1-Tridecene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneDB-1DB-1DB-1OV-101
Column length (m)  10.10.30.50.
Carrier gas  HeHe He
Substrate      
Column diameter (mm)  0.250.250.250.25
Phase thickness (μm)  0.250.250.25 
Temperature (C) 100.140.60.240.110.
I 1283.1288.1289.1289.1289.
ReferenceHeinzen, Soares, et al., 1999Beens, Tijssen, et al., 1998Beens, Tijssen, et al., 1998Hanai and Hong, 1989Rang, Kuningas, et al., 1987
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedCapillaryCapillaryCapillary
Active phase OV-101SE-30SqualaneSqualaneSqualane
Column length (m) 50.3.62.  
Carrier gas HeAr   
Substrate  Gas Chrom Q (80-100 mesh)   
Column diameter (mm) 0.25 0.25  
Phase thickness (μm)      
Temperature (C) 110.150.74.100.115.
I 1289.1290.1288.71283.1284.
ReferenceRang, Kuningas, et al., 1987Tiess, 1984Soják, Kraus, et al., 1982Sojak, Hrivnak, et al., 1973Sojak, Hrivnak, et al., 1973
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase SqualaneSqualane
Column length (m)   
Carrier gas   
Substrate   
Column diameter (mm)   
Phase thickness (μm)   
Temperature (C) 130.86.
I 1284.1283.
ReferenceSojak, Hrivnak, et al., 1973Sojak, Hrivnak, et al., 1973
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Heinzen, Soares, et al., 1999
Heinzen, V.E.F.; Soares, M.F.; Yunes, R.A., Semi-empirical topological method for the prediction of the chromatographic retention of cis- and trans-alkene isomers and alkanes, J. Chromatogr. A, 1999, 849, 2, 495-506, https://doi.org/10.1016/S0021-9673(99)00530-0 . [all data]

Beens, Tijssen, et al., 1998
Beens, J.; Tijssen, R.; Blomberg, J., Prediction of comprehensive two-dimensional gas chromatographic separations. A theoretical and practical exercise, J. Chromatogr. A, 1998, 822, 2, 233-251, https://doi.org/10.1016/S0021-9673(98)00649-9 . [all data]

Hanai and Hong, 1989
Hanai, T.; Hong, C., Structure-retention correlation in CGC, J. Hi. Res. Chromatogr., 1989, 12, 5, 327-332, https://doi.org/10.1002/jhrc.1240120517 . [all data]

Rang, Kuningas, et al., 1987
Rang, S.; Kuningas, K.; Strenze, T.; Orav, A.; Eisen, O., Retention and Thermodynamics of Solution of n-Alkenes in OV-101, J. Chromatogr., 1987, 406, 75-80, https://doi.org/10.1016/S0021-9673(00)94018-4 . [all data]

Tiess, 1984
Tiess, D., Gaschromatographische Retentionsindices von 125 leicht- bis mittelflüchtigen organischen Substanzen toxikologisch-analytischer Relevanz auf SE-30, Wiss. Z. Wilhelm-Pieck-Univ. Rostock Math. Naturwiss. Reihe, 1984, 33, 6-9. [all data]

Soják, Kraus, et al., 1982
Soják, L.; Kraus, G.; Farkas, P.; Ostovský, I., Hochleistungs-gaschromatographie an flüssigkristall-glaskapillaren. V. Trennung von isomeren n-tridecenen und n-tetradecenen, J. Chromatogr., 1982, 238, 1, 51-57, https://doi.org/10.1016/S0021-9673(00)82710-7 . [all data]

Sojak, Hrivnak, et al., 1973
Sojak, L.; Hrivnak, J.; Majer, P.; Janak, J., Capillary Gas Chromatography of Linear Alkenes on Squalane, Anal. Chem., 1973, 45, 2, 293-302, https://doi.org/10.1021/ac60324a039 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References