Nonanoic acid, methyl ester

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Van Den Dool and Kratz RI, non-polar column, temperature ramp

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryPacked
Active phase CP Sil 8 CBOV-101SE-30DB-1SE-30
Column length (m) 60.50.25.30. 
Carrier gas HeHeHe  
Substrate     Celite
Column diameter (mm) 0.250.250.320.2 
Phase thickness (μm) 0.250.251.0.25 
Tstart (C) 40.140.140.50.75.
Tend (C) 280.  300.228.
Heat rate (K/min) 4.8.8.5. 
Initial hold (min) 2.  2. 
Final hold (min)    5. 
I 1224.1210.71210.71206.1211.
ReferenceElmore, Campo, et al., 2002Golovnya, Syomina, et al., 1997Grigor'eva, Golovnya, et al., 1997Johnson, Urso, et al., 1997van den Dool and Kratz, 1963
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Elmore, Campo, et al., 2002
Elmore, J.S.; Campo, M.M.; Enser, M.; Mottram, D.S., Effect of lipid composition on meat-like model systems containing cysteine, ribose, and polyunsaturated fatty acids, J. Agric. Food Chem., 2002, 50, 5, 1126-1132, https://doi.org/10.1021/jf0108718 . [all data]

Golovnya, Syomina, et al., 1997
Golovnya, R.V.; Syomina, L.A.; Samusenko, A.L., Nonlinear variation of sorption parameters of n-alkane homologs in temperature-programmed gas chromatography (TPGC) and new equation for calculation of retention indices, J. Hi. Res. Chromatogr., 1997, 20, 11, 611-614, https://doi.org/10.1002/jhrc.1240201108 . [all data]

Grigor'eva, Golovnya, et al., 1997
Grigor'eva, D.N.; Golovnya, R.V.; Syomina, L.A., An equation for the calculation of retention indices in temperature-programmed gas chromatography with allowance for the nonlinear variation of the retention parameters of n-alkanes, Russ. Chem. Bull. (Engl. Transl.), 1997, 46, 2, 309-313, https://doi.org/10.1007/BF02494369 . [all data]

Johnson, Urso, et al., 1997
Johnson, C.I.; Urso, A.; Geleta, L., Broad spectrum analysis of municipal and industrial effluents discharged into the Peace, Athabasca and Slave river basins: characterization of effluent samples, 1994 - Volume 1 of 2, Northern River Basins Study Project Report No. 121, Norther River Basins Study, Edmonton, Alberta, 1997, 27. [all data]

van den Dool and Kratz, 1963
van den Dool, H.; Kratz, P. Dec., A generalization of the retention index system including linear temperature programmed gas-liquid partition chromatography, J. Chromatogr., 1963, 11, 463-471, https://doi.org/10.1016/S0021-9673(01)80947-X . [all data]


Notes

Go To: Top, Van Den Dool and Kratz RI, non-polar column, temperature ramp, References