2-Hexene, 2-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, custom temperature program

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Methyl SiliconePolydimethyl siloxaneMethyl SiliconeOV-1OV-1
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Program not specifiednot specifiednot specifiednot specifiednot specified
I 692.691.699.701.702.
ReferenceChen and Feng, 2007Junkes, Castanho, et al., 2003Zenkevich, 2000Zhu and He, 1999Zhu and He, 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase SE-54SE-54Methyl SiliconeMethyl Silicone
Column length (m)   115.115.
Carrier gas     
Substrate     
Column diameter (mm)   0.200.20
Phase thickness (μm)   0.300.30
Program not specifiednot specifiednot specifiednot specified
I 704.704.691.691.
ReferenceZhu and He, 1999Zhu and He, 1999Meng and Liu, 1991Meng and Liu, 1991
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Chen and Feng, 2007
Chen, Y.; Feng, C., QSPR study on gas chromatography retention index of some organic pollutants, Comput. Appl. Chem. (China), 2007, 24, 10, 1404-1408. [all data]

Junkes, Castanho, et al., 2003
Junkes, B.S.; Castanho, R.D.M.; Amboni, C.; Yunes, R.A.; Heinzen, V.E.F., Semiempirical Topological Index: A Novel Molecular Descriptor for Quantitative Structure-Retention Relationship Studies, Internet Electronic Journal of Molecular Design, 2003, 2, 1, 33-49. [all data]

Zenkevich, 2000
Zenkevich, I.G., Mutual Correlation between Gas Chromatographic Retention Indices of Unsaturated and Saturated Hydrocarbons found by Molecular Dynamics, Z. Anal. Chem., 2000, 55, 10, 1091-1097. [all data]

Zhu and He, 1999
Zhu, X.; He, L., Derivation of isothermal retention indices from a retention values under multiple-ramp temperature-programmed conditions, J. Instrum. Anal. (Chinese), 1999, 18, 6, 10-12. [all data]

Meng and Liu, 1991
Meng, W.; Liu, C., Gas chromatographic analysis of alkene imourities in solvent naphtha, China Synth. Rubber Ind., 1991, 14, 2, 109-111. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, custom temperature program, References


Copyright for NIST Standard Reference Data is governed by the Standard Reference Data Act.