Flurazepam
- Formula: C21H23ClFN3O
- Molecular weight: 387.878
- IUPAC Standard InChIKey: SAADBVWGJQAEFS-UHFFFAOYSA-N
- CAS Registry Number: 17617-23-1
- Chemical structure:
This structure is also available as a 2d Mol file - Other names: 2H-1,4-Benzodiazepin-2-one, 7-chloro-1-[2-(diethylamino)ethyl]-5-(2-fluorophenyl)-1,3-dihydro-; 2H-1,4-Benzodiazepin-2-one, 7-chloro-1-[2-(diethylamino)ethyl]-5-(o-fluorophenyl)-1,3-dihydro-; Ro 56901/3; 2H-1,4-Benzodiazepin-2-one, 1,3-dihydro-7-chloro-1-(2-(diethylamino)ethyl)-5-(o-fluorophenyl)-; 7-Chloro-1-(2-(diethylamino)ethyl)-5-(2-fluorophenyl)-1H-1,4-benzodiazepin-2(3H)-one; 7-Chloro-1-[2-(diethylamino)ethyl]-5-(o-fluorophenyl)-1,3-dihydro-2H-1,4-benzodiazepin-2-one; Felmane; Noctosom; Stauroderm; 7-Chloro-1-[2-(diethylamino)ethyl]-5-(2-fluorophenyl)-1,3-dihydro-2H-1,4-benzodiazepin-2-one
- Permanent link for this species. Use this link for bookmarking this species for future reference.
- Information on this page:
- Other data available:
- Options:
Normal alkane RI, non-polar column, temperature ramp
Go To: Top, References, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director
Column type | Packed | Capillary | Capillary | Capillary | Packed |
---|---|---|---|---|---|
Active phase | SE-30 | BP-1 | DB-5 | DB-5 | SE-30 |
Column length (m) | 2. | 15. | 15. | 2. | |
Carrier gas | Nitrogen | He | He | He | |
Substrate | Chromosorb G AW DMCS (80-100 mesh) | Chromosorb W(100-120 mesh) | |||
Column diameter (mm) | 0.25 | 0.25 | |||
Phase thickness (μm) | 0.2 | 0.25 | |||
Tstart (C) | 100. | 100. | 200. | 150. | 200. |
Tend (C) | 300. | 300. | 295. | 260. | 285. |
Heat rate (K/min) | 10. | 10. | 4. | ||
Initial hold (min) | 1. | 2. | |||
Final hold (min) | 4. | 10. | |||
I | 2785. | 2795. | 2744. | 2795. | 2790. |
Reference | MHA, 9999 | MHA, 9999 | Phillips, Logan, et al., 1990 | Zamechnik, Ethier, et al., 1989 | Chiarotti, de Giovanni, et al., 1986 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
Column type | Packed | Packed | Packed | Packed |
---|---|---|---|---|
Active phase | OV-1 | SE-30 | SE-30 | SE-30 |
Column length (m) | 2. | 2. | 2. | 2. |
Carrier gas | Nitrogen | N2 | ||
Substrate | Gas Chrom P | Gas Chrom P | Chromosorb W AW DMS (80-100 mesh) | Chromosorb W AW DMS |
Column diameter (mm) | ||||
Phase thickness (μm) | ||||
Tstart (C) | 150. | 150. | 130. | 130. |
Tend (C) | 300. | 300. | 290. | 290. |
Heat rate (K/min) | 5. | 5. | 8. | 8. |
Initial hold (min) | 2. | 2. | ||
Final hold (min) | 8. | 8. | ||
I | 2805. | 2815. | 2808. | 2808. |
Reference | Marozzi, Gambaro, et al., 1982 | Marozzi, Gambaro, et al., 1982 | Peel and Perrigo, 1976 | Peel and Perrigo, 1975 |
Comment | MSDC-RI | MSDC-RI | MSDC-RI | MSDC-RI |
References
Go To: Top, Normal alkane RI, non-polar column, temperature ramp, Notes
Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.
MHA, 9999
MHA, Directorate of ForensicScience.,
Forensic Toxicology, 9999. [all data]
Phillips, Logan, et al., 1990
Phillips, A.M.; Logan, B.K.; Stafford, D.T.,
Further applications for capillary gas chromatography in routine quantitative toxicological analyses,
J. Hi. Res. Chromatogr., 1990, 13, 11, 754-758, https://doi.org/10.1002/jhrc.1240131106
. [all data]
Zamechnik, Ethier, et al., 1989
Zamechnik, J.; Ethier, J.-C.; Neville, G.A.,
Benzodiazepines- an extensive collection of mass spectra,
J. Can. Soc. Forensic Sci., 1989, 22, 3, 233-259, https://doi.org/10.1080/00085030.1989.10757437
. [all data]
Chiarotti, de Giovanni, et al., 1986
Chiarotti, M.; de Giovanni, N.; Fiori, A.,
Analysis of Benzodiazepines. I. Chromatographic Identification,
J. Chromatogr., 1986, 358, 169-178, https://doi.org/10.1016/S0021-9673(01)90326-7
. [all data]
Marozzi, Gambaro, et al., 1982
Marozzi, E.; Gambaro, V.; Saligari, E.; Mariani, R.; Lodi, F.,
Use of the retention index in gas chromatographic studies of drugs,
J. Anal. Toxicol., 1982, 6, 4, 185-192, https://doi.org/10.1093/jat/6.4.185
. [all data]
Peel and Perrigo, 1976
Peel, H.W.; Perrigo, B.,
A practical gas chromatographic screening procedure for toxicological analysis,
Can. Soc. Forens. Sci. J., 1976, 9, 2, 69-74, https://doi.org/10.1080/00085030.1976.10757247
. [all data]
Peel and Perrigo, 1975
Peel, H.W.; Perrigo, B.,
A practical gas chromatographic screening procedure for toxicological analysis,
Can.Soc.Forens.Sci.J., 1975, 9, 2, 69-74, https://doi.org/10.1080/00085030.1976.10757247
. [all data]
Notes
Go To: Top, Normal alkane RI, non-polar column, temperature ramp, References
- Symbols used in this document:
Tend Final temperature Tstart Initial temperature - Data from NIST Standard Reference Database 69: NIST Chemistry WebBook
- The National Institute of Standards and Technology (NIST) uses its best efforts to deliver a high quality copy of the Database and to verify that the data contained therein have been selected on the basis of sound scientific judgment. However, NIST makes no warranties to that effect, and NIST shall not be liable for any damage that may result from errors or omissions in the Database.
- Customer support for NIST Standard Reference Data products.