Acenaphthylene

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-1DB-1Ultra-1DB-5SE-52
Column length (m)  30.50.30.33.3
Carrier gas  H2H2HeHe
Substrate      
Column diameter (mm)  0.250.320.260.50
Phase thickness (μm)  0.250.520.25 
Tstart (C) 35.35.35.50.50.
Tend (C) 300.259.259.300.320.
Heat rate (K/min) 8.2.2.6.6.
Initial hold (min)    4.5.
Final hold (min)    20. 
I 1460.01408.91409.01456.1426.
ReferenceGautzsch and Zinn, 1996Farkas, Le Quere, et al., 1994Farkas, Le Quere, et al., 1994Rostad and Pereira, 1986Beernaert, 1979
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase SE-52SE-52
Column length (m) 12.12.
Carrier gas HeHe
Substrate   
Column diameter (mm) 0.30.28
Phase thickness (μm) 0.340.17
Tstart (C) 50.50.
Tend (C) 250.250.
Heat rate (K/min) 2.2.
Initial hold (min)   
Final hold (min)   
I 1425.031413.
ReferenceLee, Vassilaros, et al., 1979Lee, Vassilaros, et al., 1979
Comment MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Gautzsch and Zinn, 1996
Gautzsch, R.; Zinn, P., Use of incremental models to estimate the retention indexes of aromatic compounds, Chromatographia, 1996, 43, 3/4, 163-176, https://doi.org/10.1007/BF02292946 . [all data]

Farkas, Le Quere, et al., 1994
Farkas, P.; Le Quere, J.M.; Maarse, H.; Kovac, M., The standard GC retention index library of flavour compounds in Trends in flavour research. Proceedings of the 7th Weurman Flavour Research Symposium, Maarse,H.; van der Heij,D.G., ed(s)., Weurman Flavour Research Symposium, Noordwijkerhout, Netherlands, 1994, 145-149. [all data]

Rostad and Pereira, 1986
Rostad, C.E.; Pereira, W.E., Kovats and Lee retention indices determined by gas chromatography/mass spectrometry for organic compounds of environmental interest, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1986, 9, 6, 328-334, https://doi.org/10.1002/jhrc.1240090603 . [all data]

Beernaert, 1979
Beernaert, H., Gas Chromatographic Analysis of Polyclylic Aromatic Hydrocarbons, J. Chromatogr., 1979, 173, 1, 109-118, https://doi.org/10.1016/S0021-9673(01)80450-7 . [all data]

Lee, Vassilaros, et al., 1979
Lee, M.L.; Vassilaros, D.L.; White, C.M.; Novotny, M., Retention Indices for Programmed-Temperature Capillary-Column Gas Chromatography of Polycyclic Aromatic Hydrocarbons, Anal. Chem., 1979, 51, 6, 768-773, https://doi.org/10.1021/ac50042a043 . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References