Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

NOTICE: Due to scheduled maintenance at our Gaithersburg campus, this site will not be available from 5:00 pm EDT (21:00 UTC) on Friday October 25 until 5:00 pm (21:00 UTC) on Sunday October 27. We apologize for any inconvenience this outage may cause.

cis-Verbenol


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-5HP-5HP-5HP-5
Column length (m) 50.50.50.50.50.
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm) 0.200.200.200.200.20
Phase thickness (mum) 0.330.330.330.330.33
Temperature (C) 100.110.120.130.140.
I 1148.1152.1156.1161.1165.
ReferenceHennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-5HP-5HP-5HP-5
Column length (m) 50.50.50.50.50.
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm) 0.200.200.200.200.20
Phase thickness (mum) 0.330.330.330.110.11
Temperature (C) 150.80.90.100.110.
I 1170.1140.1144.1148.1152.
ReferenceHennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase HP-5HP-5HP-5HP-5HP-5
Column length (m) 50.50.50.50.50.
Carrier gas H2H2H2H2H2
Substrate      
Column diameter (mm) 0.200.200.200.200.20
Phase thickness (mum) 0.110.110.110.110.11
Temperature (C) 120.130.140.150.80.
I 1157.1161.1165.1170.1141.
ReferenceHennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994Hennig and Engewald, 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillary
Active phase HP-5PB-1
Column length (m) 50.42.
Carrier gas H2 
Substrate   
Column diameter (mm) 0.200.32
Phase thickness (mum) 0.11 
Temperature (C) 90.130.
I 1145.1144.
ReferenceHennig and Engewald, 1994Engewald, Knobloch, et al., 1991
Comment MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Hennig and Engewald, 1994
Hennig, P.; Engewald, W., Influence of adsorption effects on retention indices of selected C10-hydroxy compounds at various temperatures, Chromatographia, 1994, 38, 1/2, 93-97, https://doi.org/10.1007/BF02275733 . [all data]

Engewald, Knobloch, et al., 1991
Engewald, W.; Knobloch, T.; Haufe, G.; Muller, M.; Pohris, V., A Novel Method for Terpene Pattern Determination of Essential Oils by Selectivity Tuning in GC, Fresenius' J. Anal. Chem., 1991, 341, 10, 641-643, https://doi.org/10.1007/BF00322279 . [all data]


Notes