Cyclopentane, 1,1-dimethyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101CP Sil 2SqualaneDB-1PONA
Column length (m)  100.   
Carrier gas    H2H2
Substrate      
Column diameter (mm)  0.25   
Phase thickness (μm)  0.25 0.250.5
Temperature (C) 0.60.25.60.60.
I 665.675.5669.675.9676.0
ReferenceSkrbic, 1997Estel, Mohnke, et al., 1995Hilal, Carreira, et al., 1994Krupcik, Skacani, et al., 1994Krupcik, Skacani, et al., 1994
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase PONADB-1OV-101OV-1OV-1
Column length (m)    25.25.
Carrier gas H2H2H2HeHe
Substrate      
Column diameter (mm)    0.310.31
Phase thickness (μm) 0.51.0.20.520.52
Temperature (C) 60.60.60.45.65.
I 676.8676.1675.8673.3677.4
ReferenceKrupcik, Skacani, et al., 1994Krupcik, Skacani, et al., 1994Krupcik, Skacani, et al., 1994Guan, Kiraly, et al., 1989Guan, Kiraly, et al., 1989
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101SqualaneSqualane
Column length (m)    50.50.
Carrier gas    HeHe
Substrate      
Column diameter (mm)    0.220.22
Phase thickness (μm)      
Temperature (C) 40.60.80.50.70.
I 671.675.679.672.4676.5
ReferenceLaub and Purnell, 1988Laub and Purnell, 1988Laub and Purnell, 1988Lunskii and Paizanskaya, 1988Lunskii and Paizanskaya, 1988
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase NonpolarNonpolarNonpolarOV-101OV-101
Column length (m)    100.100.
Carrier gas      
Substrate      
Column diameter (mm)    0.270.27
Phase thickness (μm)    0.90.9
Temperature (C) 55.60.65.40.50.
I 675.676.677.671.7673.6
ReferenceStoyanov and Dimov, 1987Stoyanov and Dimov, 1987Stoyanov and Dimov, 1987Boneva and Dimov, 1986Boneva and Dimov, 1986
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101OV-101OV-101
Column length (m) 100.100.   
Carrier gas      
Substrate      
Column diameter (mm) 0.270.27   
Phase thickness (μm) 0.90.9   
Temperature (C) 60.70.30.40.50.
I 675.4676.9669.671.673.
ReferenceBoneva and Dimov, 1986Boneva and Dimov, 1986Chien, Furio, et al., 1983Chien, Furio, et al., 1983Chien, Furio, et al., 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101OV-101DB-1DB-1
Column length (m)    60.60.
Carrier gas      
Substrate      
Column diameter (mm)    0.2640.259
Phase thickness (μm)     1.
Temperature (C) 60.70.80.60.60.
I 675.677.679.675.9676.1
ReferenceChien, Furio, et al., 1983Chien, Furio, et al., 1983Chien, Furio, et al., 1983Lubeck and Sutton, 1983Lubeck and Sutton, 1983
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase OV-101OV-101SF-96SqualaneSqualane
Column length (m) 100.55.91.4120.120.
Carrier gas    HeHe
Substrate      
Column diameter (mm) 0.270.270.310.250.25
Phase thickness (μm) 0.200.90.20  
Temperature (C) 50.50.50.100.100.
I 674.674.674.673.2673.2
ReferenceJohansen and Ettre, 1982Johansen and Ettre, 1982Johansen and Ettre, 1982Lulova, Leont'eva, et al., 1976Lulova, Leont'eva, et al., 1976
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SqualaneSqualaneSqualaneSqualaneSqualane
Column length (m) 100.100.100.100.100.
Carrier gas    N2N2
Substrate      
Column diameter (mm) 0.250.250.250.250.25
Phase thickness (μm)      
Temperature (C) 100.60.80.50.70.
I 684.675.679.674.677.
ReferenceDielmann, Schwengers, et al., 1974Dielmann, Schwengers, et al., 1974Dielmann, Schwengers, et al., 1974Rijks and Cramers, 1974Rijks and Cramers, 1974
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)Vacuum Grease Oil (VM-4)
Column length (m)      
Carrier gas      
Substrate      
Column diameter (mm)      
Phase thickness (μm)      
Temperature (C) 35.45.50.58.68.
I 672.674.675.677.680.
ReferenceSidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972Sidorov, Petrova, et al., 1972
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryPackedPackedPackedPacked
Active phase SqualaneVacuum Grease Oil (VM-4)SE-30SqualaneSqualane
Column length (m) 100. 6.115.15.
Carrier gas   N2HeHe
Substrate   Chromosorb WChromosorb PChromosorb P
Column diameter (mm) 0.25  0.250.25
Phase thickness (μm)      
Temperature (C) 70.35.130.27.49.
I 674.672.683.669.674.
ReferenceDimov and Schopov, 1971Sidorov, Ivanova, et al., 1971Mitra and Saha, 1970Hively and Hinton, 1968Hively and Hinton, 1968
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type PackedPackedCapillary
Active phase SqualaneSqualaneSqualane
Column length (m) 15.15. 
Carrier gas HeHe 
Substrate Chromosorb PChromosorb P 
Column diameter (mm) 0.250.25 
Phase thickness (μm)    
Temperature (C) 67.86.70.
I 677.681.677.
ReferenceHively and Hinton, 1968Hively and Hinton, 1968Schomburg, 1966
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Skrbic, 1997
Skrbic, B.D., Unified retention concept -- statistical treatment of Kováts retention index, J. Chromatogr. A, 1997, 764, 2, 257-264, https://doi.org/10.1016/S0021-9673(96)00955-7 . [all data]

Estel, Mohnke, et al., 1995
Estel, D.; Mohnke; Biermans; Rotzsche, The analysis of C4-C11 hydrocarbons in naphtha and reformate with a new apolar fused silica column, J. Hi. Res. Chromatogr., 1995, 18, 7, 403-412, https://doi.org/10.1002/jhrc.1240180703 . [all data]

Hilal, Carreira, et al., 1994
Hilal, S.H.; Carreira, L.A.; Karickhoff, S.W.; Melton, C.M., Estimation of Gas-Liquid Chromatographic Retention Times from Molecular Structure, J. Chromatogr. A, 1994, 662, 2, 269-280, https://doi.org/10.1016/0021-9673(94)80515-6 . [all data]

Krupcik, Skacani, et al., 1994
Krupcik, J.; Skacani, I.; Benicka, E.; Sandra, P., Dependence of gas chromatographic retention data of hydrocarbons on the film thickness of the polydimethylsiloxane stationary phase, Collect. Czech. Chem. Commun., 1994, 59, 11, 2390-2396, https://doi.org/10.1135/cccc19942390 . [all data]

Guan, Kiraly, et al., 1989
Guan, Y.; Kiraly, J.; Rijks, J.A., Interactive retention index database for compound identification in temperature-programmed capillary gas chromatography, J. Chromatogr., 1989, 472, 129-143, https://doi.org/10.1016/S0021-9673(00)94101-3 . [all data]

Laub and Purnell, 1988
Laub, R.J.; Purnell, J.H., Specific retention volumes, retention indices, and family-plot regressions of aliphatic, alicyclic, and aromatic hydrocarbon solutes with OV-101 poly (dimethylsiloxane) stationary phase, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1988, 11, 9, 649-660, https://doi.org/10.1002/jhrc.1240110908 . [all data]

Lunskii and Paizanskaya, 1988
Lunskii, M.Kh.; Paizanskaya, I.L., Identification of hydrocarbons C1-C9 of petrol fractions of oils and condensates in the use of capillary columns with dinonylphthalate, Zh. Anal. Khim., 1988, 43, 127-135. [all data]

Stoyanov and Dimov, 1987
Stoyanov, E.; Dimov, N., Precalculation of the optimum column temperature for gas chromatographic separation of petroleum fractions, Anal. Chim. Acta., 1987, 201, 207-216, https://doi.org/10.1016/S0003-2670(00)85338-6 . [all data]

Boneva and Dimov, 1986
Boneva, S.; Dimov, N., Unified retention index of hydrocarbons separated on dimethylsilicone OV-101, Chromatographia, 1986, 21, 12, 697-700, https://doi.org/10.1007/BF02313682 . [all data]

Chien, Furio, et al., 1983
Chien, C.-F.; Furio, D.L.; Kopecni, M.M.; Laub, R.J., Specific Retention Volumes and Retention Indices of Selected Hydrocarbon Solutes with OV-101 and SP-2100 Polydimethylsiloxane Solvents, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1983, 6, 10, 577-580, https://doi.org/10.1002/jhrc.1240061013 . [all data]

Lubeck and Sutton, 1983
Lubeck, A.J.; Sutton, DL., Kovats retention indices of selected hydrocarbons through C10 on bonded phase fused silica capillaries, J. Hi. Res. Chromatogr. Chromatogr. Comm., 1983, 6, 6, 328-332, https://doi.org/10.1002/jhrc.1240060612 . [all data]

Johansen and Ettre, 1982
Johansen, N.G.; Ettre, L.S., Retention index values of hydrocarbons on open-tubular columns coated with methylsilicone liquid phases, Chromatographia, 1982, 15, 10, 625-630, https://doi.org/10.1007/BF02279488 . [all data]

Lulova, Leont'eva, et al., 1976
Lulova, N.I.; Leont'eva, S.A.; Timofeeva, A.N., Gas-chromatographic method of determination of individual hydrocarbons in catalytic cracking gasolines in Proceedings of All-Union Research Institute on Oil Processes. Vol.18, All-Union Research Institute on Oil Processes, Moscow, 1976, 30-53. [all data]

Dielmann, Schwengers, et al., 1974
Dielmann, G.; Schwengers, D.; Schomburg, G., Gas-chromatographische Retentionsdaten und Strukture chemischer Verbindungen Gesättigte und ungesättigte alkylsubstituierte Cyclopentane und Methylcyclopentane, Chromatographia, 1974, 7, 5, 215-224, https://doi.org/10.1007/BF02321771 . [all data]

Rijks and Cramers, 1974
Rijks, J.A.; Cramers, C.A., High precision capillary gas chromatography of hydrocarbons, Chromatographia, 1974, 7, 3, 99-106, https://doi.org/10.1007/BF02269819 . [all data]

Sidorov, Petrova, et al., 1972
Sidorov, R.I.; Petrova, V.I.; Ivanova, M.P., Qualitative analysis of wide-boiling fraction C5-C10 with capillary chromatography in Processes in chromatographic columns. Vol.17, 1972, 14-25. [all data]

Dimov and Schopov, 1971
Dimov, N.; Schopov, D., Empirische korrektion der physikalisch-chemischen retentionsindexe von kohlenwasserstoffen auf squalan, J. Chromatogr., 1971, 63, 223-228, https://doi.org/10.1016/S0021-9673(01)85634-X . [all data]

Sidorov, Ivanova, et al., 1971
Sidorov, R.I.; Ivanova, M.P.; Petrova, V.I., Temperature dependence of cycloalkane's retention and its using in identification of structure, Gazovaya Khromatografiya, 1971, 15, 18-26. [all data]

Mitra and Saha, 1970
Mitra, G.D.; Saha, N.C., Determination of Retention Indices of Saturated Hydrocarbons by Graphical Methods, J. Chromatogr. Sci., 1970, 8, 2, 95-102, https://doi.org/10.1093/chromsci/8.2.95 . [all data]

Hively and Hinton, 1968
Hively, R.A.; Hinton, R.E., Variation of the retention index with temperature on squalane substrates, J. Gas Chromatogr., 1968, 6, 4, 203-217, https://doi.org/10.1093/chromsci/6.4.203 . [all data]

Schomburg, 1966
Schomburg, G., Gaschromatographische Retentionsdaten und struktur chemischer verbindungen. III. Alkylverzweigte und ungesättigte cyclische Kohlenwasserstoffe, J. Chromatogr., 1966, 23, 18-41, https://doi.org/10.1016/S0021-9673(01)98653-4 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References