Cyclopentane

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101SE-54Methyl SiliconeOV-101OV-101
Column length (m) 51.40.74.6  
Carrier gas N2N2N2  
Substrate      
Column diameter (mm) 0.250.250.28  
Phase thickness (μm)      
Temperature (C) 40.50.50.50.70.
I 565.571.566.566.569.
ReferenceLi and Deng, 1998Xieyun, Maoqi, et al., 1996N/AWu and Lu, 1984Wu and Lu, 1984
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedCapillary
Active phase SynachromSynachromSqualane
Column length (m) 1.51.5150.
Carrier gas HeliumHeliumHe
Substrate Synachrom (60-80 mesh)Synachrom (60-80 mesh) 
Column diameter (mm)   0.35
Phase thickness (μm)    
Temperature (C) 150.150.86.
I 520.524.560.
ReferenceDufka, Malinsky, et al., 1971Dufka, Malinsky, et al., 1971Vigdergauz and Martynov, 1971
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Li and Deng, 1998
Li, H.; Deng, C., Qualitative analysis of light components of gasoline cracking using Kovats retention indices, J. Instrumental Analysis, 1998, 17, 1, 67-69. [all data]

Xieyun, Maoqi, et al., 1996
Xieyun, H.; Maoqi, C.; Shiyan, Y., Gas Chromatographic analysis during the process of heptaldehyde production using 1-hexene, Chin. J. Chromatogr., 1996, 14, 4, 291-293. [all data]

Wu and Lu, 1984
Wu, J.; Lu, W., Kovats indices of C4-C10 hydrocarbons in apolar quartz capillary OV-101, Chin. J. Chromatogr., 1984, 1, 1, 11-17. [all data]

Dufka, Malinsky, et al., 1971
Dufka, O.; Malinsky, J.; Vladyka, J., Sorpcni materialy pro plynovou chromatographii - III, Chemicky promysl., 1971, 21/46, 9, 459-463. [all data]

Vigdergauz and Martynov, 1971
Vigdergauz, M.S.; Martynov, A.A., Some applications of the gas chromatographic linear retention indices, Chromatographia, 1971, 4, 10, 463-467, https://doi.org/10.1007/BF02268816 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, isothermal, References