NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Normal alkane RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-5 MSHP-5C103H208C103H208
Column length (m) 60.30.60.  
Carrier gas HeliumHeliumHeH2H2
Substrate      
Column diameter (mm) 0.250.250.32  
Phase thickness (μm) 0.250.250.250.250.25
Tstart (C) 35.70.30.80.100.
Tend (C) 220.290.260.275.275.
Heat rate (K/min) 10.5.2.5.4.
Initial hold (min) 1. 2.  
Final hold (min) 15.10.28.  
I 1470.1454.1450.71453.1455.
ReferencePiyachaiseth, Jirapakkul, et al., 2011Radulovic, Blagojevic, et al., 2010Leffingwell and Alford, 2005Dumitrescu, Buda, et al., 2000Dumitrescu, Buda, et al., 2000
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillary
Active phase Ultra-1DB-5Ultra-1SE-54
Column length (m) 50.30.25.25.
Carrier gas H2H2HeHe
Substrate     
Column diameter (mm) 0.20.320.320.32
Phase thickness (μm) 0.330.250.25 
Tstart (C) 60.80.80.50.
Tend (C) 300.270.260.250.
Heat rate (K/min) 3.4.3.8.
Initial hold (min)  2. 2.
Final hold (min) 35.5. 12.
I 1422.1447.1403.1438.
ReferenceElizalde-González, Hutfliess, et al., 1996Andersson and Weis, 1994Okumura, 1991Harland, Cumming, et al., 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Piyachaiseth, Jirapakkul, et al., 2011
Piyachaiseth, T.; Jirapakkul, W.; Chaiseri, S., Aroma compounds of flash-fried rice, Kasetsart J. (Nat. Sci.), 2011, 45, 717-729. [all data]

Radulovic, Blagojevic, et al., 2010
Radulovic, N.; Blagojevic, P.; Palic, R., Comparative study of the leaf volatiles of Arctostaphylos uva-ursi (L.) Spreng. and Vaccinium vitis-idaea L. (Ericaceae), Molecules, 2010, 15, 9, 6168-6185, https://doi.org/10.3390/molecules15096168 . [all data]

Leffingwell and Alford, 2005
Leffingwell, J.C.; Alford, E.D., Volatile constituents of Perique tobacco, Electron. J. Environ. Agric. Food Chem., 2005, 4, 2, 899-915. [all data]

Dumitrescu, Buda, et al., 2000
Dumitrescu, V.; Buda, W.; Medvedovici, A., Evaluation of new stationary phases for capillary gas chromatography, Rev. Roum. Chim., 2000, 45, 4, 313-318. [all data]

Elizalde-González, Hutfliess, et al., 1996
Elizalde-González, M.P.; Hutfliess, M.; Hedden, K., Retention index system, adsorption characteristics, and sructure correlations of polycyclic aromatic hydrocarbons in fuels, J. Hi. Res. Chromatogr., 1996, 19, 6, 345-352, https://doi.org/10.1002/jhrc.1240190608 . [all data]

Andersson and Weis, 1994
Andersson, J.T.; Weis, U., Gas Chromatographic Determination of Polycyclic Aromatic Compounds with Fluorinated Analogues as Internal Standards, J. Chromatogr. A, 1994, 659, 1, 151-161, https://doi.org/10.1016/0021-9673(94)85017-8 . [all data]

Okumura, 1991
Okumura, T., retention indices of environmental chemicals on methyl silicone capillary column, Journal of Environmental Chemistry (Japan), 1991, 1, 2, 333-358, https://doi.org/10.5985/jec.1.333 . [all data]

Harland, Cumming, et al., 1986
Harland, B.J.; Cumming, R.I.; Gillings, E., The Kovats indexes of some organic micropollutants on an SE54 capillary column, EUR, I Org. Micropollut. Aquat. Environ., 1986, EUR 10388, 123-127. [all data]


Notes

Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References