1016/S0045-6535(99)00054-5 . [all data]

Shaogang and Xiaobai, 1994
Shaogang, C.; Xiaobai, X., System for calculating the linear temperature-programmed retention indices of polycylic aromatic compounds, J. Hi. Res. Chromatogr., 1994, 17, 5, 339-342, https://doi.org/10.1002/jhrc.1240170511 . [all data]

Knobloch and Engewald, 1993
Knobloch, T.; Engewald, W., Identification of some polar polycyclic compounds in emissions from brown-coal-fired residential stoves, J. Hi. Res. Chromatogr., 1993, 16, 4, 239-242, https://doi.org/10.1002/jhrc.1240160407 . [all data]

Guillén, Blanco, et al., 1989
Guillén, M.D.; Blanco, J.; Bermejo, J.; Blanco, C.G., Temperature programmed retention indices of some PAHs on Capillary columns coated with OV-1701 and SE-54, J. Hi. Res. Chromatogr., 1989, 12, 8, 552-554, https://doi.org/10.1002/jhrc.1240120816 . [all data]

Hasegawa, Muragishi, et al., 1988
Hasegawa, K.; Muragishi, T.; Usami, S., Component analysis of coal-derivated heavy oil. Analysis of carcinogenic components in neutral nonpolar fractions, Nippon Kagaku Kaishi, 1988, 3, 3, 311-320, https://doi.org/10.1246/nikkashi.1988.311 . [all data]

Wise, Benner, et al., 1988
Wise, S.A.; Benner, B.A.; Byrd, G.D.; Chesler, S.N.; Rebbert, R.E.; Schantz, M.M., Determination of polycyclic aromatic hydrocarbons in a coal tar standard reference material, Anal. Chem., 1988, 60, 9, 887-894, https://doi.org/10.1021/ac00160a012 . [all data]

Tong, Centen, et al., 1985
Tong, H.Y.; Centen, J.D.; Karasek, F.W.; Jellum, E.; Helland, P., Identification of Trace Organic Compounds in Dimethyl Sulphoxide Solution Using High-Performance Liquid Chromatography and Gas Chromatography-Mass Spectrometry, J. Chromatogr., 1985, 324, 373-383, https://doi.org/10.1016/S0021-9673(01)81336-4 . [all data]

Shlyakhov, 1984
Shlyakhov, A.F., Gas chromatography in organic geochemistry, Nedra, Moscow, 1984, 221. [all data]

Vassilaros, Kong, et al., 1982
Vassilaros, D.L.; Kong, R.C.; Later, D.W.; Lee, M.L., Linear retention index system for polycyclic aromatic compounds. Critical evaluation and additional indices, J. Chromatogr., 1982, 252, 1-20, https://doi.org/10.1016/S0021-9673(01)88394-1 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]


Notes

Go To: Top, Lee's RI, non-polar column, temperature ramp, References