Pyrazine
- Formula: C4H4N2
- Molecular weight: 80.0880
- IUPAC Standard InChIKey: KYQCOXFCLRTKLS-UHFFFAOYSA-N
- CAS Registry Number: 290-37-9
- Chemical structure:
This structure is also available as a 2d Mol file or as a computed 3d SD file
The 3d structure may be viewed using Java or Javascript. - Other names: p-Diazine; Paradiazine; Piazine; 1,4-Diazabenzene; 1,4-Diazine
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Data at other public NIST sites:
- Options:
Data at NIST subscription sites:
NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.
Normal alkane RI, polar column, custom temperature program
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | DB-Wax | DB-Wax | HP-Innowax | HP-Innowax | Innowax |
Column length (m) | 30. | 30. | 60. | 60. | 30. |
Carrier gas | Hydrogen | Hydrogen | Helium | Helium | Helium |
Substrate | |||||
Column diameter (mm) | 0.25 | 0.25 | 0.32 | 0.32 | 0.25 |
Phase thickness (μm) | 0.25 | 0.25 | 0.25 | 0.25 | 0.50 |
Program | 44 0C 3 0C/min -> 170 0C 8 0C/min -> 250 0C | not specified | 40 0C (5 min) 4 0C/min -> 60 0C (5 min) 8 0C/min -> 250 0C (3 min) | not specified | 40 0C (2 min) 10 0C/min -> 100 0C 3 0C/min -> 160 0C 5 0C/min -> 260 0C (10 min) |
I | 1212. | 1194. | 1214. | 1196. | 1222. |
Reference | Gonzalez-Rios, Suarez-Quiroz, et al., 2007 | Gonzalez-Rios, Suarez-Quiroz, et al., 2007 | Viegas and Bassoli, 2007 | Viegas and Bassoli, 2007 | Ito and Mori, 2004 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary | Capillary | Capillary | Capillary | Capillary |
---|---|---|---|---|---|
Active phase | Carbowax 20M | CP-Wax 52CB | DB-Wax | Carbowax 20M | Carbowax 20M |
Column length (m) | 50. | ||||
Carrier gas | |||||
Substrate | |||||
Column diameter (mm) | 0.32 | ||||
Phase thickness (μm) | 1.2 | ||||
Program | not specified | 40C(10min) => 3C/min => 190C => 10C/min => 250C(5min) | not specified | not specified | not specified |
I | 1194. | 1218. | 1224. | 1179. | 1194. |
Reference | Vinogradov, 2004 | Muresan, Eillebrecht, et al., 2000 | Peng, Yang, et al., 1991 | Mihara and Masuda, 1987 | Shibamoto, 1987 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Capillary |
---|---|
Active phase | Carbowax 400, Carbowax 20M, Carbowax 1540, Carbowax 4000, Superox 06, PEG 20M, etc. |
Column length (m) | 50. |
Carrier gas | Hydrogen |
Substrate | |
Column diameter (mm) | 0.32 |
Phase thickness (μm) | |
Program | not specified |
I | 1196. |
Reference | Waggott and Davies, 1984 |
Comment | MSDC-RI |
References
Go To: Top, Normal alkane RI, polar column, custom temperature program, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Gonzalez-Rios, Suarez-Quiroz, et al., 2007
Gonzalez-Rios, O.; Suarez-Quiroz, M.L.; Boulanger, R.; Barel, M.; Guyot, B.; Guiraud, J.-P.; Schorr-Galindo, S.,
Impact of ecological post-harvest processing of coffee aroma: II Roasted coffee.,
J. Food Composition Analysis, 2007, 20, 3-4, 297-307, https://doi.org/10.1016/j.jfca.2006.12.004
. [all data]
Viegas and Bassoli, 2007
Viegas, M.C.; Bassoli, D.G.,
Utilizacao do indice de retencao linear para caracterizacao de compostos volateis em cafe soluvel utilizando GC-MS e coluna HP-Innowax,
Quim. Nova, 2007, 30, 8, 2031-2034, https://doi.org/10.1590/S0100-40422007000800040
. [all data]
Ito and Mori, 2004
Ito, K.; Mori, M.,
Formation of pyrazines in aqueous maltose/glucose/fructose-glutamide model systems upon heating at below 100 0C,
Food Sci. Technol. Res., 2004, 10, 2, 199-204, https://doi.org/10.3136/fstr.10.199
. [all data]
Vinogradov, 2004
Vinogradov, B.A.,
Production, composition, properties and application of essential oils, 2004, retrieved from http://viness.narod.ru. [all data]
Muresan, Eillebrecht, et al., 2000
Muresan, S.; Eillebrecht, M.A.J.L.; de Rijk, T.C.; de Jonge, H.G.; Leguijt, T.; Nijhuis, H.H.,
Aroma profile development of intermediate chocolate products. I. Volatile constituents of block-milk,
Food Chem., 2000, 68, 2, 167-174, https://doi.org/10.1016/S0308-8146(99)00171-5
. [all data]
Peng, Yang, et al., 1991
Peng, C.T.; Yang, Z.C.; Ding, S.F.,
Prediction of rentention idexes. II. Structure-retention index relationship on polar columns,
J. Chromatogr., 1991, 586, 1, 85-112, https://doi.org/10.1016/0021-9673(91)80028-F
. [all data]
Mihara and Masuda, 1987
Mihara, S.; Masuda, H.,
Correlation between molecular structures and retention indices of pyrazines,
J. Chromatogr., 1987, 402, 309-317, https://doi.org/10.1016/0021-9673(87)80029-8
. [all data]
Shibamoto, 1987
Shibamoto, T.,
Retention Indices in Essential Oil Analysis
in Capillary Gas Chromatography in Essential Oil Analysis, Sandra, P.; Bicchi, C., ed(s)., Hutchig Verlag, Heidelberg, New York, 1987, 259-274. [all data]
Waggott and Davies, 1984
Waggott, A.; Davies, I.W.,
Identification of organic pollutants using linear temperature programmed retention indices (LTPRIs) - Part II, 1984, retrieved from http://dwi.defra.gov.uk/research/completed-research/reports/dwi0383.pdf. [all data]
Notes
Go To: Top, Normal alkane RI, polar column, custom temperature program, References
- Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.