Cyclohexane, 1,4-dimethyl-, trans-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Polydimethyl siloxane: CP-Sil 5 CBPetrocol DHPONAHP-5 MSOV-101
Column length (m) 60.100.50.30.50.
Carrier gas HeliumHeliumNitrogenHeliumHelium
Substrate      
Column diameter (mm) 0.250.250.200.250.20
Phase thickness (μm) 1.00.500.500.250.50
Tstart (C) 45.20.35.50.30.
Tend (C) 210.220.200.280.100.
Heat rate (K/min) 3.615.2.4.1.
Initial hold (min) 1.4515.15. 6.
Final hold (min) 2.7230.10.  
I 779.774.779.774.773.
ReferenceBramston-Cook, 2013Supelco, 2012Zhang, Ding, et al., 2009Zhao, Zeng, et al., 2009Orav, Kailas, et al., 1999
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualaneSqualaneSqualane
Column length (m) 100.100.100.100.100.
Carrier gas      
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm)      
Tstart (C)      
Tend (C)      
Heat rate (K/min) 0.10.20.40.60.8
Initial hold (min)      
Final hold (min)      
I 784.6786.1788.4790.2791.7
ReferenceKrupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986Krupcik, Cellar, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPacked
Active phase SqualaneApiezon L
Column length (m) 100.2.
Carrier gas   
Substrate  Chromosorb G-AW-DMCS
Column diameter (mm) 0.25 
Phase thickness (μm)   
Tstart (C)  25.
Tend (C)   
Heat rate (K/min) 1.10.
Initial hold (min)   
Final hold (min)   
I 793.1736.
ReferenceKrupcik, Cellar, et al., 1986Dahlmann, Köser, et al., 1979
Comment MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Bramston-Cook, 2013
Bramston-Cook, R., Kovats indices for C2-C13 hydrocarbons and selected oxygenated/halocarbons with 100 % dimethylpolysiloxane columns, 2013, retrieved from http://lotusinstruments.com/monographs/List .... [all data]

Supelco, 2012
Supelco, CatalogNo. 24160-U, Petrocol DH Columns. Catalog No. 24160-U, 2012, retrieved from http://www.sigmaaldrich.com/etc/medialib/docs/Supelco/Datasheet/1/w97949.Par.0001.File.tmp/w97949.pdf. [all data]

Zhang, Ding, et al., 2009
Zhang, X.; Ding, L.; Sun, Z.; Song, L.; Sun, T., Study on quantitative structure-retention relationships for hydrocarbons in FCC gasoline, Chromatographia, 2009, 70, 3/4, 511-518, https://doi.org/10.1365/s10337-009-1174-0 . [all data]

Zhao, Zeng, et al., 2009
Zhao, C.; Zeng, Y.; Wan, M.; Li, R.; Liang, Y.; Li, C.; Zeng, Z.; Chau, F.-T., Comparative analysis of essential oils from eight herbal medicines with pungent flavor and cool nature by GC-MS and chemometric resolution methods, J. Sep. Sci., 2009, 32, 4, 660-670, https://doi.org/10.1002/jssc.200800484 . [all data]

Orav, Kailas, et al., 1999
Orav, A.; Kailas, T.; Muurisepp, M.; Kann, J., Composition of the oil from waste tires. 1. Fraction boiling at yp to 160 0C, Proc. Estonian Acad. Sci. Chem., 1999, 48, 1, 30-39. [all data]

Krupcik, Cellar, et al., 1986
Krupcik, J.; Cellar, P.; Repka, D.; Garaj, J.; Guiochon, G., Use of Kováts retention indices for characterization of solutes in linear temperature-programmed capillary gas-liquid chromatography, J. Chromatogr., 1986, 351, 111-121, https://doi.org/10.1016/S0021-9673(01)83477-4 . [all data]

Dahlmann, Köser, et al., 1979
Dahlmann, G.; Köser, H.J.K.; Oelert, H.H., Multiple korrelation von retentionsindizes, Chromatographia, 1979, 12, 10, 665-671, https://doi.org/10.1007/BF02302943 . [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References