Benzene, 2-propenyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polymethylsiloxane, (PMS-20000)Polydimethyl siloxanesMethyl SiliconeDB-1OV-1, SE-30, Methyl silicone, SP-2100, OV-101, DB-1, etc.
Column length (m)    60.50.
Carrier gas     Hydrogen
Substrate      
Column diameter (mm)    0.320.32
Phase thickness (μm)    0.25 
Program not specifiednot specifiednot specifiednot specifiednot specified
I 933.930.930.928.929.
ReferenceCornwell and Cordano, 2003Zenkevich and Chupalov, 1996Zenkevich, 1995Ciccioli, Cecinato, et al., 1994Waggott and Davies, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Cornwell and Cordano, 2003
Cornwell, E.; Cordano, G., Nueva proposicion para predecir datos de retencion obtenidos mediante cromatografia de gases de hidrocarburos derivados de las naftas, Revista de la Sociedad Quimica de Mexico, 2003, 47, 1, 38-43. [all data]

Zenkevich and Chupalov, 1996
Zenkevich, I.G.; Chupalov, A.A., New Possibilities of Chromato Mass Pectrometric Identification of Organic Compounds Using Increments of Gas Chromatographic Retention Indices of Molecular Structural Fragments, Zh. Org. Khim. (Rus.), 1996, 32, 5, 656-666. [all data]

Zenkevich, 1995
Zenkevich, I.G., Calculation of Gas-Chromatographic Retention Indices from Physico-Chemical Constants of Organic Compounds, Z. Anal. Chem., 1995, 50, 10, 1048-1056. [all data]

Ciccioli, Cecinato, et al., 1994
Ciccioli, P.; Cecinato, A.; Brancaleoni, E.; Brachetti, A.; Frattoni, M.; Sparapani, R., Composition and Distribution of Polar and Non-Polar VOCs in Urban, Rural, Forest and Remote Areas, Eur Commission EUR, 1994, 549-568. [all data]

Waggott and Davies, 1984
Waggott, A.; Davies, I.W., Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References