Home Symbol which looks like a small house Up Solid circle with an upward pointer in it

Undecane, 5-methyl-

Data at NIST subscription sites:

NIST subscription sites provide data under the NIST Standard Reference Data Program, but require an annual fee to access. The purpose of the fee is to recover costs associated with the development of data collections included in such sites. Your institution may already be a subscriber. Follow the links above to find out more about the data in these sites and their terms of usage.


Kovats' RI, non-polar column, isothermal

Go To: Top, References, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Data compiled by: NIST Mass Spectrometry Data Center, William E. Wallace, director

Column type CapillaryPackedPackedCapillaryCapillary
Active phase OV-1SE-30SE-30SE-30SE-30
Column length (m) 150.6.16.16.16.1
Carrier gas HeN2N2H2H2
Substrate  Chrom WChrom W  
Column diameter (mm) 0.50  3.183.18
Phase thickness (mum)      
Temperature (C) 60.120.130.130.140.
I 1159.1152.1152.1158.1158.
ReferenceNijs and Jacobs, 1981Mitra, Mohan, et al., 1974Mitra, Mohan, et al., 1974Mitra, Mohan, et al., 1974, 2Mitra, Mohan, et al., 1974, 2
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryCapillaryCapillaryCapillary
Active phase SE-30SE-30SE-30SqualaneApiezon L
Column length (m) 6.16.16.150. 
Carrier gas H2H2H2H2 
Substrate      
Column diameter (mm) 3.183.183.180.2 
Phase thickness (mum)      
Temperature (C) 150.160.170.100.100.
I 1156.1157.1158.1155.1152.
ReferenceMitra, Mohan, et al., 1974, 2Mitra, Mohan, et al., 1974, 2Mitra, Mohan, et al., 1974, 2Mitra, Mohan, et al., 1974, 2Rappoport and Gäumann, 1973
Comment MSDC-RI MSDC-RI MSDC-RI MSDC-RI MSDC-RI
Column type CapillaryCapillaryPacked
Active phase SqualaneDC-200SE-30
Column length (m) 100.100.7.9
Carrier gas  He 
Substrate   Diatoport S
Column diameter (mm) 0.250.25 
Phase thickness (mum)    
Temperature (C) 100.100.70.
I 1153.61154.1156.
ReferenceSchomburg and Dielmann, 1973Schomburg and Henneberg, 1968Widmer, 1967
Comment MSDC-RI MSDC-RI MSDC-RI

References

Go To: Top, Kovats' RI, non-polar column, isothermal, Notes

Data compilation copyright by the U.S. Secretary of Commerce on behalf of the U.S.A. All rights reserved.

Nijs and Jacobs, 1981
Nijs, H.H.; Jacobs, P.A., On-Line Single Run Analysis of Effluents from a Fischer-Tropsch Reactor, J. Chromatogr. Sci., 1981, 19, 1, 40-45, https://doi.org/10.1093/chromsci/19.1.40 . [all data]

Mitra, Mohan, et al., 1974
Mitra, G.D.; Mohan, G.; Sinha, A., Advances in the utilization of the retention index system for characterizing hydrocarbons in complex mixtures by gas chromatography, J. Chromatogr., 1974, 99, 215-230, https://doi.org/10.1016/S0021-9673(00)90857-4 . [all data]

Mitra, Mohan, et al., 1974, 2
Mitra, G.D.; Mohan, G.; Sinha, A., Gas chromatographic analysis of complex hydrocarbon mixtures, J. Chromatogr. A, 1974, 91, 633-648, https://doi.org/10.1016/S0021-9673(01)97944-0 . [all data]

Rappoport and Gäumann, 1973
Rappoport, S.; Gäumann, T., 114. L'indice de rétention des alcanes isomères en chromatographie en phase gazeuse, Helv. Chim. Acta, 1973, 56, 3, 1145-1158, https://doi.org/10.1002/hlca.19730560338 . [all data]

Schomburg and Dielmann, 1973
Schomburg, G.; Dielmann, G., Identification by means of retention parameters, J. Chromatogr. Sci., 1973, 11, 3, 151-159, https://doi.org/10.1093/chromsci/11.3.151 . [all data]

Schomburg and Henneberg, 1968
Schomburg, G.; Henneberg, D., Analyse von i-Paraffingemischen aus ?methylene insertion?-bzw. ?methylene-d2 insertion?-Reaktionen mit einer Kombination Capillar-Gas-Chromatographie/Massenspectrometrie, Anal. Chem., 1968, 236, 1, 279-294, https://doi.org/10.1007/BF00503281 . [all data]

Widmer, 1967
Widmer, H., Gas chromatographic identification of hydrocarbons using retention indices, J. Gas Chromatogr., 1967, 5, 10, 506-510, https://doi.org/10.1093/chromsci/5.10.506 . [all data]


Notes

Go To: Top, Kovats' RI, non-polar column, isothermal, References